An ethics-informed computable audit framework for monitoring misdiagnosis risk in AI-assisted diagnosis

Diagnostic AI can misclassify under distribution shift and subgroup imbalance; governance signals are rarely computable at deploy time. We target deployed diagnostic decision-support systems that perform binary classification and output a continuous risk score (preferably a calibrated probability). The audit layer ingests deploy-time streams including features X, model score S, subgroup tag g, and clinician action a, while outcome labels Y may arrive later via adjudication or follow-up. We define a unit-scaled Misdiagnosis Risk Index (MRI-AI) aggregating shift, fairness, calibration, and human-AI interaction; implement a streaming sentinel with starter bands and stop rules; and log signals and actions in an accountability ledger. A minimal simulation emulates device/site drift and imbalance. Outcomes include deploy-time trigger behavior from label-free indicators and delayed updates of label-dependent metrics (overall/worst-group AUC/FPR, ECE/Brier), as well as trigger rate, top-decile error share, and decision-curve net benefit. Using a controlled, scenario-based synthetic stress-test suite (designed to evaluate the audit/monitoring layer rather than to claim clinical performance of a particular diagnostic model), we report both predictive metrics (overall and worst-group AUC/FPR, ECE, and Brier) and alert-centric endpoints (window-level alert rate, time-to-first-trigger, and persistence). The results show that alert burden remains low under stable conditions and increases in a graded and interpretable manner with shift type and severity, supporting scenario-dependent monitoring and risk-tiered governance actions. Temperature scaling improves calibration while preserving rank-based decision behavior, and subgroup disparities remain explicitly auditable. A computable audit layer-MRI-AI + streaming sentinel + ledger-turns fairness and transparency into actionable controls for diagnostic decision support, enabling auditable monitoring and risk-tiered interventions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-06
DOI
https://doi.org/10.1038/s41598-026-46652-1
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An ethics-informed computable audit framework for monitoring misdiagnosis risk in AI-assisted diagnosis

Yi Xin, Yujing Yang, Jia Fu, M Yuan et al.
Scientific Reports
Artificial Intelligence in Healthcare and Education
article

An ethics-informed computable audit framework for monitoring misdiagnosis risk in AI-assisted diagnosis

Yi Xin, Yujing Yang, Jia Fu, M Yuan, Yi-Xiang Wang, Yue Li, Chu Jie Duan
article en

Abstract

Diagnostic AI can misclassify under distribution shift and subgroup imbalance; governance signals are rarely computable at deploy time. We target deployed diagnostic decision-support systems that perform binary classification and output a continuous risk score (preferably a calibrated probability). The audit layer ingests deploy-time streams including features X, model score S, subgroup tag g, and clinician action a, while outcome labels Y may arrive later via adjudication or follow-up. We define a unit-scaled Misdiagnosis Risk Index (MRI-AI) aggregating shift, fairness, calibration, and human-AI interaction; implement a streaming sentinel with starter bands and stop rules; and log signals and actions in an accountability ledger. A minimal simulation emulates device/site drift and imbalance. Outcomes include deploy-time trigger behavior from label-free indicators and delayed updates of label-dependent metrics (overall/worst-group AUC/FPR, ECE/Brier), as well as trigger rate, top-decile error share, and decision-curve net benefit. Using a controlled, scenario-based synthetic stress-test suite (designed to evaluate the audit/monitoring layer rather than to claim clinical performance of a particular diagnostic model), we report both predictive metrics (overall and worst-group AUC/FPR, ECE, and Brier) and alert-centric endpoints (window-level alert rate, time-to-first-trigger, and persistence). The results show that alert burden remains low under stable conditions and increases in a graded and interpretable manner with shift type and severity, supporting scenario-dependent monitoring and risk-tiered governance actions. Temperature scaling improves calibration while preserving rank-based decision behavior, and subgroup disparities remain explicitly auditable. A computable audit layer-MRI-AI + streaming sentinel + ledger-turns fairness and transparency into actionable controls for diagnostic decision support, enabling auditable monitoring and risk-tiered interventions.

Scientific Reports
Shanxi Medical University (CN), Jinzhong University (CN), Shanxi Provincial Cancer Hospital (CN), Shanxi Fenyang Hospital (CN)
Shanxi Medical University
Peace, Justice and strong institutions
Openalex Percentile: Top 9%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.