Abstract 7175: Targeting spatial patterns of CAFs and tumor cells for precision stroma-targeted radionuclide therapy

Abstract Stroma-targeted imaging, particularly fibroblast activation protein inhibitor (FAPI) PET-CT, has demonstrated remarkable diagnostic success across multiple cancer types. In contrast, stroma-targeted radionuclide therapy using 177Lu-labeled compounds showed limited clinical efficacy (response rate: 10%-20%), despite achieving sufficient macroscopic accumulation within tumor lesions. We therefore hypothesize that the microscopic spatial organization between cancer-associated fibroblasts (CAFs) and tumor cells critically influences intratumoral distribution and radiation dose deposition of 177Lu at the microscale. The primary objective of this study is to investigate how spatial pattern affects 177Lu distribution and dose deposition, and to experimentally validate the differential therapeutic outcomes across different spatial patterns.Using medullary thyroid carcinoma (MTC) as a representative model, we performed quantitative histopathological analysis of 279 tissue sections from 15 patients through co-registration, automated image segmentation, and spatial distribution profiling. This identified two recurrent spatial patterns: a "surrounding" type, where CAFs form a continuous ring around tumor clusters, and an "infiltrative" type characterized by a reticular CAF network with dispersed tumor nests. These patterns were consistently observed across primary tumors, lymph node metastases, and invasive foci.Monte Carlo simulations revealed highly heterogeneous 177Lu dose distributions across spatial patterns. While infiltrative lesions showed effective dose delivery, surrounding lesions exhibited dose deposition primarily confined to CAF-rich peripheries. We established biologically relevant 3D bioprinted models mimicking both patterns using 6% GelMA 30 hydrogel, which matches human thyroid mechanical properties (10-20 kPa). Immunohistochemical and immunofluorescence analyses confirmed biological fidelity. Autoradiography with [177Lu]Lu-FS-86 demonstrated distinct uptake patterns - concentrated in CAF rings (surrounding) versus homogeneous distribution (infiltrative) - validating functional relevance. These models confirmed that the infiltrative pattern allowed homogeneous dose distribution of 177Lu and significant cell death, whereas the surrounding type exhibited limited penetration and limited response. Importantly, we observed consistent therapeutic outcomes across multiple cancer types including lung, liver, breast, and medullary thyroid carcinomas, indicating that stroma-targeted radionuclide efficacy is spatial pattern-dependent rather than tumor type-dependent. The establishment of this spatial classification system provides a framework for identifying optimal stroma-targeting radionuclides based on distinct spatial patterns, demonstrating significant potential for clinical translation. Citation Format: Yuning Sun, Ye Yang, Guanyu Zhu, Jiangang Zhang, Xiaowei Fan, Jian Wang, Yang Liu, Shaoyan Liu, Yansong Lin, Xi-Yang Cui, Zhibo Liu, Ziren Kong. Targeting spatial patterns of CAFs and tumor cells for precision stroma-targeted radionuclide therapy [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 7175.

Authors

Institutions

Publication Details

Journal
Cancer Research
Published
2026-04-03
DOI
https://doi.org/10.1158/1538-7445.am2026-7175
Primary Topic
Peptidase Inhibition and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 7175: Targeting spatial patterns of CAFs and tumor cells for precision stroma-targeted radionuclide therapy

Yuning Sun, Xi‐Yang Cui, Ziren Kong, Ya Lin et al.
Cancer Research
Peptidase Inhibition and Analysis
article

Abstract 7175: Targeting spatial patterns of CAFs and tumor cells for precision stroma-targeted radionuclide therapy

Yuning Sun, Xi‐Yang Cui, Ziren Kong, Ya Lin, Xiaowei Fan, Zhibo Liu, Jiangang Zhang, Ye Yang, Shaoyan Liu, Yang Liu, Jian Wang, Guanyu Zhu
article en

Abstract

Abstract Stroma-targeted imaging, particularly fibroblast activation protein inhibitor (FAPI) PET-CT, has demonstrated remarkable diagnostic success across multiple cancer types. In contrast, stroma-targeted radionuclide therapy using 177Lu-labeled compounds showed limited clinical efficacy (response rate: 10%-20%), despite achieving sufficient macroscopic accumulation within tumor lesions. We therefore hypothesize that the microscopic spatial organization between cancer-associated fibroblasts (CAFs) and tumor cells critically influences intratumoral distribution and radiation dose deposition of 177Lu at the microscale. The primary objective of this study is to investigate how spatial pattern affects 177Lu distribution and dose deposition, and to experimentally validate the differential therapeutic outcomes across different spatial patterns.Using medullary thyroid carcinoma (MTC) as a representative model, we performed quantitative histopathological analysis of 279 tissue sections from 15 patients through co-registration, automated image segmentation, and spatial distribution profiling. This identified two recurrent spatial patterns: a "surrounding" type, where CAFs form a continuous ring around tumor clusters, and an "infiltrative" type characterized by a reticular CAF network with dispersed tumor nests. These patterns were consistently observed across primary tumors, lymph node metastases, and invasive foci.Monte Carlo simulations revealed highly heterogeneous 177Lu dose distributions across spatial patterns. While infiltrative lesions showed effective dose delivery, surrounding lesions exhibited dose deposition primarily confined to CAF-rich peripheries. We established biologically relevant 3D bioprinted models mimicking both patterns using 6% GelMA 30 hydrogel, which matches human thyroid mechanical properties (10-20 kPa). Immunohistochemical and immunofluorescence analyses confirmed biological fidelity. Autoradiography with [177Lu]Lu-FS-86 demonstrated distinct uptake patterns - concentrated in CAF rings (surrounding) versus homogeneous distribution (infiltrative) - validating functional relevance. These models confirmed that the infiltrative pattern allowed homogeneous dose distribution of 177Lu and significant cell death, whereas the surrounding type exhibited limited penetration and limited response. Importantly, we observed consistent therapeutic outcomes across multiple cancer types including lung, liver, breast, and medullary thyroid carcinomas, indicating that stroma-targeted radionuclide efficacy is spatial pattern-dependent rather than tumor type-dependent. The establishment of this spatial classification system provides a framework for identifying optimal stroma-targeting radionuclides based on distinct spatial patterns, demonstrating significant potential for clinical translation. Citation Format: Yuning Sun, Ye Yang, Guanyu Zhu, Jiangang Zhang, Xiaowei Fan, Jian Wang, Yang Liu, Shaoyan Liu, Yansong Lin, Xi-Yang Cui, Zhibo Liu, Ziren Kong. Targeting spatial patterns of CAFs and tumor cells for precision stroma-targeted radionuclide therapy [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 7175.

Cancer ResearchVol. 86(7_Supplement)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Beijing National Laboratory for Molecular Sciences (CN)
Good health and well-being
Openalex Percentile: Top 34%
Peptidase Inhibition and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.