Abstract 2619: Quantitative modeling of autofluorescence and non-specific staining allows for improved cell phenotyping and marker assessment in highly multiplexed immunofluorescence studies.

Abstract While fundamental in cancer diagnostics, immunohistochemistry (IHC) has several significant limitations, including the inability to simultaneously detect multiple markers per slide, which limits true co-expression analysis. In contrast, sequential immunofluorescence (seqIF), a multiplexed protein biomarker detection method, allows for simultaneous detection of multiple markers on a single slide by using antibodies with distinct fluorophores combined with the repeated automated cycles of staining, imaging, and elution. While seqIF has quantitative and scalability advantages over IHC, its use of fluorescence introduces various challenges for downstream computational analysis such as tissue’s autofluorescence and non-specific fluorophore accumulation, which are compound by multiple cycles of staining, imaging and elution. The Lunaphore COMET, a seqIF system, allows for an initial background autofluorescence acquisition at the beginning of the protocol. However, we observed that this single baseline measurement did not account changes in the fluorescence of different regions in various tissue types with subsequent imaging and elution cycles, which significantly affected downstream analysis including cell typing.To further investigate these artifacts, we evaluated both autofluorescent quenching on a variety of tissue types during the imaging cycles as well as the non-specific accumulation of fluorophores in all channels (FITC, TRITC, Cy5, and Cy7). We found that the background autofluorescence decreased with sequential cycles in some, but not all cycles, which led to artificially decreased signal intensity for downstream marker analysis. Additionally, we found that non-specific fluorophore accumulation was channel specific, tissue specific, and subcellular localization specific, further confounding interpretability. Overall, these findings suggest that utilizing a single baseline autofluorescence cycle for background subtraction is insufficient and can lead to significant downstream analytical errors.While performing an additional imaging cycle after each elution cycle and subtracting background accordingly may remedy this problem, it is not always feasible or efficient due to increased time, reagent usage, and file size. We found that a total of 5 imaging cycles post-elution accurately predicted the background fluorescence for 20 cycles using a cell-level cubic spline model (R2 = 0.94). These background signal modeling results are then utilized to calculate background-adjusted marker expression values at a cell level for individual cycles, which improved clustering resolution and interoperability. Overall, we demonstrate issues encountered with autofluorescence in seqIF and present a novel method for mitigating them to improve results. Citation Format: Daria I. Mandel, Anton Luis Villamejor, Anthony Colombo, Simeon Mahov, Akil A. Merchant, Joseph Lownik.. Quantitative modeling of autofluorescence and non-specific staining allows for improved cell phenotyping and marker assessment in highly multiplexed immunofluorescence studies [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 2619.

Authors

Institutions

Publication Details

Journal
Cancer Research
Published
2026-04-03
DOI
https://doi.org/10.1158/1538-7445.am2026-2619
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 2619: Quantitative modeling of autofluorescence and non-specific staining allows for improved cell phenotyping and marker assessment in highly multiplexed immunofluorescence studies.

Anthony Colombo, Joseph Lownik, Daria Mandel, Simeon Mahov et al.
Cancer Research
Advanced Fluorescence Microscopy Techniques
article

Abstract 2619: Quantitative modeling of autofluorescence and non-specific staining allows for improved cell phenotyping and marker assessment in highly multiplexed immunofluorescence studies.

Anthony Colombo, Joseph Lownik, Daria Mandel, Simeon Mahov, Anton Villamejor, Akil A. Merchant
article en

Abstract

Abstract While fundamental in cancer diagnostics, immunohistochemistry (IHC) has several significant limitations, including the inability to simultaneously detect multiple markers per slide, which limits true co-expression analysis. In contrast, sequential immunofluorescence (seqIF), a multiplexed protein biomarker detection method, allows for simultaneous detection of multiple markers on a single slide by using antibodies with distinct fluorophores combined with the repeated automated cycles of staining, imaging, and elution. While seqIF has quantitative and scalability advantages over IHC, its use of fluorescence introduces various challenges for downstream computational analysis such as tissue’s autofluorescence and non-specific fluorophore accumulation, which are compound by multiple cycles of staining, imaging and elution. The Lunaphore COMET, a seqIF system, allows for an initial background autofluorescence acquisition at the beginning of the protocol. However, we observed that this single baseline measurement did not account changes in the fluorescence of different regions in various tissue types with subsequent imaging and elution cycles, which significantly affected downstream analysis including cell typing.To further investigate these artifacts, we evaluated both autofluorescent quenching on a variety of tissue types during the imaging cycles as well as the non-specific accumulation of fluorophores in all channels (FITC, TRITC, Cy5, and Cy7). We found that the background autofluorescence decreased with sequential cycles in some, but not all cycles, which led to artificially decreased signal intensity for downstream marker analysis. Additionally, we found that non-specific fluorophore accumulation was channel specific, tissue specific, and subcellular localization specific, further confounding interpretability. Overall, these findings suggest that utilizing a single baseline autofluorescence cycle for background subtraction is insufficient and can lead to significant downstream analytical errors.While performing an additional imaging cycle after each elution cycle and subtracting background accordingly may remedy this problem, it is not always feasible or efficient due to increased time, reagent usage, and file size. We found that a total of 5 imaging cycles post-elution accurately predicted the background fluorescence for 20 cycles using a cell-level cubic spline model (R2 = 0.94). These background signal modeling results are then utilized to calculate background-adjusted marker expression values at a cell level for individual cycles, which improved clustering resolution and interoperability. Overall, we demonstrate issues encountered with autofluorescence in seqIF and present a novel method for mitigating them to improve results. Citation Format: Daria I. Mandel, Anton Luis Villamejor, Anthony Colombo, Simeon Mahov, Akil A. Merchant, Joseph Lownik.. Quantitative modeling of autofluorescence and non-specific staining allows for improved cell phenotyping and marker assessment in highly multiplexed immunofluorescence studies [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 2619.

Cancer ResearchVol. 86(7_Supplement)
Cedars-Sinai Medical Center (US)
Openalex Percentile: Top 3%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.