Comparative study of UV analytical method and anova application in evaluating Dapagliflozin propanediol monohydrate and teneligliptin hydrobromide hydrate

Abstract Background Dapagliflozin, an inhibitor of sodium-glucose co-transporter 2 (SGLT2), and teneligliptin, an inhibitor of dipeptidyl peptidase-4 (DPP-4), are two important oral anti-diabetic medications that are commonly used to treat type 2 diabetes mellitus. By providing different modes of action, these drugs enhance glucose regulation and reduce the chance of long-term complications associated with diabetes. This research seeks to develop and validate a dependable UV spectrophotometric method for analyzing dapagliflozin and teneligliptin, ensuring it conforms to ICH regulations with high accuracy and precision. The developed UV method was compared with existing UV approaches using a one-way ANOVA test. Results Method A : The absorption correction spectrophotometric technique is incorporated into the amplitude of the spectra at 224.60 nm for DAPA and 246.60 nm for TENE. In the process, methanol of HPLC purity was used as solvent. Beer's rule applied to DAPA and TENE at concentrations between 4–12 and 8–24 μg/mL, respectively. Method B : The novel spectrophotometric technique of ratio spectra derivative is used to measure the absorbance for DAPA and TENE at 219.60 nm and 254.20 nm, respectively, using HPLC-grade methanol as the solvent. Method C : The first-order derivative spectrophotometric method was created using distilled water as the solvent. Spectral amplitudes were measured at 266 nm for TENE and 231.60 nm for DAPA. The process demonstrated compliance with Beer's law, with concentration ranges of 4–12 μg/mL for DAPA and 8–24 μg/mL for TENE. The developed method is compared to the previously reported method and the analysis produced a p-value of 1 for the UV technique, which is higher than the significance level of 0.05. The null hypothesis is accepted since there is no statistically significant difference between the approaches. The distinct polarity requirements of DAPA and TENE are reflected in the use of distilled water in Method C and HPLC-grade methanol in Methods A and B. Water slightly shifts λmax and increases baseline noise, which was assessed during robustness studies, while methanol enhances solubility and spectral clarity. Conclusion The UV spectrophotometric approach created for dapagliflozin and teneligliptin has shown itself to be accurate, dependable and cost-effective; it meets all ICH standards for analytical technique validation. This technology provides a dependable approach for routine quality monitoring by making it simpler to quantify these drugs concurrently in pharmaceutical compositions. The one-way ANOVA test conducted demonstrated significant finding.

Authors

Publication Details

Journal
Future Journal of Pharmaceutical Sciences
Published
2026-04-03
DOI
https://doi.org/10.1186/s43094-026-00970-3
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative study of UV analytical method and anova application in evaluating Dapagliflozin propanediol monohydrate and teneligliptin hydrobromide hydrate

Sheeja Velayudhan Kutty, D Santhosh, Swapna A. Surendran, Y. Haribabu et al.
Future Journal of Pharmaceutical Sciences
Analytical Methods in Pharmaceuticals
article

Comparative study of UV analytical method and anova application in evaluating Dapagliflozin propanediol monohydrate and teneligliptin hydrobromide hydrate

Sheeja Velayudhan Kutty, D Santhosh, Swapna A. Surendran, Y. Haribabu, Ajumal Hassanar, Amala Ashokan, Anjali Aravind, Muhamed Absher
article en

Abstract

Abstract Background Dapagliflozin, an inhibitor of sodium-glucose co-transporter 2 (SGLT2), and teneligliptin, an inhibitor of dipeptidyl peptidase-4 (DPP-4), are two important oral anti-diabetic medications that are commonly used to treat type 2 diabetes mellitus. By providing different modes of action, these drugs enhance glucose regulation and reduce the chance of long-term complications associated with diabetes. This research seeks to develop and validate a dependable UV spectrophotometric method for analyzing dapagliflozin and teneligliptin, ensuring it conforms to ICH regulations with high accuracy and precision. The developed UV method was compared with existing UV approaches using a one-way ANOVA test. Results Method A : The absorption correction spectrophotometric technique is incorporated into the amplitude of the spectra at 224.60 nm for DAPA and 246.60 nm for TENE. In the process, methanol of HPLC purity was used as solvent. Beer's rule applied to DAPA and TENE at concentrations between 4–12 and 8–24 μg/mL, respectively. Method B : The novel spectrophotometric technique of ratio spectra derivative is used to measure the absorbance for DAPA and TENE at 219.60 nm and 254.20 nm, respectively, using HPLC-grade methanol as the solvent. Method C : The first-order derivative spectrophotometric method was created using distilled water as the solvent. Spectral amplitudes were measured at 266 nm for TENE and 231.60 nm for DAPA. The process demonstrated compliance with Beer's law, with concentration ranges of 4–12 μg/mL for DAPA and 8–24 μg/mL for TENE. The developed method is compared to the previously reported method and the analysis produced a p-value of 1 for the UV technique, which is higher than the significance level of 0.05. The null hypothesis is accepted since there is no statistically significant difference between the approaches. The distinct polarity requirements of DAPA and TENE are reflected in the use of distilled water in Method C and HPLC-grade methanol in Methods A and B. Water slightly shifts λmax and increases baseline noise, which was assessed during robustness studies, while methanol enhances solubility and spectral clarity. Conclusion The UV spectrophotometric approach created for dapagliflozin and teneligliptin has shown itself to be accurate, dependable and cost-effective; it meets all ICH standards for analytical technique validation. This technology provides a dependable approach for routine quality monitoring by making it simpler to quantify these drugs concurrently in pharmaceutical compositions. The one-way ANOVA test conducted demonstrated significant finding.

Future Journal of Pharmaceutical SciencesVol. 12(1)
Good health and well-being
Openalex Percentile: Top 34%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.