Analysis of seismic performance in semi-dry joint assembled prefabricated shear wall

Premanufactured and site-assembled buildings are widely used in engineering due to their high construction efficiency. However, there are still technical problems such as joint stress concentration and insufficient seismic performance in node connections. To solve the problem of joint connection in assembled shear walls, four new semi-dry connection methods are proposed. Through comparing and analysing their mechanical properties, the connection method with the best comprehensive performance is selected, providing a theoretical basis for engineering applications. Based on Abaqus finite-element software, four types of semi-dry connected assembled shear wall models are established under unified parameter conditions and compared and analysed with simulated cast-in-place composite shear walls. The results show that the specimens using the D-D connection method have optimal seismic performance, with ultimate bearing capacity comparable to cast-in-place specimens and good residual deformation capacity. As the aspect ratio increases, the displacement ductility coefficient of the specimen decreases. When the axial compression ratio exceeds a certain threshold, the degradation rate of structural stiffness significantly accelerates.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Civil Engineers - Structures and Buildings
Published
2026-04-03
DOI
https://doi.org/10.1680/jstbu.25.00238
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of seismic performance in semi-dry joint assembled prefabricated shear wall

Mohan Zhou, Guozhou Yang, Y. F. Wang, Yansong Li
Proceedings of the Institution of Civil Engineers - Structures and Buildings
Seismic Performance and Analysis
article

Analysis of seismic performance in semi-dry joint assembled prefabricated shear wall

Mohan Zhou, Guozhou Yang, Y. F. Wang, Yansong Li
article en

Abstract

Premanufactured and site-assembled buildings are widely used in engineering due to their high construction efficiency. However, there are still technical problems such as joint stress concentration and insufficient seismic performance in node connections. To solve the problem of joint connection in assembled shear walls, four new semi-dry connection methods are proposed. Through comparing and analysing their mechanical properties, the connection method with the best comprehensive performance is selected, providing a theoretical basis for engineering applications. Based on Abaqus finite-element software, four types of semi-dry connected assembled shear wall models are established under unified parameter conditions and compared and analysed with simulated cast-in-place composite shear walls. The results show that the specimens using the D-D connection method have optimal seismic performance, with ultimate bearing capacity comparable to cast-in-place specimens and good residual deformation capacity. As the aspect ratio increases, the displacement ductility coefficient of the specimen decreases. When the axial compression ratio exceeds a certain threshold, the degradation rate of structural stiffness significantly accelerates.

Proceedings of the Institution of Civil Engineers - Structures and Buildings
China Three Gorges University (CN), Henan University of Urban Construction (CN)
Sustainable cities and communities
Openalex Percentile: Top 6%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.