Abstract 6660: CellScape Quality Control (CSQC): A tissue- and protein-agnostic platform for spatial proteomics quality assessment

Abstract Introduction: Spatial proteomics is an emerging diagnostic tool for precision oncology, yet data reproducibility across tissue sections and batches remains a major obstacle towards achieving robust biomarker discovery and clinically actionable results. Variability in tissue quality, tissue preparation, antibody performance, and imaging conditions all introduce artifacts that compromise quantitative accuracy. Manual quality control of imaging data is thus essential, but it is very time consuming and subjective. A standardized, automated, and quantitative quality control framework is therefore essential to support realistic adoption of spatial proteomic workflows in precision oncology. Methods: We developed CellScape Quality Control (CSQC), a machine learning-based framework for automated stain quality assessment and tissue vetting. CSQC was trained on >100 samples from >20 tissue types from ten CellScape™ precise spatial phenotyping instruments across laboratories. The dataset included more than 50 biomarkers representing nuclear, membrane, and cytoplasmic targets across multiple antibody clones, stain protocols, and imaging magnifications (10x and 20x). Expert annotations were used as ground truth for model training and validation. Results: CSQC achieved a mean IoU >0.7 for background, artifact, and usable tissue detection, showing strong concordance with expert annotations. The system automatically flagged suboptimal staining and batch-level artifacts, thereby enabling harmonization across instruments and sites. The deployment of CSQC reduced manual review time from several hours to minutes per sample, and thereby allowed rapid scaling of downstream analyses to dozens of slides and proteins analyzed by a single operator in a given time frame. In addition, we observed a noticeable improvement in downstream marker quantification and reproducibility following CSQC vetting. Conclusion: CSQC provides a standardized, quantitative, and scalable approach to stain and tissue quality control, supporting robust multisite spatial proteomics workflows on the CellScape precise spatial phenotyping platform. This framework facilitates assay harmonization, benchmarked reproducibility, and reliable spatial biomarker discovery for clinical translation. Citation Format: Daniel Jimenez-Sanchez, Brian J. Lane, Matthew H. Ingalls, Charles Eldon Jackson, Steven T. Lott, Adam Northcutt, Arne Christians, Anke Brix, Jennifer Brooks, Oliver Braubach. CellScape Quality Control (CSQC): A tissue- and protein-agnostic platform for spatial proteomics quality assessment [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 6660.

Authors

Institutions

Publication Details

Journal
Cancer Research
Published
2026-04-03
DOI
https://doi.org/10.1158/1538-7445.am2026-6660
Primary Topic
Cell Image Analysis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 6660: CellScape Quality Control (CSQC): A tissue- and protein-agnostic platform for spatial proteomics quality assessment

Oliver Braubach, Adam J. Northcutt, Steven T. Lott, Matthew H. Ingalls et al.
Cancer Research
Cell Image Analysis Techniques
article

Abstract 6660: CellScape Quality Control (CSQC): A tissue- and protein-agnostic platform for spatial proteomics quality assessment

Oliver Braubach, Adam J. Northcutt, Steven T. Lott, Matthew H. Ingalls, Brian J. Lane, Charles Eldon Jackson, Daniel Jiménez-Sánchez, Anke Brix, Jennifer Brooks, Arne Christians
article en

Abstract

Abstract Introduction: Spatial proteomics is an emerging diagnostic tool for precision oncology, yet data reproducibility across tissue sections and batches remains a major obstacle towards achieving robust biomarker discovery and clinically actionable results. Variability in tissue quality, tissue preparation, antibody performance, and imaging conditions all introduce artifacts that compromise quantitative accuracy. Manual quality control of imaging data is thus essential, but it is very time consuming and subjective. A standardized, automated, and quantitative quality control framework is therefore essential to support realistic adoption of spatial proteomic workflows in precision oncology. Methods: We developed CellScape Quality Control (CSQC), a machine learning-based framework for automated stain quality assessment and tissue vetting. CSQC was trained on >100 samples from >20 tissue types from ten CellScape™ precise spatial phenotyping instruments across laboratories. The dataset included more than 50 biomarkers representing nuclear, membrane, and cytoplasmic targets across multiple antibody clones, stain protocols, and imaging magnifications (10x and 20x). Expert annotations were used as ground truth for model training and validation. Results: CSQC achieved a mean IoU >0.7 for background, artifact, and usable tissue detection, showing strong concordance with expert annotations. The system automatically flagged suboptimal staining and batch-level artifacts, thereby enabling harmonization across instruments and sites. The deployment of CSQC reduced manual review time from several hours to minutes per sample, and thereby allowed rapid scaling of downstream analyses to dozens of slides and proteins analyzed by a single operator in a given time frame. In addition, we observed a noticeable improvement in downstream marker quantification and reproducibility following CSQC vetting. Conclusion: CSQC provides a standardized, quantitative, and scalable approach to stain and tissue quality control, supporting robust multisite spatial proteomics workflows on the CellScape precise spatial phenotyping platform. This framework facilitates assay harmonization, benchmarked reproducibility, and reliable spatial biomarker discovery for clinical translation. Citation Format: Daniel Jimenez-Sanchez, Brian J. Lane, Matthew H. Ingalls, Charles Eldon Jackson, Steven T. Lott, Adam Northcutt, Arne Christians, Anke Brix, Jennifer Brooks, Oliver Braubach. CellScape Quality Control (CSQC): A tissue- and protein-agnostic platform for spatial proteomics quality assessment [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 6660.

Cancer ResearchVol. 86(7_Supplement)
Bruker (United States) (US), CRC for Spatial information (AU)
Openalex Percentile: Top 5%
Cell Image Analysis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.