A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy

BACKGROUND: Conventional volumetric modulated arc therapy (VMAT) is limited by its longitudinal field size for large targets, often requiring multiple isocenters, while Helical Tomotherapy (HT) offers superior longitudinal conformity but suffers from prolonged treatment times due to its narrow fan beam. PURPOSE: This simulation study proposes a novel spiral volumetric modulated arc therapy (SVMAT) technique designed to bridge this gap by synergizing continuous couch movement with dynamic MLC modulation. METHODS: The SVMAT technique was implemented on a model of ring-gantry linac with dual-layer staggered MLC. Its core is a direct aperture optimization algorithm that discretizes the delivery path into finite projections, concurrently optimizing MLC aperture, monitor unit weight, gantry angle, and couch position. A comprehensive dosimetric and efficiency comparison was conducted against state-of-the-art VMAT and HT plans for three clinically challenging scenarios: hippocampal-sparing whole-brain radiotherapy (HS-WBRT), bilateral breast radiotherapy (BBRT), and craniospinal irradiation (CSI), including a pediatric subgroup. RESULTS: by 36.1%. Also, the pediatric CSI analysis confirmed these benefits, with SVMAT significantly reducing doses to developing organs. Regarding efficiency, SVMAT's beam on time was significantly shorter than HT's across all plans (reductions of 33.1% to 55.3%) and was comparable to the multi-isocenter VMAT in CSI. CONCLUSIONS: The SVMAT technique successfully integrates the dynamic delivery of VMAT with the longitudinal integration and single-isocenter capability of HT. By offering enhanced OAR sparing and reduced treatment times, SVMAT represents a significant advancement in radiotherapy, showing immense potential for improving outcomes, especially in vulnerable populations such as pediatric patients.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-04-01
DOI
https://doi.org/10.1002/mp.70423
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy

Xingmin Ma, Qichao Zhou, Wei Zhang, Jian Zhu et al.
Medical Physics
Advanced Radiotherapy Techniques
article

A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy

Xingmin Ma, Qichao Zhou, Wei Zhang, Jian Zhu, Kuo Li
article en

Abstract

BACKGROUND: Conventional volumetric modulated arc therapy (VMAT) is limited by its longitudinal field size for large targets, often requiring multiple isocenters, while Helical Tomotherapy (HT) offers superior longitudinal conformity but suffers from prolonged treatment times due to its narrow fan beam. PURPOSE: This simulation study proposes a novel spiral volumetric modulated arc therapy (SVMAT) technique designed to bridge this gap by synergizing continuous couch movement with dynamic MLC modulation. METHODS: The SVMAT technique was implemented on a model of ring-gantry linac with dual-layer staggered MLC. Its core is a direct aperture optimization algorithm that discretizes the delivery path into finite projections, concurrently optimizing MLC aperture, monitor unit weight, gantry angle, and couch position. A comprehensive dosimetric and efficiency comparison was conducted against state-of-the-art VMAT and HT plans for three clinically challenging scenarios: hippocampal-sparing whole-brain radiotherapy (HS-WBRT), bilateral breast radiotherapy (BBRT), and craniospinal irradiation (CSI), including a pediatric subgroup. RESULTS: by 36.1%. Also, the pediatric CSI analysis confirmed these benefits, with SVMAT significantly reducing doses to developing organs. Regarding efficiency, SVMAT's beam on time was significantly shorter than HT's across all plans (reductions of 33.1% to 55.3%) and was comparable to the multi-isocenter VMAT in CSI. CONCLUSIONS: The SVMAT technique successfully integrates the dynamic delivery of VMAT with the longitudinal integration and single-isocenter capability of HT. By offering enhanced OAR sparing and reduced treatment times, SVMAT represents a significant advancement in radiotherapy, showing immense potential for improving outcomes, especially in vulnerable populations such as pediatric patients.

Medical PhysicsVol. 53(4)
Shandong Tumor Hospital (CN), Centre Français de Recherche en Sciences Sociales (CZ), Shandong First Medical University (CN), Fujian Fisheries Research Institute (CN)
Key Technology Research and Development Program of Shandong
Openalex Percentile: Top 23%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.