Development And Validation Of An RP-HPLC Method For Simultaneous Determination Of Sitagliptin And Valsartan

BACKGROUND: Diabetes mellitus and hypertension are commonly coexisting diseases and combination therapies are required to improve therapeutic outcomes and patient compliance. OBJECTIVES: Current research aims to develop and validate a precise reverse-phase High-Performance Liquid Chromatography (RP-HPLC) method for the concurrent determination of sitagliptin and valsartan. METHODS: For analysis, an Agilent 1260 Infinity II HPLC system provided with a C-18 column was used. The method was validated as per the ICH guidelines. RESULTS: values exceeding 0.99. The limits of detection (LOD) and quantification (LOQ) were calculated as 8.5 ppm and 25.7 ppm for sitagliptin and 7.8 ppm and 23.5 ppm for valsartan, respectively. Recovery studies and robustness confirmed method accuracy and indicated no significant impact from small variations in chromatographic parameters. CONCLUSION: In conclusion, this validated RP-HPLC method is consistent and efficient for compliance with pharmaceutical standards.

Publication Details

Journal
Pakistan Journal of Pharmaceutical Sciences
Published
2026-04-02
DOI
https://doi.org/10.36721/pjps.2026.39.6.165.1
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development And Validation Of An RP-HPLC Method For Simultaneous Determination Of Sitagliptin And Valsartan

Pakistan Journal of Pharmaceutical Sciences
Analytical Methods in Pharmaceuticals
article

Development And Validation Of An RP-HPLC Method For Simultaneous Determination Of Sitagliptin And Valsartan

article en

Abstract

BACKGROUND: Diabetes mellitus and hypertension are commonly coexisting diseases and combination therapies are required to improve therapeutic outcomes and patient compliance. OBJECTIVES: Current research aims to develop and validate a precise reverse-phase High-Performance Liquid Chromatography (RP-HPLC) method for the concurrent determination of sitagliptin and valsartan. METHODS: For analysis, an Agilent 1260 Infinity II HPLC system provided with a C-18 column was used. The method was validated as per the ICH guidelines. RESULTS: values exceeding 0.99. The limits of detection (LOD) and quantification (LOQ) were calculated as 8.5 ppm and 25.7 ppm for sitagliptin and 7.8 ppm and 23.5 ppm for valsartan, respectively. Recovery studies and robustness confirmed method accuracy and indicated no significant impact from small variations in chromatographic parameters. CONCLUSION: In conclusion, this validated RP-HPLC method is consistent and efficient for compliance with pharmaceutical standards.

Pakistan Journal of Pharmaceutical SciencesVol. 39(6)
Openalex Percentile: Top 26%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.