Assessing inter‐observer variability in prostate and GTV segmentation on mpMRI: A comparison between radiation oncologists and AI‐based method

BACKGROUND: Accurate delineation of the prostate and intraprostatic gross tumor volume (GTV) on multiparametric MRI (mpMRI) is critical for radiation therapy planning, particularly for focal dose escalation strategies. However, interpretation of mpMRI can be challenging and prone to inter-observer variability, especially among radiation oncologists (ROs) who may have limited training in prostate MRI interpretation. In addition, because many patients do not undergo diagnostic mpMRI before treatment, radiologist input is often absent during treatment planning, which can compromise accurate GTV delineation. PURPOSE: To evaluate approaches for improving focal prostate GTV delineation on mpMRI for radiotherapy planning, by assessing the impact of radiology reports on ROs contours, and comparing the performance of an automated segmentation tool (AIRC) with radiologists' contours as a potential replacement when radiologist input is unavailable. METHODS: Twenty patients underwent mpMRI at our institution. Delineation of the prostate gland and GTV was performed by ROs in two phases. In the first phase, ROs segmented both structures with access only to biopsy results, indicating positive core locations. In the second phase, they repeated the segmentation with access to the radiology report. AIRC segmented both structures as well, using the same images as made available to the ROs. Lesion detection performance was evaluated using sensitivity and positive predictive value (PPV). Segmentations were compared to consensus contours from two radiologists using the STAPLE algorithm. Similarity metrics computed included Dice similarity coefficient (DSC), Hausdorff distance (HD), distance from center, and relative volume difference. RESULTS: ). AIRC performance was comparable to the ROs' first attempt. CONCLUSIONS: High inter-observer variability in GTV segmentation was observed when ROs lacked access to the radiology report, underscoring the difficulty of mpMRI interpretation. Providing radiology reports and establishing standardized guidelines for mpMRI interpretation may improve segmentation accuracy and consistency. An Automated segmentation tool could facilitate the first step in the planning workflow by assisting ROs in target definition.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2026-04-01
DOI
https://doi.org/10.1002/acm2.70563
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing inter‐observer variability in prostate and GTV segmentation on mpMRI: A comparison between radiation oncologists and AI‐based method

Philippe Dionne, Éric Vigneault, Étienne Ouellet, Ingrid Sidibé et al.
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
article

Assessing inter‐observer variability in prostate and GTV segmentation on mpMRI: A comparison between radiation oncologists and AI‐based method

Philippe Dionne, Éric Vigneault, Étienne Ouellet, Ingrid Sidibé, François Bachand, E. Poulin, Louis Archambault, William Foster, Marie‐Anne Froment, André‐Guy Martin, Jean‐Christophe Roy
article en

Abstract

BACKGROUND: Accurate delineation of the prostate and intraprostatic gross tumor volume (GTV) on multiparametric MRI (mpMRI) is critical for radiation therapy planning, particularly for focal dose escalation strategies. However, interpretation of mpMRI can be challenging and prone to inter-observer variability, especially among radiation oncologists (ROs) who may have limited training in prostate MRI interpretation. In addition, because many patients do not undergo diagnostic mpMRI before treatment, radiologist input is often absent during treatment planning, which can compromise accurate GTV delineation. PURPOSE: To evaluate approaches for improving focal prostate GTV delineation on mpMRI for radiotherapy planning, by assessing the impact of radiology reports on ROs contours, and comparing the performance of an automated segmentation tool (AIRC) with radiologists' contours as a potential replacement when radiologist input is unavailable. METHODS: Twenty patients underwent mpMRI at our institution. Delineation of the prostate gland and GTV was performed by ROs in two phases. In the first phase, ROs segmented both structures with access only to biopsy results, indicating positive core locations. In the second phase, they repeated the segmentation with access to the radiology report. AIRC segmented both structures as well, using the same images as made available to the ROs. Lesion detection performance was evaluated using sensitivity and positive predictive value (PPV). Segmentations were compared to consensus contours from two radiologists using the STAPLE algorithm. Similarity metrics computed included Dice similarity coefficient (DSC), Hausdorff distance (HD), distance from center, and relative volume difference. RESULTS: ). AIRC performance was comparable to the ROs' first attempt. CONCLUSIONS: High inter-observer variability in GTV segmentation was observed when ROs lacked access to the radiology report, underscoring the difficulty of mpMRI interpretation. Providing radiology reports and establishing standardized guidelines for mpMRI interpretation may improve segmentation accuracy and consistency. An Automated segmentation tool could facilitate the first step in the planning workflow by assisting ROs in target definition.

Journal of Applied Clinical Medical PhysicsVol. 27(4)
Hôtel-Dieu de Québec (CA), Centre hospitalier de l'Université Laval (CA), Université Laval (CA)
Good health and well-being
Openalex Percentile: Top 25%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.