Abstract 6683: Streamlined high-plex imaging with InSituPlex®and ZEISS Axioscan 7 for spatial phenotyping

Abstract Multiplex immunofluorescence (mIF) provides a powerful means to visualize complex biomarker signatures with spatial context. Yet, most high-plex mIF approaches depend on repeated cycles of staining and imaging, which introduce workflow complexity and necessitate either labor-intensive manual handling or sophisticated instrumentation capable of automating these multistep procedures. Vizgen’s InSituPlex assay supports rapid, multiplexed detection of up to 12 protein biomarkers in a single staining step, leveraging signal amplification to achieve robust detection of both abundant and lowly expressed targets using standard fluorescence filter configurations. When combined with the Axioscan 7 spatial biology platform, engineered for fully automated, high-throughput slide scanning with additional fluorescent channels, this workflow enables higher-plex, single-round imaging without the need for spectral unmixing. Here, we demonstrate the power of this integrated approach to streamline assay development, expand biomarker panel design flexibility, and deliver efficient, scalable multiplexed protein imaging. A next generation InSituPlex® assay was developed to increase the simultaneous detection of markers using the Axioscan 7 spatial biology system. A panel of fluorophores was carefully selected to minimize spectral overlap and maximize detection specificity, ensuring clear distinction of all fluorescent channels without requiring spectral unmixing to deconvolute signals. Signal quality was analyzed using the STARVUE image analysis pipeline which precisely determined positive cell signal intensity and density. The increased number of fluorophores showed excellent signal to noise ratio and no crosstalk between fluorescent channels. The expanded channel capacity of InSituPlex assay allows for a simplified workflow while increasing the number of biomarkers that can simultaneously be detected in tumor samples. This capability further enhances flexibility for InSituPlex panel design and streamlines the assay development process. The integration of the novel InSituPlex fluorescent dye panel and the Axioscan 7 spatial biology platform delivers a superior, high throughput mIF workflow. This combination enables higher-plex imaging while significantly reducing manual steps, leveraging the established reproducibility and throughput of both technologies. We anticipate this integrated platform will empower researchers to unlock deeper, high resolution spatial insights into cancers and their complex environments. Citation Format: Kevin Hwang, Mike Woerdemann, Lars Loetgering, Moritz Widmaier, Cassandra Kysilovsky, Sherry Derakhshani, Jiang He, Angela Vasaturo. Streamlined high-plex imaging with InSituPlex®and ZEISS Axioscan 7 for spatial phenotyping [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 6683.

Authors

Institutions

Publication Details

Journal
Cancer Research
Published
2026-04-03
DOI
https://doi.org/10.1158/1538-7445.am2026-6683
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 6683: Streamlined high-plex imaging with InSituPlex®and ZEISS Axioscan 7 for spatial phenotyping

Lars Loetgering, Moritz Widmaier, Mike Woerdemann, Cassandra Kysilovsky et al.
Cancer Research
Advanced Fluorescence Microscopy Techniques
article

Abstract 6683: Streamlined high-plex imaging with InSituPlex®and ZEISS Axioscan 7 for spatial phenotyping

Lars Loetgering, Moritz Widmaier, Mike Woerdemann, Cassandra Kysilovsky, Angela Vasaturo, Kevin Hwang, Sherry Derakhshani, Jiang He
article en

Abstract

Abstract Multiplex immunofluorescence (mIF) provides a powerful means to visualize complex biomarker signatures with spatial context. Yet, most high-plex mIF approaches depend on repeated cycles of staining and imaging, which introduce workflow complexity and necessitate either labor-intensive manual handling or sophisticated instrumentation capable of automating these multistep procedures. Vizgen’s InSituPlex assay supports rapid, multiplexed detection of up to 12 protein biomarkers in a single staining step, leveraging signal amplification to achieve robust detection of both abundant and lowly expressed targets using standard fluorescence filter configurations. When combined with the Axioscan 7 spatial biology platform, engineered for fully automated, high-throughput slide scanning with additional fluorescent channels, this workflow enables higher-plex, single-round imaging without the need for spectral unmixing. Here, we demonstrate the power of this integrated approach to streamline assay development, expand biomarker panel design flexibility, and deliver efficient, scalable multiplexed protein imaging. A next generation InSituPlex® assay was developed to increase the simultaneous detection of markers using the Axioscan 7 spatial biology system. A panel of fluorophores was carefully selected to minimize spectral overlap and maximize detection specificity, ensuring clear distinction of all fluorescent channels without requiring spectral unmixing to deconvolute signals. Signal quality was analyzed using the STARVUE image analysis pipeline which precisely determined positive cell signal intensity and density. The increased number of fluorophores showed excellent signal to noise ratio and no crosstalk between fluorescent channels. The expanded channel capacity of InSituPlex assay allows for a simplified workflow while increasing the number of biomarkers that can simultaneously be detected in tumor samples. This capability further enhances flexibility for InSituPlex panel design and streamlines the assay development process. The integration of the novel InSituPlex fluorescent dye panel and the Axioscan 7 spatial biology platform delivers a superior, high throughput mIF workflow. This combination enables higher-plex imaging while significantly reducing manual steps, leveraging the established reproducibility and throughput of both technologies. We anticipate this integrated platform will empower researchers to unlock deeper, high resolution spatial insights into cancers and their complex environments. Citation Format: Kevin Hwang, Mike Woerdemann, Lars Loetgering, Moritz Widmaier, Cassandra Kysilovsky, Sherry Derakhshani, Jiang He, Angela Vasaturo. Streamlined high-plex imaging with InSituPlex®and ZEISS Axioscan 7 for spatial phenotyping [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 6683.

Cancer ResearchVol. 86(7_Supplement)
Carl Zeiss (Germany) (DE)
Decent work and economic growth
Openalex Percentile: Top 27%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.