Evaluation of Ultrasound Shear Wave Elastography ( <scp>SWE</scp> ) and Attenuation Imaging ( <scp>ATI</scp> ) for the Assessment of Hepatic Fibrosis and Steatosis—A Prospective Comparison With <scp>MRI</scp> Liver Elastography and Proton Density Fat

INTRODUCTION: To assess competing US techniques in evaluation of chronic liver disease, we performed a study to determine the diagnostic accuracy of 2D-shear wave elastography (2D-SWE) and attenuation imaging (ATI) compared with more established methods of point shear wave elastography (pSWE) and visual B-mode grading of hepatic steatosis. Magnetic resonance elastography (MRE) and proton density fat fraction (MR-PDFF) were used as respective reference standards. METHODS: Fifty-five patients underwent same-day liver ultrasound (conventional B-mode, pSWE, 2D-SWE, and ATI) and 3 T MRI (MRE and MR-PDFF). Diagnostic performance for steatosis (mild, moderate, severe) and fibrosis (≥ F2, ≥ F3, and F4) grades was assessed using receiver operating characteristic (ROC) curve analysis, with area under the curve (AUC) calculated. Agreement was evaluated using Cohen's kappa for categorical comparisons and intraclass correlation coefficients (ICC) for continuous measurements within the same modality. RESULTS: For fibrosis, 2D-SWE demonstrated high sensitivity (100%) for advanced fibrosis (≥ F3; AUC 0.87), compared with pSWE (sensitivity of 71.4%). In contrast, pSWE showed higher specificity (92.3%) for significant fibrosis (≥ F2) compared to 2D-SWE (73.9%). Categorical agreement with MRE was higher for pSWE (kappa = 0.66) than 2D-SWE (kappa = 0.45). For steatosis, visual B-mode across all grades had AUC 0.85-0.89 compared to 0.68-0.85 for ATI. ATI performed best in detecting severe steatosis (AUC 0.85). CONCLUSION: Across the spectrum of clinically relevant assessment of liver fibrosis and steatosis, pSWE and visual B-mode grading showed better correlation with MRI results than 2D-SWE and ATI, respectively. However, they did provide good diagnostic performance in grading liver fibrosis and steatosis in advanced disease. Further research may better define more accurate standardised cut-off scores for the 2D-SWE and ATI techniques.

Authors

Institutions

Publication Details

Journal
Journal of Medical Imaging and Radiation Oncology
Published
2026-04-03
DOI
https://doi.org/10.1111/1754-9485.70093
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Ultrasound Shear Wave Elastography ( SWE ) and Attenuation Imaging ( ATI ) for the Assessment of Hepatic Fibrosis and Steatosis—A Prospective Comparison With MRI Liver Elastography and Proton Density Fat

Paul Simkin, Joel Hng, Jeffrey Lai, Wayland Wang et al.
Journal of Medical Imaging and Radiation Oncology
Liver Disease Diagnosis and Treatment
article

Evaluation of Ultrasound Shear Wave Elastography ( SWE ) and Attenuation Imaging ( ATI ) for the Assessment of Hepatic Fibrosis and Steatosis—A Prospective Comparison With MRI Liver Elastography and Proton Density Fat

Paul Simkin, Joel Hng, Jeffrey Lai, Wayland Wang, Damien Stella, Beng Ghee Lim, Jessica Y. Lee, Siddharth Sood, Robert N. Gibson
article en

Abstract

INTRODUCTION: To assess competing US techniques in evaluation of chronic liver disease, we performed a study to determine the diagnostic accuracy of 2D-shear wave elastography (2D-SWE) and attenuation imaging (ATI) compared with more established methods of point shear wave elastography (pSWE) and visual B-mode grading of hepatic steatosis. Magnetic resonance elastography (MRE) and proton density fat fraction (MR-PDFF) were used as respective reference standards. METHODS: Fifty-five patients underwent same-day liver ultrasound (conventional B-mode, pSWE, 2D-SWE, and ATI) and 3 T MRI (MRE and MR-PDFF). Diagnostic performance for steatosis (mild, moderate, severe) and fibrosis (≥ F2, ≥ F3, and F4) grades was assessed using receiver operating characteristic (ROC) curve analysis, with area under the curve (AUC) calculated. Agreement was evaluated using Cohen's kappa for categorical comparisons and intraclass correlation coefficients (ICC) for continuous measurements within the same modality. RESULTS: For fibrosis, 2D-SWE demonstrated high sensitivity (100%) for advanced fibrosis (≥ F3; AUC 0.87), compared with pSWE (sensitivity of 71.4%). In contrast, pSWE showed higher specificity (92.3%) for significant fibrosis (≥ F2) compared to 2D-SWE (73.9%). Categorical agreement with MRE was higher for pSWE (kappa = 0.66) than 2D-SWE (kappa = 0.45). For steatosis, visual B-mode across all grades had AUC 0.85-0.89 compared to 0.68-0.85 for ATI. ATI performed best in detecting severe steatosis (AUC 0.85). CONCLUSION: Across the spectrum of clinically relevant assessment of liver fibrosis and steatosis, pSWE and visual B-mode grading showed better correlation with MRI results than 2D-SWE and ATI, respectively. However, they did provide good diagnostic performance in grading liver fibrosis and steatosis in advanced disease. Further research may better define more accurate standardised cut-off scores for the 2D-SWE and ATI techniques.

Journal of Medical Imaging and Radiation Oncology
The Royal Melbourne Hospital (AU), The University of Melbourne (AU), Northern Hospital (AU), Western Health (AU), Melbourne Clinic (AU)
Canon Medical Systems Corporation, Australasian Society for Ultrasound in Medicine
Openalex Percentile: Top 24%
Liver Disease Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.