Abstract 6336: AmbientcfRNApreservation: standardized extraction reveals superior stability in a multi-analyte tube

Abstract Introduction: Liquid-biopsy readouts are highly sensitive to pre-analytical variability: cellular lysis and nuclease activity can inflate background, suppress rare signals, and impair reproducibility. Concurrent stabilization of multiple targets at the time of collection, paired with a controlled extraction workflow, is therefore critical. We assessed two blood-collection tubes—a single-tube matrix designed for multi-analyte stability—using the magnetic bead-based chemistry, focusing on cfRNA signal integrity and compatibility with downstream RT-qPCR. Methods: Whole blood from healthy donors was drawn into Tube-A (TAG FLEX-LB™) and Tube-B (Streck Nucleic Acid BCT) aliquots were spiked with purified total RNA from H441 cells (KRAS G12V) at a fixed concentration per mL. Tubes were stored at ∼21-25 °C and processed at T0 and T7. cfRNA was isolated using silica-magnetic bead Revolution cfTNA Max 20 Kit. Endpoints: allele-specific RT-qPCR for KRAS G12V (Ct; ΔCt = T7-T0; amplification efficiency and recovery), hemolysis proxy hsa-miR-16 (ΔCt), and RNA integrity (RIN; 18S/28S). Statistics: paired tests with 95% Confidence Intervals. Results: With one extraction workflow across both tubes, KRAS G12V amplified consistently at T0. After 7 days at room temperature, Tube-A showed minimal degradation, preserved efficiency, and maintained high recovery. Tube-B exhibited greater degradation and reduced efficiency in recovery. Hemolysis signal was lower in Tube-A: Day-7 miR-16 abundance was lower than Tube-B. RNA integrity remained stable in Tube-A but declined in Tube-B. Assay QC pass rate were higher for Tube-A. Conclusions: Under a realistic 7-day ambient hold, cfRNA targets remained quantifiable when stabilization was adequate. In this head-to-head study, the multi-analyte stabilizing tube better preserved KRAS-G12V detectability, showed lower hemolysis, and maintained RIN/18S-28S metrics relative to a different tube, using an identical extraction workflow. These findings support cfRNA workflows and underscore the need for standardized pre-analytics—spanning both preservation and extraction. Citation Format: Emily Medina, Tony Baker, Kamran Syed, Jason Saenz, Cameron Van Dieren, Carlos Hernandez, Daniel Cedeno, Mayer Saidian, Nafiseh Jafari. AmbientcfRNApreservation: standardized extraction reveals superior stability in a multi-analyte tube [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 6336.

Authors

Institutions

Publication Details

Journal
Cancer Research
Published
2026-04-03
DOI
https://doi.org/10.1158/1538-7445.am2026-6336
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 6336: AmbientcfRNApreservation: standardized extraction reveals superior stability in a multi-analyte tube

Nafiseh Jafari, Carlos Hernández, Mayer Saidian, Tony Baker et al.
Cancer Research
Biosensors and Analytical Detection
article

Abstract 6336: AmbientcfRNApreservation: standardized extraction reveals superior stability in a multi-analyte tube

Nafiseh Jafari, Carlos Hernández, Mayer Saidian, Tony Baker, Jason Saenz, Cameron Van Dieren, Daniel Cedeno, Kamran Syed, Emily Medina
article en

Abstract

Abstract Introduction: Liquid-biopsy readouts are highly sensitive to pre-analytical variability: cellular lysis and nuclease activity can inflate background, suppress rare signals, and impair reproducibility. Concurrent stabilization of multiple targets at the time of collection, paired with a controlled extraction workflow, is therefore critical. We assessed two blood-collection tubes—a single-tube matrix designed for multi-analyte stability—using the magnetic bead-based chemistry, focusing on cfRNA signal integrity and compatibility with downstream RT-qPCR. Methods: Whole blood from healthy donors was drawn into Tube-A (TAG FLEX-LB™) and Tube-B (Streck Nucleic Acid BCT) aliquots were spiked with purified total RNA from H441 cells (KRAS G12V) at a fixed concentration per mL. Tubes were stored at ∼21-25 °C and processed at T0 and T7. cfRNA was isolated using silica-magnetic bead Revolution cfTNA Max 20 Kit. Endpoints: allele-specific RT-qPCR for KRAS G12V (Ct; ΔCt = T7-T0; amplification efficiency and recovery), hemolysis proxy hsa-miR-16 (ΔCt), and RNA integrity (RIN; 18S/28S). Statistics: paired tests with 95% Confidence Intervals. Results: With one extraction workflow across both tubes, KRAS G12V amplified consistently at T0. After 7 days at room temperature, Tube-A showed minimal degradation, preserved efficiency, and maintained high recovery. Tube-B exhibited greater degradation and reduced efficiency in recovery. Hemolysis signal was lower in Tube-A: Day-7 miR-16 abundance was lower than Tube-B. RNA integrity remained stable in Tube-A but declined in Tube-B. Assay QC pass rate were higher for Tube-A. Conclusions: Under a realistic 7-day ambient hold, cfRNA targets remained quantifiable when stabilization was adequate. In this head-to-head study, the multi-analyte stabilizing tube better preserved KRAS-G12V detectability, showed lower hemolysis, and maintained RIN/18S-28S metrics relative to a different tube, using an identical extraction workflow. These findings support cfRNA workflows and underscore the need for standardized pre-analytics—spanning both preservation and extraction. Citation Format: Emily Medina, Tony Baker, Kamran Syed, Jason Saenz, Cameron Van Dieren, Carlos Hernandez, Daniel Cedeno, Mayer Saidian, Nafiseh Jafari. AmbientcfRNApreservation: standardized extraction reveals superior stability in a multi-analyte tube [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 6336.

Cancer ResearchVol. 86(7_Supplement)
ID Genomics (United States) (US), Western Digital (United States) (US)
Openalex Percentile: Top 7%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.