Stability evaluation of a double crystal monochromator using an optical linear encoder

A dedicated jig with an optical linear encoder was developed to evaluate the pitching stability between the first and second crystals of a double crystal monochromator in a standalone configuration. This method does not require synchrotron radiation, enabling direct assessment of the monochromator's intrinsic stability. Unlike beamline-based measurements influenced by upstream optics, this approach isolates the monochromator's performance. Designed and implemented by Kohzu Precision, the system is currently applied to a symmetrical layout monochromator to assess angular stability in mechanically decoupled configurations. The encoder counter supports readout rates up to 12 MHz; however, considering the latch interval of the system, the effective sampling rate is about 5 kHz. Measurements were conducted at approximately 2 kHz. At a Bragg angle of 10 degrees, the angular stability (RMS) in the pitching direction was better than 20 nrad, and a dominant vibration peak was observed near 180 Hz. These results demonstrate the system's effectiveness in characterizing the stability of high-performance monochromator configurations.

Authors

Publication Details

Journal
JACOW
Published
2026-04-02
DOI
https://doi.org/10.18429/jacow-medsi2025-thp52
Primary Topic
Crystallography and Radiation Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability evaluation of a double crystal monochromator using an optical linear encoder

Naoki Yato, Yuki Ikeya, Atsushi Shimoguchi, Daiki Nagata et al.
JACOW
Crystallography and Radiation Phenomena
article

Stability evaluation of a double crystal monochromator using an optical linear encoder

Naoki Yato, Yuki Ikeya, Atsushi Shimoguchi, Daiki Nagata, H. Fukuzawa, Masato Okui, Hiroyuki Yamane, Tetsuya Nakamura, Junya Yoshida
article en

Abstract

A dedicated jig with an optical linear encoder was developed to evaluate the pitching stability between the first and second crystals of a double crystal monochromator in a standalone configuration. This method does not require synchrotron radiation, enabling direct assessment of the monochromator's intrinsic stability. Unlike beamline-based measurements influenced by upstream optics, this approach isolates the monochromator's performance. Designed and implemented by Kohzu Precision, the system is currently applied to a symmetrical layout monochromator to assess angular stability in mechanically decoupled configurations. The encoder counter supports readout rates up to 12 MHz; however, considering the latch interval of the system, the effective sampling rate is about 5 kHz. Measurements were conducted at approximately 2 kHz. At a Bragg angle of 10 degrees, the angular stability (RMS) in the pitching direction was better than 20 nrad, and a dominant vibration peak was observed near 180 Hz. These results demonstrate the system's effectiveness in characterizing the stability of high-performance monochromator configurations.

JACOW
Affordable and clean energy
Openalex Percentile: Top 28%
Crystallography and Radiation Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.