Nano-tomo-ptychography 3D-imaging on Swing Beamline

In 2018, a new Nanoprobe system was installed and validated on the SWING beamline (Synchrotron SOLEIL) for 2D-nano-ptychography with an expected imaging resolution of 40 nm. The setup had been designed to be portable and capable of handling multiscale sample-sizes (from micrometer to hundreds of a micrometer). This system was then successively upgraded to allow for 2D-imaging resolutions of 20 nm, and 3D-nano-tomo-ptychography imaging with spatial resolutions of 50 nm. The end-station is composed of: a sample stage (5DOF), an optical stage comprised of a central stop and a Fresnel zone plate optical (3DOF), an order sorting aperture stage (3DOF). All positioning stages comprise piezo-driven actuators, of which synchronized control (with kinematic modelling) is done using the SOLEIL Delta Tau platform. In addition, fibber interferometry feedback was used for image reconstruction purposes. After the last improvements in 2023, imaging results show that the system can resolve 3D-images with a spatial resolution of 31 nm using a teeth sample (18h of acquisition). This contribution will present an overview of the mechanical design concepts and solutions adopted for the Nanoprobe project.

Authors

Publication Details

Journal
JACOW
Published
2026-04-02
DOI
https://doi.org/10.18429/jacow-medsi2025-tup45
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nano-tomo-ptychography 3D-imaging on Swing Beamline

Thomas Bizien, Arnaud Gibert, Felisa Berenguer, Christer Engblom et al.
JACOW
Advanced X-ray Imaging Techniques
article

Nano-tomo-ptychography 3D-imaging on Swing Beamline

Thomas Bizien, Arnaud Gibert, Felisa Berenguer, Christer Engblom, Filipe S. Alves, Florent Langlois, Yves-Marie Abiven, Alain Lestrade, Javier Perez
article en

Abstract

In 2018, a new Nanoprobe system was installed and validated on the SWING beamline (Synchrotron SOLEIL) for 2D-nano-ptychography with an expected imaging resolution of 40 nm. The setup had been designed to be portable and capable of handling multiscale sample-sizes (from micrometer to hundreds of a micrometer). This system was then successively upgraded to allow for 2D-imaging resolutions of 20 nm, and 3D-nano-tomo-ptychography imaging with spatial resolutions of 50 nm. The end-station is composed of: a sample stage (5DOF), an optical stage comprised of a central stop and a Fresnel zone plate optical (3DOF), an order sorting aperture stage (3DOF). All positioning stages comprise piezo-driven actuators, of which synchronized control (with kinematic modelling) is done using the SOLEIL Delta Tau platform. In addition, fibber interferometry feedback was used for image reconstruction purposes. After the last improvements in 2023, imaging results show that the system can resolve 3D-images with a spatial resolution of 31 nm using a teeth sample (18h of acquisition). This contribution will present an overview of the mechanical design concepts and solutions adopted for the Nanoprobe project.

JACOW
Openalex Percentile: Top 4%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.