Cryogenic radiometry: a new absorber for X-rays up to 150 keV

The accurate measurement of radiant power is essential for the calibration of X-ray detectors, such as silicon photodiodes. Cryogenic electrical substitution radiometers (ESRs) perform high accuracy, absolute, measurements of radiant power. Material and geometry of the absorber in an ESR are chosen to maximize the absorption in the energy range of interest, while providing a high thermal response and a short time constant. The highest energy design previously reported allowed the measurement of X-rays up to 60 keV. In this work we present a new absorber developed at the Canadian Light Source for energies from 25 keV to 150 keV. Monte Carlo simulations led to a design with an absorption > 99% in the entire energy range while considering all losses due to fluorescence and scattering. Measurements have been successfully performed at the Biomedical Imaging and Therapy beamline (05ID-2), which has a 3.7 T wiggler source and provides X-ray energies up to 150 keV.

Authors

Publication Details

Journal
JACOW
Published
2026-04-02
DOI
https://doi.org/10.18429/jacow-medsi2025-weob03
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cryogenic radiometry: a new absorber for X-rays up to 150 keV

J. Vogt, Omar Renzo Piminchumo Marinos
JACOW
Radiation Therapy and Dosimetry
article

Cryogenic radiometry: a new absorber for X-rays up to 150 keV

J. Vogt, Omar Renzo Piminchumo Marinos
article en

Abstract

The accurate measurement of radiant power is essential for the calibration of X-ray detectors, such as silicon photodiodes. Cryogenic electrical substitution radiometers (ESRs) perform high accuracy, absolute, measurements of radiant power. Material and geometry of the absorber in an ESR are chosen to maximize the absorption in the energy range of interest, while providing a high thermal response and a short time constant. The highest energy design previously reported allowed the measurement of X-rays up to 60 keV. In this work we present a new absorber developed at the Canadian Light Source for energies from 25 keV to 150 keV. Monte Carlo simulations led to a design with an absorption > 99% in the entire energy range while considering all losses due to fluorescence and scattering. Measurements have been successfully performed at the Biomedical Imaging and Therapy beamline (05ID-2), which has a 3.7 T wiggler source and provides X-ray energies up to 150 keV.

JACOW
Affordable and clean energy
Openalex Percentile: Top 6%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.