Real-Time Non-Uniformity Correction Method for 800 FPS High-Frame-Rate Short-Wave Infrared Images

In conventional infrared imaging systems, non-uniformity correction typically involves continuously reading correction parameters from double data rate (DDR) memory. For high-frame-rate short-wave infrared imaging systems to achieve real-time non-uniformity correction, it is essential to minimize the reading time of correction parameters. Due to the narrow dynamic range of two-point correction and the large parameter storage required by two-point multi-segment correction, it is difficult to simultaneously achieve good correction performance and short parameter reading time under limited hardware resources. To address the above issues, this paper proposes a real-time non-uniformity correction method suitable for high-frame-rate short-wave infrared images. Based on a field-programmable gate array (FPGA), improvements are made to quadratic polynomial correction through the design of quantization methods for different parameters to enhance storage bit-width utilization; dynamic allocation of bit-widths between parameters to improve correction performance; and ping-pong buffering for DDR reading to avoid the impact of DDR read latency on parameter reading time. The storage size of the improved correction parameters is comparable to that of conventional two-point correction. Experiments were conducted on a hardware system based on the XC7A100T-2FGG484I FPGA. The experimental results show that the average non-uniformity of images after the improved quadratic polynomial correction is 0.4818%, significantly better than 0.5930% after two-point correction and slightly better than 0.4891% after two-point eight-segment correction. Blind pixel compensation was completed simultaneously with the correction. Using a 640 × 512 area array InGaAs short-wave infrared detector, the highest real-time processing frame rate reaches 800 frames per second (FPS).

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-02
DOI
https://doi.org/10.3390/s26072209
Primary Topic
Infrared Target Detection Methodologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Non-Uniformity Correction Method for 800 FPS High-Frame-Rate Short-Wave Infrared Images

Daogang He, Yueming Wang, Guiguang Su
Sensors
Infrared Target Detection Methodologies
article

Real-Time Non-Uniformity Correction Method for 800 FPS High-Frame-Rate Short-Wave Infrared Images

Daogang He, Yueming Wang, Guiguang Su
article en

Abstract

In conventional infrared imaging systems, non-uniformity correction typically involves continuously reading correction parameters from double data rate (DDR) memory. For high-frame-rate short-wave infrared imaging systems to achieve real-time non-uniformity correction, it is essential to minimize the reading time of correction parameters. Due to the narrow dynamic range of two-point correction and the large parameter storage required by two-point multi-segment correction, it is difficult to simultaneously achieve good correction performance and short parameter reading time under limited hardware resources. To address the above issues, this paper proposes a real-time non-uniformity correction method suitable for high-frame-rate short-wave infrared images. Based on a field-programmable gate array (FPGA), improvements are made to quadratic polynomial correction through the design of quantization methods for different parameters to enhance storage bit-width utilization; dynamic allocation of bit-widths between parameters to improve correction performance; and ping-pong buffering for DDR reading to avoid the impact of DDR read latency on parameter reading time. The storage size of the improved correction parameters is comparable to that of conventional two-point correction. Experiments were conducted on a hardware system based on the XC7A100T-2FGG484I FPGA. The experimental results show that the average non-uniformity of images after the improved quadratic polynomial correction is 0.4818%, significantly better than 0.5930% after two-point correction and slightly better than 0.4891% after two-point eight-segment correction. Blind pixel compensation was completed simultaneously with the correction. Using a 640 × 512 area array InGaAs short-wave infrared detector, the highest real-time processing frame rate reaches 800 frames per second (FPS).

SensorsVol. 26(7)
Chinese Academy of Sciences (CN), Shanghai Institute of Technical Physics (CN), University of Chinese Academy of Sciences (CN)
Quality Education
Openalex Percentile: Top 21%
Infrared Target Detection Methodologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.