Fire performance of LSF wall panels exposed to fire on both surfaces: a numerical approach

Purpose Load-bearing fire rating is essential for maintaining the structural integrity of light steel frame (LSF) walls during fire events. While most studies examine single-sided fire exposure, two-sided exposure, relevant in some internal wall scenarios, remains underexplored. This study investigates the impact of both side fire exposure on the load-bearing fire rating of LSF walls under various fire conditions. Design/methodology/approach This research employs finite element modelling (FEM) to simulate the structural and thermal response of LSF walls under two-sided fire exposure. The models were calibrated and validated using experimental data from previous studies to ensure accuracy. Parametric studies were conducted to evaluate the effects of plasterboard thickness, number of layers, cavity insulation and load ratios under varying fire scenarios including standard, prolonged, rapid and hydrocarbon fires. Findings The results reveal that two-sided fire exposure significantly reduces the load-bearing fire rating of LSF walls compared to single-sided exposure. Under rapid and hydrocarbon fire conditions, the fire rating was reduced by up to 72%. Conversely, standard and prolonged fires resulted in lower reductions. The degradation in performance varies with construction configuration and exposure type, indicating that certain wall assemblies are more vulnerable under both side fire exposure. Originality/value This study provides the first comprehensive computational investigation into LSF wall performance under two-sided fire conditions. The findings highlight critical gaps in current design practices, emphasizing the need for revised fire safety assessments for internal walls potentially exposed to both side fire scenarios. Designers and engineers can use these insights to improve fire resistance strategies in buildings using LSF systems.

Authors

Institutions

Publication Details

Journal
Journal of Structural Fire Engineering
Published
2026-04-03
DOI
https://doi.org/10.1108/jsfe-07-2025-0035
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fire performance of LSF wall panels exposed to fire on both surfaces: a numerical approach

Heshachanaa Rajanayagam, Mohamed Sifan, Irindu Upasiri, P. Sherlock et al.
Journal of Structural Fire Engineering
Structural Load-Bearing Analysis
article

Fire performance of LSF wall panels exposed to fire on both surfaces: a numerical approach

Heshachanaa Rajanayagam, Mohamed Sifan, Irindu Upasiri, P. Sherlock, Thushanthan Kannan, Anushan Rajadurai, Keerthan Poologanathan, Kaji Kajienthan
article en

Abstract

Purpose Load-bearing fire rating is essential for maintaining the structural integrity of light steel frame (LSF) walls during fire events. While most studies examine single-sided fire exposure, two-sided exposure, relevant in some internal wall scenarios, remains underexplored. This study investigates the impact of both side fire exposure on the load-bearing fire rating of LSF walls under various fire conditions. Design/methodology/approach This research employs finite element modelling (FEM) to simulate the structural and thermal response of LSF walls under two-sided fire exposure. The models were calibrated and validated using experimental data from previous studies to ensure accuracy. Parametric studies were conducted to evaluate the effects of plasterboard thickness, number of layers, cavity insulation and load ratios under varying fire scenarios including standard, prolonged, rapid and hydrocarbon fires. Findings The results reveal that two-sided fire exposure significantly reduces the load-bearing fire rating of LSF walls compared to single-sided exposure. Under rapid and hydrocarbon fire conditions, the fire rating was reduced by up to 72%. Conversely, standard and prolonged fires resulted in lower reductions. The degradation in performance varies with construction configuration and exposure type, indicating that certain wall assemblies are more vulnerable under both side fire exposure. Originality/value This study provides the first comprehensive computational investigation into LSF wall performance under two-sided fire conditions. The findings highlight critical gaps in current design practices, emphasizing the need for revised fire safety assessments for internal walls potentially exposed to both side fire scenarios. Designers and engineers can use these insights to improve fire resistance strategies in buildings using LSF systems.

Journal of Structural Fire Engineering
University of Sri Jayewardenepura (LK), University of the West of England (GB), British Academy (GB), University of Surrey (GB), Northumbria University (GB), Technical Design (United States) (US)
Sustainable cities and communities
Openalex Percentile: Top 24%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.