Impact of sputum quality on Xpert MTB/RIF Ultra test results for tuberculosis: A multi-country study

Rationale: Sputum-based testing using Xpert MTB/RIF Ultra (Xpert) is the most common molecular testing method for diagnosing tuberculosis (TB). Objectives: To evaluate whether sputum quality influences Xpert positivity and diagnostic accuracy. Methods: We screened consecutive people for presumptive TB in India, the Philippines, Vietnam, Nigeria, South Africa, Uganda, and Zambia as part of the R2D2 TB Network and ADAPT studies. Participants provided 2-3 sputum samples for Xpert and culture reference testing. The quality of the first sputum sample was graded following standardized procedures by trained research staff and used for Xpert testing. We performed logistic regression to evaluate whether sputum grade was independently associated with Xpert positivity, and calculated sensitivity and specificity of Xpert against a culture-based microbiological reference standard (MRS). Measurements and Main Results: Among 1,855 participants, 798 (43%) were female, 348 (19%) were living with HIV (PLHIV), and 1795 (97%) had a cough of ≥2 weeks. Overall, 313 (17%) had a positive Xpert result. Most sputum samples were salivary (83%). Xpert positivity was lowest among salivary samples (16.1%) and highest among purulent samples (31.2%). After adjusting for demographic and clinical variables, there was no significant association between any sputum grade and Xpert positivity. Xpert sensitivity (salivary: 89%, mucoid: 91%, mucopurulent: 87%, purulent: 100%) and specificity (>98%) were high across sputum grades. Conclusions: Sputum quality was not independently associated with Xpert positivity and Xpert sensitivity was high across all sputum grades. These findings support molecular testing of all sputum samples for TB diagnosis regardless of macroscopic appearance.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-04-03
DOI
https://doi.org/10.64898/2026.04.01.26350003
Primary Topic
Tuberculosis Research and Epidemiology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of sputum quality on Xpert MTB/RIF Ultra test results for tuberculosis: A multi-country study

Caitlin A. Moe, Monde Muyoyeta, Alfred Andama, P. Nahid et al.
medRxiv
Tuberculosis Research and Epidemiology
article

Impact of sputum quality on Xpert MTB/RIF Ultra test results for tuberculosis: A multi-country study

Caitlin A. Moe, Monde Muyoyeta, Alfred Andama, P. Nahid, John Bimba, William O. Worodria, Kristin Benne Kremer, Grant Theron, DJ Christopher, Van Luong Dinh, A. Cattamanchi, Charles Yu, Shrivaas Vijayan, Seda Yerlikaya, Claudia Denkinger, Sraoshi Barua
article en

Abstract

Rationale: Sputum-based testing using Xpert MTB/RIF Ultra (Xpert) is the most common molecular testing method for diagnosing tuberculosis (TB). Objectives: To evaluate whether sputum quality influences Xpert positivity and diagnostic accuracy. Methods: We screened consecutive people for presumptive TB in India, the Philippines, Vietnam, Nigeria, South Africa, Uganda, and Zambia as part of the R2D2 TB Network and ADAPT studies. Participants provided 2-3 sputum samples for Xpert and culture reference testing. The quality of the first sputum sample was graded following standardized procedures by trained research staff and used for Xpert testing. We performed logistic regression to evaluate whether sputum grade was independently associated with Xpert positivity, and calculated sensitivity and specificity of Xpert against a culture-based microbiological reference standard (MRS). Measurements and Main Results: Among 1,855 participants, 798 (43%) were female, 348 (19%) were living with HIV (PLHIV), and 1795 (97%) had a cough of ≥2 weeks. Overall, 313 (17%) had a positive Xpert result. Most sputum samples were salivary (83%). Xpert positivity was lowest among salivary samples (16.1%) and highest among purulent samples (31.2%). After adjusting for demographic and clinical variables, there was no significant association between any sputum grade and Xpert positivity. Xpert sensitivity (salivary: 89%, mucoid: 91%, mucopurulent: 87%, purulent: 100%) and specificity (>98%) were high across sputum grades. Conclusions: Sputum quality was not independently associated with Xpert positivity and Xpert sensitivity was high across all sputum grades. These findings support molecular testing of all sputum samples for TB diagnosis regardless of macroscopic appearance.

medRxiv
South African Medical Research Council (ZA), Centre for Infectious Disease Research in Zambia (ZM), Christian Medical College, Vellore (IN), University of California, San Francisco (US), Bingham University (NG), University of California, Irvine (US), Heidelberg University (DE), Stellenbosch University (ZA), TuBerculosis Vaccine Initiative (NL), University Hospital Heidelberg (DE), Center for Promotion of Advancement of Society (VN), German Center for Infection Research (DE), Hanoi Lung Hospital (VN), Makerere University (UG), University of California, Davis (US)
National Institutes of Health, National Institute of Allergy and Infectious Diseases
Good health and well-being
Openalex Percentile: Top 26%
Tuberculosis Research and Epidemiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.