Abstract 7830: Transport under various conditions: Evaluating blood sample stability across seasons.

Abstract INTRODUCTION: For analysis of circulating cell-free DNA (ccfDNA) in cancer screening or monitoring, specialized blood collection tubes - such as the PAXgene® Blood ccfDNA Tube (PreAnalytiX) - offer a reliable solution for users who are unable to process samples within 4 hours of collection. These tubes stabilize ccfDNA profiles by preventing blood cells from releasing genomic DNA (gDNA) during transport, thereby preserving sample integrity for sensitive downstream ccfDNA analyses. According to international standards and regulations (ISO 20186-3:2019, (EU) 2017/746 on In Vitro Diagnostic Medical Devices) preanalytical conditions like sample collection, transport, and storage must be validated to ensure that the quality of ccfDNA is maintained. Here, we evaluated sample packaging, temperature fluctuations during transit, and the impact of shipment on downstream assay performance to assess whether blood samples in PAXgene tubes can be transported at ambient temperature. METHODS: Blood was collected from 30 apparently healthy consented donors into PAXgene Blood ccfDNA Tubes. Filled tubes were processed within 4 hours after phlebotomy or stored refrigerated (2-8°C), at 15°C or at room temperature (15-25°C) for 10 days and at 30°C for 7 days. For international transport tubes were shipped from the collection site (QIAGEN, Hilden, Germany) to an external processing site (BD, Franklin Lakes, USA). Samples were placed in insulated boxes compliant with IATA standards and without active temperature control. This included a leakproof triple packaging concept with a primary receptacle, a secondary package, and a rigid outer package. Upon arrival, blood samples were processed directly or subjected to an additional transport simulation test according to requirements defined in the standard ASTM D4169. Plasma and cellular fraction were separated, frozen and shipped back to QIAGEN for ccfDNA and gDNA extraction and analysis. RESULTS: Temperature fluctuations during transport were in the range of 18-35°C during summer and 7-25°C during winter. Additional drop, vibration and altitude tests to simulate transportation by truck, rail and air did not compromise yield or quality of DNA. The relative yield of ccfDNA from plasma, measured by qPCR, between samples processed immediately and after storage or transport and simulation was only slightly increased with mean values between 1.0- to 1.3-fold. gDNA yield and purity measured by spectrophotometry were high for all conditions in the range of 26 to 55 µg of gDNA per mL of cellular fraction and mean 260/280 ratios between 1.80 and 1.82. CONCLUSION: Excellent sample stability could be demonstrated in whole blood samples collected into PAXgene Blood ccfDNA Tubes under both controlled storage and real-world transport conditions. The data confirm that sample integrity is maintained following air and ground transportation at ambient temperatures across both summer and winter seasons. Citation Format: Daniel Grölz, Markus Wolf, Daniela Mancarella-Langer, Franziska Kaiser, Michelle Walther, Eric Provencer. Transport under various conditions: Evaluating blood sample stability across seasons [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 7830.

Authors

Institutions

Publication Details

Journal
Cancer Research
Published
2026-04-03
DOI
https://doi.org/10.1158/1538-7445.am2026-7830
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 7830: Transport under various conditions: Evaluating blood sample stability across seasons.

Franziska Kaiser, Daniel Grölz, Markus Wolf, Daniela Mancarella-Langer et al.
Cancer Research
Biosensors and Analytical Detection
article

Abstract 7830: Transport under various conditions: Evaluating blood sample stability across seasons.

Franziska Kaiser, Daniel Grölz, Markus Wolf, Daniela Mancarella-Langer, Eric Provencer, Michelle Walther
article en

Abstract

Abstract INTRODUCTION: For analysis of circulating cell-free DNA (ccfDNA) in cancer screening or monitoring, specialized blood collection tubes - such as the PAXgene® Blood ccfDNA Tube (PreAnalytiX) - offer a reliable solution for users who are unable to process samples within 4 hours of collection. These tubes stabilize ccfDNA profiles by preventing blood cells from releasing genomic DNA (gDNA) during transport, thereby preserving sample integrity for sensitive downstream ccfDNA analyses. According to international standards and regulations (ISO 20186-3:2019, (EU) 2017/746 on In Vitro Diagnostic Medical Devices) preanalytical conditions like sample collection, transport, and storage must be validated to ensure that the quality of ccfDNA is maintained. Here, we evaluated sample packaging, temperature fluctuations during transit, and the impact of shipment on downstream assay performance to assess whether blood samples in PAXgene tubes can be transported at ambient temperature. METHODS: Blood was collected from 30 apparently healthy consented donors into PAXgene Blood ccfDNA Tubes. Filled tubes were processed within 4 hours after phlebotomy or stored refrigerated (2-8°C), at 15°C or at room temperature (15-25°C) for 10 days and at 30°C for 7 days. For international transport tubes were shipped from the collection site (QIAGEN, Hilden, Germany) to an external processing site (BD, Franklin Lakes, USA). Samples were placed in insulated boxes compliant with IATA standards and without active temperature control. This included a leakproof triple packaging concept with a primary receptacle, a secondary package, and a rigid outer package. Upon arrival, blood samples were processed directly or subjected to an additional transport simulation test according to requirements defined in the standard ASTM D4169. Plasma and cellular fraction were separated, frozen and shipped back to QIAGEN for ccfDNA and gDNA extraction and analysis. RESULTS: Temperature fluctuations during transport were in the range of 18-35°C during summer and 7-25°C during winter. Additional drop, vibration and altitude tests to simulate transportation by truck, rail and air did not compromise yield or quality of DNA. The relative yield of ccfDNA from plasma, measured by qPCR, between samples processed immediately and after storage or transport and simulation was only slightly increased with mean values between 1.0- to 1.3-fold. gDNA yield and purity measured by spectrophotometry were high for all conditions in the range of 26 to 55 µg of gDNA per mL of cellular fraction and mean 260/280 ratios between 1.80 and 1.82. CONCLUSION: Excellent sample stability could be demonstrated in whole blood samples collected into PAXgene Blood ccfDNA Tubes under both controlled storage and real-world transport conditions. The data confirm that sample integrity is maintained following air and ground transportation at ambient temperatures across both summer and winter seasons. Citation Format: Daniel Grölz, Markus Wolf, Daniela Mancarella-Langer, Franziska Kaiser, Michelle Walther, Eric Provencer. Transport under various conditions: Evaluating blood sample stability across seasons [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 7830.

Cancer ResearchVol. 86(7_Supplement)
Matthew Larson Foundation (US), Qiagen (Germany) (DE)
Partnerships for the goals
Openalex Percentile: Top 6%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.