Abstract 7730: A novel ultra-sensitive qPCR-based liquid biopsy assay: ESR1 mutation detection in peripheral plasma derived cfDNA

Abstract Background: ESR1 mutations are a leading cause of acquired resistance to endocrine therapy in HR+/HER2- metastatic breast cancer (mBC). Monitoring of ESR1 mutations’ dynamic accumulations is critical for patients to quickly switch to effective selective estrogen receptor degrader (SERD) treatment. Therefore, a rapid and cost-effective assay for ESR1 mutations status monitoring is in urgent demand in clinical practice. Methods: ESR1 sequence with consecutive mutations poses a major hurdle for conventional qPCR assay development. Here an Innovative Suppression Probe PCR was designed and assay was successfully developed (Eq-PCR). Genomic cell-free DNA samples which were extracted from ESR1 mutated breast cancer cell lines (n=47) and patient-derived peripheral blood samples (n=25) were subjected to Eq-PCR, ddPCR (digital droplet PCR) and Next generation sequencing (NGS covering 78 genes). Results: Our Eq-PCR assay has a limit of detection of 0.5% mutation frequency for major ESR1 mutations. For 47 cell lines samples (10ng DNA input), overall agreement between Eq-PCR and ddPCR is 100%. For 25 samples collected from mBC patients(cfDNA concentration ranged from 0.2ng-0.8ng/μl), overall agreement between Eq-PCR and NGS is 100.0% of PPV (5 positive samples) and 85.0% of NPV (20 negative samples). Conclusion: A novel, cost-effective qPCR-based assay for major ESR1 mutations was developed with top accuracy and quick turn-around time. This assay provides an urgently needed clinical tool to monitor critical ESR1 mutation in HR+/HER2- mBC patients in a convenient, timely and cost-effective fashion. Citation Format: Fei Ma, Haili Qian, Wenna Wang, Yongpan Yan, Bowen Ji, Yuwei Pei. A novel ultra-sensitive qPCR-based liquid biopsy assay: ESR1 mutation detection in peripheral plasma derived cfDNA [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 7730.

Authors

Institutions

Publication Details

Journal
Cancer Research
Published
2026-04-03
DOI
https://doi.org/10.1158/1538-7445.am2026-7730
Primary Topic
Advanced Breast Cancer Therapies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 7730: A novel ultra-sensitive qPCR-based liquid biopsy assay: ESR1 mutation detection in peripheral plasma derived cfDNA

Yu Yan, Haili Qian, Wenna Wang, Bowen Ji et al.
Cancer Research
Advanced Breast Cancer Therapies
article

Abstract 7730: A novel ultra-sensitive qPCR-based liquid biopsy assay: ESR1 mutation detection in peripheral plasma derived cfDNA

Yu Yan, Haili Qian, Wenna Wang, Bowen Ji, Fei Ma, Yuwei Pei
article en

Abstract

Abstract Background: ESR1 mutations are a leading cause of acquired resistance to endocrine therapy in HR+/HER2- metastatic breast cancer (mBC). Monitoring of ESR1 mutations’ dynamic accumulations is critical for patients to quickly switch to effective selective estrogen receptor degrader (SERD) treatment. Therefore, a rapid and cost-effective assay for ESR1 mutations status monitoring is in urgent demand in clinical practice. Methods: ESR1 sequence with consecutive mutations poses a major hurdle for conventional qPCR assay development. Here an Innovative Suppression Probe PCR was designed and assay was successfully developed (Eq-PCR). Genomic cell-free DNA samples which were extracted from ESR1 mutated breast cancer cell lines (n=47) and patient-derived peripheral blood samples (n=25) were subjected to Eq-PCR, ddPCR (digital droplet PCR) and Next generation sequencing (NGS covering 78 genes). Results: Our Eq-PCR assay has a limit of detection of 0.5% mutation frequency for major ESR1 mutations. For 47 cell lines samples (10ng DNA input), overall agreement between Eq-PCR and ddPCR is 100%. For 25 samples collected from mBC patients(cfDNA concentration ranged from 0.2ng-0.8ng/μl), overall agreement between Eq-PCR and NGS is 100.0% of PPV (5 positive samples) and 85.0% of NPV (20 negative samples). Conclusion: A novel, cost-effective qPCR-based assay for major ESR1 mutations was developed with top accuracy and quick turn-around time. This assay provides an urgently needed clinical tool to monitor critical ESR1 mutation in HR+/HER2- mBC patients in a convenient, timely and cost-effective fashion. Citation Format: Fei Ma, Haili Qian, Wenna Wang, Yongpan Yan, Bowen Ji, Yuwei Pei. A novel ultra-sensitive qPCR-based liquid biopsy assay: ESR1 mutation detection in peripheral plasma derived cfDNA [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 7730.

Cancer ResearchVol. 86(7_Supplement)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Beijing VDJBio (China) (CN)
Openalex Percentile: Top 5%
Advanced Breast Cancer Therapies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.