Hemodynamic Evaluation of the WeFlow-Tribranch Modular Triple-Branched Endograft System for Aortic Arch Pathologies: An Initial Computational Fluid Dynamics Study

PURPOSE: To evaluate the hemodynamic performance and clinical implications of the WeFlow-Tribranch modular endograft system using patient-specific computational fluid dynamics (CFD) analysis. METHODS: Pre- and postoperative CTA data sets from 3 patients treated with the WeFlow-Tribranch system were used to reconstruct 3-dimensional aortic models. CFD simulations were performed to compare changes in blood flow patterns, branch perfusion, and wall shear stress (WSS) parameters. The analysis focused on clinical metrics including branch perfusion distribution and hemodynamic markers associated with thrombus risk (TAWSS: time-averaged wall shear stress, OSI: oscillatory shear index, and RRT: relative residence time). RESULTS: In the 3 analyzed cases, postoperative simulations showed that the device successfully restored more organized flow patterns in the aortic arch and effectively excluded aneurysms. Perfusion to the left common carotid artery (LCCA) improved in all 3 cases (+13% to +56%). However, perfusion to the brachiocephalic trunk (BCT) and left subclavian artery (LSA) varied substantially among the cases. Furthermore, simulations identified localized regions of low TAWSS and high OSI within the reconstructed branch tunnels, indicating potential sites for flow stagnation despite improvements in the main aortic flow. CONCLUSION: system offers a modular, minimally invasive solution for complex aortic arch pathologies. This CFD study demonstrates that while the device restores organized aortic flow and improves LCCA perfusion, its embedded branch design introduces localized flow disturbances and patient-specific variations in BCT and LSA perfusion. For clinicians, these findings emphasize that anatomical feasibility alone is insufficient for patient selection. Meticulous pre-operative planning and rigorous post-operative surveillance of branch patency are essential to mitigate risks of thrombosis or ischemia induced by non-physiological wall shear stress.

Authors

Institutions

Publication Details

Journal
Journal of Endovascular Therapy
Published
2026-04-03
DOI
https://doi.org/10.1177/15266028261417152
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hemodynamic Evaluation of the WeFlow-Tribranch Modular Triple-Branched Endograft System for Aortic Arch Pathologies: An Initial Computational Fluid Dynamics Study

Haiping Tian, Hui Song, Hongpeng Zhang, Zhuoxin Deng et al.
Journal of Endovascular Therapy
Aortic Disease and Treatment Approaches
article

Hemodynamic Evaluation of the WeFlow-Tribranch Modular Triple-Branched Endograft System for Aortic Arch Pathologies: An Initial Computational Fluid Dynamics Study

Haiping Tian, Hui Song, Hongpeng Zhang, Zhuoxin Deng, Wei Guo
article en

Abstract

PURPOSE: To evaluate the hemodynamic performance and clinical implications of the WeFlow-Tribranch modular endograft system using patient-specific computational fluid dynamics (CFD) analysis. METHODS: Pre- and postoperative CTA data sets from 3 patients treated with the WeFlow-Tribranch system were used to reconstruct 3-dimensional aortic models. CFD simulations were performed to compare changes in blood flow patterns, branch perfusion, and wall shear stress (WSS) parameters. The analysis focused on clinical metrics including branch perfusion distribution and hemodynamic markers associated with thrombus risk (TAWSS: time-averaged wall shear stress, OSI: oscillatory shear index, and RRT: relative residence time). RESULTS: In the 3 analyzed cases, postoperative simulations showed that the device successfully restored more organized flow patterns in the aortic arch and effectively excluded aneurysms. Perfusion to the left common carotid artery (LCCA) improved in all 3 cases (+13% to +56%). However, perfusion to the brachiocephalic trunk (BCT) and left subclavian artery (LSA) varied substantially among the cases. Furthermore, simulations identified localized regions of low TAWSS and high OSI within the reconstructed branch tunnels, indicating potential sites for flow stagnation despite improvements in the main aortic flow. CONCLUSION: system offers a modular, minimally invasive solution for complex aortic arch pathologies. This CFD study demonstrates that while the device restores organized aortic flow and improves LCCA perfusion, its embedded branch design introduces localized flow disturbances and patient-specific variations in BCT and LSA perfusion. For clinicians, these findings emphasize that anatomical feasibility alone is insufficient for patient selection. Meticulous pre-operative planning and rigorous post-operative surveillance of branch patency are essential to mitigate risks of thrombosis or ischemia induced by non-physiological wall shear stress.

Journal of Endovascular Therapy
Chinese PLA General Hospital (CN), Taiyuan University of Technology (CN)
Openalex Percentile: Top 25%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.