Large-scale experimental study of thermal performance of building-integrated photovoltaic façade in an enclosure fire

Building Integrated Photovoltaic (BIPV) façades play a significant role in enhancing the renewable energy performance and sustainability of modern buildings. However, fire incidents are becoming increasingly common in BIPV systems, yet little is known about the fire performance of BIPV façade in real large-scale fire scenarios. In this work, a total of 16 large-scale fire tests were conducted to investigate the thermal breakage and fallout of BIPV façade in a compartment fire, with a dimension of 1400 × 1400 × 1800 mm 3 . Cadmium telluride and monocrystalline silicon BIPV curtain wall components were selected for this study, with traditional glass included for comparison. Significant differences were observed between PV façade and traditional glass façade, with the former exhibiting self-sustained burning, even after the fire extinction. The types of PV panels significantly impact the breakage and fallout times and behavior, as the new openings caused by PV panel fallout alter the stable ventilation condition and induce more flame ejection, resulting in a significant heat flux compared to control cases without samples. Among the tested configurations, double-glazed PV panels with tempered glass demonstrated the best fire performance and are therefore recommended for BIPV façade design. The experimental results would provide important references for the fire safety design of emerging BIPV high-rise buildings. • The large-scale fire tests of different types of BIPV façades were conducted • Self-sustained burning of interlayers occurred significant, even after the fuel had burnt out • The type of glass panel is a key factor in determining the thermal behavior of PV façade • Interaction between PV panels and compartment fire dynamics was revealed

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2026-04-01
DOI
https://doi.org/10.1016/j.jobe.2026.116033
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Large-scale experimental study of thermal performance of building-integrated photovoltaic façade in an enclosure fire

Dezhi Ran, FengQi Wang, Chengming Xiao, Jie Sun et al.
Journal of Building Engineering
Solar Thermal and Photovoltaic Systems
article

Large-scale experimental study of thermal performance of building-integrated photovoltaic façade in an enclosure fire

Dezhi Ran, FengQi Wang, Chengming Xiao, Jie Sun, Haonan Chen, Yu Wang, Rui Zhou, Chiara Bedon
article en

Abstract

Building Integrated Photovoltaic (BIPV) façades play a significant role in enhancing the renewable energy performance and sustainability of modern buildings. However, fire incidents are becoming increasingly common in BIPV systems, yet little is known about the fire performance of BIPV façade in real large-scale fire scenarios. In this work, a total of 16 large-scale fire tests were conducted to investigate the thermal breakage and fallout of BIPV façade in a compartment fire, with a dimension of 1400 × 1400 × 1800 mm 3 . Cadmium telluride and monocrystalline silicon BIPV curtain wall components were selected for this study, with traditional glass included for comparison. Significant differences were observed between PV façade and traditional glass façade, with the former exhibiting self-sustained burning, even after the fire extinction. The types of PV panels significantly impact the breakage and fallout times and behavior, as the new openings caused by PV panel fallout alter the stable ventilation condition and induce more flame ejection, resulting in a significant heat flux compared to control cases without samples. Among the tested configurations, double-glazed PV panels with tempered glass demonstrated the best fire performance and are therefore recommended for BIPV façade design. The experimental results would provide important references for the fire safety design of emerging BIPV high-rise buildings. • The large-scale fire tests of different types of BIPV façades were conducted • Self-sustained burning of interlayers occurred significant, even after the fuel had burnt out • The type of glass panel is a key factor in determining the thermal behavior of PV façade • Interaction between PV panels and compartment fire dynamics was revealed

Journal of Building EngineeringVol. 124
University of Science and Technology of China (CN), University of Trieste (IT)
National Natural Science Foundation of China, Ministero degli Affari Esteri e della Cooperazione Internazionale
Openalex Percentile: Top 33%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.