Novel reference gene microseminoprotein‐beta based prostate cancer antigen 3 urine test: Enhanced diagnostic performance for prostate cancer and feasibility of non‐digital rectal examination urine sampling

Abstract Background The diagnosis of prostate cancer (PCa) is limited by low specificity and invasiveness. This study aims to establish a highly accurate, noninvasive reverse transcription‐quantitative polymerase chain reaction (RT‐qPCR)‐based urinary prostate cancer antigen 3 ( PCA3 ) assay system and explore the feasibility of using first‐morning urine instead of post‐digital rectal examination (DRE) samples. Methods Three prospective multicenter cohort studies were conducted on 643 Chinese men. Urine PCA3 expression was quantified by RT‐qPCR, using either the novel reference gene microseminoprotein‐beta ( MSMB ) or conventional kallikrein‐related peptidase 3 ( KLK3 , encoding prostate‐specific antigen, PSA). Diagnostic performance was evaluated through receiver operating characteristic (ROC) analysis in Cohort I ( n = 176), with validation in Cohort II ( n = 350). In Cohort III ( n = 117), the diagnostic accuracy of PCA3 / MSMB test was compared between DRE and non‐DRE urine samples. Results The PCA3 / MSMB RT‐qPCR system showed high precision and stability. In Cohort I, the PCA3 / MSMB test demonstrated superior diagnostic performance compared with the PCA3 / KLK3 test, with a significantly higher area under the receiver operating characteristic curve (AUC) (0.869 vs. 0.830, p = 0.0468), higher sensitivity (82.1% vs. 79.0%), and higher specificity (77.8% vs. 74.1%). Cohort II confirmed these results, yielding a sensitivity of 82.63% and a specificity of 77.50%. In Cohort III, no significant difference in diagnostic performance was observed between non‐DRE and DRE urine samples (AUC 0.859 vs. 0.850, p = 0.6262), suggesting the potential for simplified sample collection. Conclusion The PCA3 / MSMB urine test is a promising noninvasive diagnostic tool for PCa; it can reduce unnecessary biopsies and improve detection accuracy using non‐DRE urine samples.

Authors

Institutions

Publication Details

Journal
UroPrecision
Published
2026-04-02
DOI
https://doi.org/10.1002/uro2.70060
Primary Topic
Molecular Biology Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel reference gene microseminoprotein‐beta based prostate cancer antigen 3 urine test: Enhanced diagnostic performance for prostate cancer and feasibility of non‐digital rectal examination urine sampling

Liu Yang, Cong Shi, Yiwei Jiang, Xiuzhi Duan et al.
UroPrecision
Molecular Biology Techniques and Applications
article

Novel reference gene microseminoprotein‐beta based prostate cancer antigen 3 urine test: Enhanced diagnostic performance for prostate cancer and feasibility of non‐digital rectal examination urine sampling

Liu Yang, Cong Shi, Yiwei Jiang, Xiuzhi Duan, Xiaobing Dou, Jianglei Xu, Y Xie, Xuchu Wang, Jing Chen, Xian Wang, Jianzhong Jiang, Xuejuan Gao, Zhihua Tao, Chunyu Jin, Xiaoxiao Sun, Zhixian Yu
article en

Abstract

Abstract Background The diagnosis of prostate cancer (PCa) is limited by low specificity and invasiveness. This study aims to establish a highly accurate, noninvasive reverse transcription‐quantitative polymerase chain reaction (RT‐qPCR)‐based urinary prostate cancer antigen 3 ( PCA3 ) assay system and explore the feasibility of using first‐morning urine instead of post‐digital rectal examination (DRE) samples. Methods Three prospective multicenter cohort studies were conducted on 643 Chinese men. Urine PCA3 expression was quantified by RT‐qPCR, using either the novel reference gene microseminoprotein‐beta ( MSMB ) or conventional kallikrein‐related peptidase 3 ( KLK3 , encoding prostate‐specific antigen, PSA). Diagnostic performance was evaluated through receiver operating characteristic (ROC) analysis in Cohort I ( n = 176), with validation in Cohort II ( n = 350). In Cohort III ( n = 117), the diagnostic accuracy of PCA3 / MSMB test was compared between DRE and non‐DRE urine samples. Results The PCA3 / MSMB RT‐qPCR system showed high precision and stability. In Cohort I, the PCA3 / MSMB test demonstrated superior diagnostic performance compared with the PCA3 / KLK3 test, with a significantly higher area under the receiver operating characteristic curve (AUC) (0.869 vs. 0.830, p = 0.0468), higher sensitivity (82.1% vs. 79.0%), and higher specificity (77.8% vs. 74.1%). Cohort II confirmed these results, yielding a sensitivity of 82.63% and a specificity of 77.50%. In Cohort III, no significant difference in diagnostic performance was observed between non‐DRE and DRE urine samples (AUC 0.859 vs. 0.850, p = 0.6262), suggesting the potential for simplified sample collection. Conclusion The PCA3 / MSMB urine test is a promising noninvasive diagnostic tool for PCa; it can reduce unnecessary biopsies and improve detection accuracy using non‐DRE urine samples.

UroPrecision
Zhejiang Chinese Medical University (CN), Sichuan University (CN), Wenzhou Medical University (CN), First Affiliated Hospital of Wenzhou Medical University (CN), The Fourth People's Hospital (CN), West China Hospital of Sichuan University (CN), Hangzhou DAC Biotech (China) (CN), Second Affiliated Hospital of Zhejiang University (CN)
Good health and well-being
Openalex Percentile: Top 9%
Molecular Biology Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.