One-step material decomposition using spectral diffusion posterior sampling in sparse-view dual-layer CT

Spectral X-ray imaging technology can enhance interventional imaging by providing material-specific information. However, typical interventional systems with cone beam CT (CBCT) face limitations in scan range and acquisition speed, making sparse-view imaging an attractive option for faster, lower-dose scans, although sparse data pose greater challenges for accurate material quantification. We previously proposed a Spectral Diffusion Posterior Sampling (Spectral DPS) framework for generalizable one-step material decomposition, which integrates a learned diffusion prior with a physics-based forward model. The approach requires only a single unconditional training while providing flexibility of application across different system configurations. In this work, we investigate the performance of Spectral DPS on a physical dual-layer CBCT system under different sparse-view conditions. Specifically, an anthropomorphic head phantom was scanned on a bench-top CBCT system equipped with a dual-layer flat-panel detector, and one-step material decomposition was performed using Spectral DPS with the number of projections ranging from 720 down to 45 views. Results demonstrate that Spectral DPS can achieve accurate water-bone separation, and maintains uniform soft tissue appearance even though such homogeneous regions represent an out-of-distribution condition. Decomposition results remain robust down to 120 views, with minimal loss of structural detail and quantitative accuracy. At more extreme sparsity, Spectral DPS exhibits increased variability and artifacts, though bony structures remain discernible at as few as 90 views. These findings highlight the potential of Spectral DPS to enable accurate and robust material decomposition under certain sparse-view acquisitions for interventional CBCT imaging.

Authors

Institutions

Publication Details

Published
2026-04-02
DOI
https://doi.org/10.1117/12.3087781
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-step material decomposition using spectral diffusion posterior sampling in sparse-view dual-layer CT

Yue Fan, Zimo Liu, Grace J. Gang, J. Webster Stayman et al.
Advanced X-ray and CT Imaging
article

One-step material decomposition using spectral diffusion posterior sampling in sparse-view dual-layer CT

Yue Fan, Zimo Liu, Grace J. Gang, J. Webster Stayman, Xiao Jiang
article en

Abstract

Spectral X-ray imaging technology can enhance interventional imaging by providing material-specific information. However, typical interventional systems with cone beam CT (CBCT) face limitations in scan range and acquisition speed, making sparse-view imaging an attractive option for faster, lower-dose scans, although sparse data pose greater challenges for accurate material quantification. We previously proposed a Spectral Diffusion Posterior Sampling (Spectral DPS) framework for generalizable one-step material decomposition, which integrates a learned diffusion prior with a physics-based forward model. The approach requires only a single unconditional training while providing flexibility of application across different system configurations. In this work, we investigate the performance of Spectral DPS on a physical dual-layer CBCT system under different sparse-view conditions. Specifically, an anthropomorphic head phantom was scanned on a bench-top CBCT system equipped with a dual-layer flat-panel detector, and one-step material decomposition was performed using Spectral DPS with the number of projections ranging from 720 down to 45 views. Results demonstrate that Spectral DPS can achieve accurate water-bone separation, and maintains uniform soft tissue appearance even though such homogeneous regions represent an out-of-distribution condition. Decomposition results remain robust down to 120 views, with minimal loss of structural detail and quantitative accuracy. At more extreme sparsity, Spectral DPS exhibits increased variability and artifacts, though bony structures remain discernible at as few as 90 views. These findings highlight the potential of Spectral DPS to enable accurate and robust material decomposition under certain sparse-view acquisitions for interventional CBCT imaging.

Vol. 13924
Johns Hopkins University (US), Johns Hopkins Medicine (US), University of Pennsylvania (US)
Climate action
Openalex Percentile: Top 27%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.