The test-retest reliability and agreement between a fixed frame and belt-stabilised handheld dynamometer for isometric hip flexion and extension peak force measurement in recreational cyclists

INTRODUCTION: Cycling performance is influenced by hip flexor and extensor muscle strength. While belt stabilised handheld dynamometers (B-HHD) are valid for measuring isometric hip muscle strength, fixed frame dynamometers are becoming popular, offering potentially better stability and reliability. However, the reliability of both devices has not been examined in cyclists. This study evaluated the test-retest reliability and agreement between a B-HHD (MicroFET2, Hoggan Scientific) and a fixed-frame dynamometer (ForceFrame (FF) Max, Vald Performance) for hip flexion and extension peak force measurement in cyclists. METHODS: A test-retest design was used. Twenty-five recreational cyclists (age ± SD: 36.64 (±12.34) years; 22 males) were tested twice, approximately 72 hours apart. Three unilateral maximal voluntary isometric contractions (MVIC) of the hip flexors and extensors of each limb were performed, using the B-HHD and FF in a random order. Within and between session reliability was determined using intraclass correlation coefficients (ICCs) 3.1 & 3.k. Standard error of measurements (SEM) and minimal detectable changes (MDC) were calculated. Agreement was assessed using 95% limits of agreement (LOA). RESULTS: For hip flexion, within and between session reliability was good to excellent, and SEMs were similar (B-HHD ICCs = 0.77-0.93, SEMs = 14.25-22.71N (7.19-10.38%); FF ICCs = 0.77-0.95, SEMs = 7.80N-18.98N (3.47%-8.54%)). FF MDCs were lower within-session (21.61-39.48N (9.60-17.97%)) than B-HHD MDCs (39.50-62.95N (19.94-28.78%)), but similar between-sessions (FF MDCs = 41.25-52.61N (19.42-23.66%); B-HHD MDCs = 41.21N-48.95N (18.53-23.77%)). For hip extension, both devices demonstrated good to excellent reliability and SEMs were similar (B-HHD ICCs = 0.90-0.95, SEMs = 15.77-21.53N (7.38-9.96%); FF ICCs = 0.85-0.95, SEMs = 19.21-29.05N (7.82-11.78%) within and between sessions). All LOA exceeded a 20N acceptability threshold. CONCLUSION: Both devices are reliable in recreational cyclists, but large MDCs suggest that caution is needed when interpreting repeated measurements. Due to poor agreement, the devices are not interchangeable so should be considered device specific. In practice, our preliminary results suggest FF data cannot be compared with B-HHD data and vice versa, so the same device should be used for repeated measurements in this population.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-04-03
DOI
https://doi.org/10.1371/journal.pone.0328143
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The test-retest reliability and agreement between a fixed frame and belt-stabilised handheld dynamometer for isometric hip flexion and extension peak force measurement in recreational cyclists

Benn Digweed, Dion D’Mello, Tom Hughes
PLoS ONE
Sports Performance and Training
article

The test-retest reliability and agreement between a fixed frame and belt-stabilised handheld dynamometer for isometric hip flexion and extension peak force measurement in recreational cyclists

Benn Digweed, Dion D’Mello, Tom Hughes
article en

Abstract

INTRODUCTION: Cycling performance is influenced by hip flexor and extensor muscle strength. While belt stabilised handheld dynamometers (B-HHD) are valid for measuring isometric hip muscle strength, fixed frame dynamometers are becoming popular, offering potentially better stability and reliability. However, the reliability of both devices has not been examined in cyclists. This study evaluated the test-retest reliability and agreement between a B-HHD (MicroFET2, Hoggan Scientific) and a fixed-frame dynamometer (ForceFrame (FF) Max, Vald Performance) for hip flexion and extension peak force measurement in cyclists. METHODS: A test-retest design was used. Twenty-five recreational cyclists (age ± SD: 36.64 (±12.34) years; 22 males) were tested twice, approximately 72 hours apart. Three unilateral maximal voluntary isometric contractions (MVIC) of the hip flexors and extensors of each limb were performed, using the B-HHD and FF in a random order. Within and between session reliability was determined using intraclass correlation coefficients (ICCs) 3.1 & 3.k. Standard error of measurements (SEM) and minimal detectable changes (MDC) were calculated. Agreement was assessed using 95% limits of agreement (LOA). RESULTS: For hip flexion, within and between session reliability was good to excellent, and SEMs were similar (B-HHD ICCs = 0.77-0.93, SEMs = 14.25-22.71N (7.19-10.38%); FF ICCs = 0.77-0.95, SEMs = 7.80N-18.98N (3.47%-8.54%)). FF MDCs were lower within-session (21.61-39.48N (9.60-17.97%)) than B-HHD MDCs (39.50-62.95N (19.94-28.78%)), but similar between-sessions (FF MDCs = 41.25-52.61N (19.42-23.66%); B-HHD MDCs = 41.21N-48.95N (18.53-23.77%)). For hip extension, both devices demonstrated good to excellent reliability and SEMs were similar (B-HHD ICCs = 0.90-0.95, SEMs = 15.77-21.53N (7.38-9.96%); FF ICCs = 0.85-0.95, SEMs = 19.21-29.05N (7.82-11.78%) within and between sessions). All LOA exceeded a 20N acceptability threshold. CONCLUSION: Both devices are reliable in recreational cyclists, but large MDCs suggest that caution is needed when interpreting repeated measurements. Due to poor agreement, the devices are not interchangeable so should be considered device specific. In practice, our preliminary results suggest FF data cannot be compared with B-HHD data and vice versa, so the same device should be used for repeated measurements in this population.

PLoS ONEVol. 21(4)
Manchester Metropolitan University (GB), English Institute of Sport (GB)
Openalex Percentile: Top 31%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.