Direct estimation of activity concentration in regional voxels with application to <sup>177</sup> Lu peptide receptor radionuclide therapy

BACKGROUND: Quantitative SPECT in radionuclide-therapy is limited by partial-volume effects (PVEs). The implementation of regional voxels (r.v.), estimating mean activity concentrations in regions directly from projections, offers a promising alternative for the geometry-specification to reduce PVEs. PURPOSE: Lu-PRRT). METHODS: Lu]Lu-DOTA-TATE with SPECT acquired 1 d p.i. (dataset PB). Activity concentration was estimated from reconstruction with cu.v. and using r.v. for both datasets, with multiple noise realizations for PA using bootstrapping. Organ delineation was performed based on CT using the AI tool TotalSegmentator, and tumor delineation made in cu.v. SPECT images. The estimated activity concentration for kidneys, spleen, and tumors from r.v. was compared to that obtained with cu.v. with and without post-reconstruction PVC. To study the accuracy of activity-concentration estimates, simulations were performed with the SIMIND Monte Carlo program with patient images used as basis. The sensitivity to misalignments between SPECT and CT was also evaluated. RESULTS: For both patient and simulated data, activity concentrations estimated with r.v. are higher than those from cu.v., with comparable standard deviations. Mean relative errors for simulated images from PA relative to simulation input at 1 d p.i. reconstructions with r.v. are (-4.6 ± 1.4) %, (3.0 ± 0.5) %, (0.1 ± 0.5) %, and (5.6 ± 1.2) % for tumor, left kidney, right kidney, and spleen, respectively. Corresponding results for cu.v. with post-reconstruction PVC are (-12.3 ± 2.2) %, (-4.2 ± 0.6) %, (-7.0 ± 0.5) %, and (-2.1 ± 1.1) %. For simulated images based on PB, the mean relative errors obtained for r.v. are (-3.1 ± 3.5) %, (1.2 ± 1.2) %, (-1.7 ± 1.1) %, and (2.3 ± 0.8) %, while for cu.v. with PVC they are (-7.9 ± 6.7) %, (-5.8 ± 1.9) %, (-9.0 ± 1.0) %, and (-0.7 ± 2.6) %. CONCLUSIONS: Lu-PRRT and demonstrates lower sensitivity to misregistration errors. For tumors, r.v. yields lower systematic errors than cu.v. but demonstrates a higher sensitivity to image segmentation errors for volumes below approximately 10 mL.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-04-01
DOI
https://doi.org/10.1002/mp.70424
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct estimation of activity concentration in regional voxels with application to 177 Lu peptide receptor radionuclide therapy

Katarina Sjögreen Gleisner, Johan Gustafsson, Erik Larsson
Medical Physics
Radiopharmaceutical Chemistry and Applications
article

Direct estimation of activity concentration in regional voxels with application to 177 Lu peptide receptor radionuclide therapy

Katarina Sjögreen Gleisner, Johan Gustafsson, Erik Larsson
article en

Abstract

BACKGROUND: Quantitative SPECT in radionuclide-therapy is limited by partial-volume effects (PVEs). The implementation of regional voxels (r.v.), estimating mean activity concentrations in regions directly from projections, offers a promising alternative for the geometry-specification to reduce PVEs. PURPOSE: Lu-PRRT). METHODS: Lu]Lu-DOTA-TATE with SPECT acquired 1 d p.i. (dataset PB). Activity concentration was estimated from reconstruction with cu.v. and using r.v. for both datasets, with multiple noise realizations for PA using bootstrapping. Organ delineation was performed based on CT using the AI tool TotalSegmentator, and tumor delineation made in cu.v. SPECT images. The estimated activity concentration for kidneys, spleen, and tumors from r.v. was compared to that obtained with cu.v. with and without post-reconstruction PVC. To study the accuracy of activity-concentration estimates, simulations were performed with the SIMIND Monte Carlo program with patient images used as basis. The sensitivity to misalignments between SPECT and CT was also evaluated. RESULTS: For both patient and simulated data, activity concentrations estimated with r.v. are higher than those from cu.v., with comparable standard deviations. Mean relative errors for simulated images from PA relative to simulation input at 1 d p.i. reconstructions with r.v. are (-4.6 ± 1.4) %, (3.0 ± 0.5) %, (0.1 ± 0.5) %, and (5.6 ± 1.2) % for tumor, left kidney, right kidney, and spleen, respectively. Corresponding results for cu.v. with post-reconstruction PVC are (-12.3 ± 2.2) %, (-4.2 ± 0.6) %, (-7.0 ± 0.5) %, and (-2.1 ± 1.1) %. For simulated images based on PB, the mean relative errors obtained for r.v. are (-3.1 ± 3.5) %, (1.2 ± 1.2) %, (-1.7 ± 1.1) %, and (2.3 ± 0.8) %, while for cu.v. with PVC they are (-7.9 ± 6.7) %, (-5.8 ± 1.9) %, (-9.0 ± 1.0) %, and (-0.7 ± 2.6) %. CONCLUSIONS: Lu-PRRT and demonstrates lower sensitivity to misregistration errors. For tumors, r.v. yields lower systematic errors than cu.v. but demonstrates a higher sensitivity to image segmentation errors for volumes below approximately 10 mL.

Medical PhysicsVol. 53(4)
Lund University (SE), Skåne University Hospital (SE)
Cancerfonden, Fru Berta Kamprads Stiftelse
Peace, Justice and strong institutions
Openalex Percentile: Top 22%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.