Study of Tricuspid Valve Regurgitation by 2D and 3D Echocardiography: Comparison Between Transthoracic and Transesophageal Examination for Screening Interventions

AIM: To compare the accuracy of 2D and 3D tricuspid valve reconstructions of TTE versus TEE for screening patients with TR who are candidates for surgical or transcatheter interventions. METHODS: Consecutive 42 patients with diagnosis of symptomatic and significant TR were enrolled. Each patient underwent a 2D/3D TTE and a 2D/3D TEE on the same day. Parameters for RV dimension and function evaluation were acquired on a 2D examination from the RV focused apical window for TTE and 4 mid-esophageal chambers for TEE. 3D reconstructions were made to visualize the structures and parameters to be studied (tricuspid annulus, leaflets, annulus area, annulus perimeter, valve area). The leaflets gap was obtained from the transgastric view (for TEE) and from 3D reconstructions (for TTE). The GLIDE score (Gap, jet Location, Image quality, chordal structure Density, En-Face TR jet morphology), a simple, five-component score that can predict a successful T-TEER, was calculated for TTE and TEE. RESULTS: TR grade, function and dimension of RV, tricuspid annulus parameters, coaptation gap and total GLIDE-score analyzed at TTE and TEE did not show any statistically difference (p > 0.05) except for the number of leaflets that were better determined by TEE instead of TTE (P < 0,001). CONCLUSIONS: TTE is an excellent initial screening tool for evaluating patients who are candidates for transcatheter repair or surgical intervention for significant TR. However, TEE provides superior visualization of the valve leaflets and should be performed in patients with favorable anatomical characteristics identified on TTE.

Authors

Institutions

Publication Details

Journal
Echocardiography
Published
2026-04-01
DOI
https://doi.org/10.1111/echo.70435
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Tricuspid Valve Regurgitation by 2D and 3D Echocardiography: Comparison Between Transthoracic and Transesophageal Examination for Screening Interventions

Piera Ciaramella, Francesco Candido, Lucrezia Netti, Marco Russo et al.
Echocardiography
Cardiac Valve Diseases and Treatments
article

Study of Tricuspid Valve Regurgitation by 2D and 3D Echocardiography: Comparison Between Transthoracic and Transesophageal Examination for Screening Interventions

Piera Ciaramella, Francesco Candido, Lucrezia Netti, Marco Russo, Sara Monosilio, Giampaolo Luzi, Alice Tolomei, V Maestrini, A G Cammardella, A Pergolini
article en

Abstract

AIM: To compare the accuracy of 2D and 3D tricuspid valve reconstructions of TTE versus TEE for screening patients with TR who are candidates for surgical or transcatheter interventions. METHODS: Consecutive 42 patients with diagnosis of symptomatic and significant TR were enrolled. Each patient underwent a 2D/3D TTE and a 2D/3D TEE on the same day. Parameters for RV dimension and function evaluation were acquired on a 2D examination from the RV focused apical window for TTE and 4 mid-esophageal chambers for TEE. 3D reconstructions were made to visualize the structures and parameters to be studied (tricuspid annulus, leaflets, annulus area, annulus perimeter, valve area). The leaflets gap was obtained from the transgastric view (for TEE) and from 3D reconstructions (for TTE). The GLIDE score (Gap, jet Location, Image quality, chordal structure Density, En-Face TR jet morphology), a simple, five-component score that can predict a successful T-TEER, was calculated for TTE and TEE. RESULTS: TR grade, function and dimension of RV, tricuspid annulus parameters, coaptation gap and total GLIDE-score analyzed at TTE and TEE did not show any statistically difference (p > 0.05) except for the number of leaflets that were better determined by TEE instead of TTE (P < 0,001). CONCLUSIONS: TTE is an excellent initial screening tool for evaluating patients who are candidates for transcatheter repair or surgical intervention for significant TR. However, TEE provides superior visualization of the valve leaflets and should be performed in patients with favorable anatomical characteristics identified on TTE.

EchocardiographyVol. 43(4)
Carlo Forlanini Hospital (IT), Sapienza University of Rome (IT)
Good health and well-being
Openalex Percentile: Top 26%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.