Comparative Evaluation of Tissue and Systemic Responses to Electrospun Biodegradable Polymer and Polypropylene Implants Using hs-CRP and Immunohistochemical Markers

The use of biodegradable polymers for the surgical reinforcement of musculofascial structures is of considerable practical interest. Research into the applicability of biopolymers should be conducted in comparison with polypropylene, a material used in surgery. Using highly sensitive C-reactive protein (hs-CRP) in blood and interleukin-6 (IL-6) and CD34 (an endothelial marker with angiogenic properties) in tissues, we analyzed the systemic and local tissue responses to polypropylene and biodegradable polymer implantation in 42 laboratory rats over a three-month period. The study confirmed good biocompatibility of both polymers. However, the systemic and tissue responses to the biopolymer, as measured by the studied markers, were significantly less pronounced compared to polypropylene. Persistently elevated levels of hs-CRP and CD34-positive cells in the biopolymer group at three months post-implantation were attributed to ongoing biotransformation processes. The mild inflammatory response following biopolymer implantation confirms not only its bioinert properties but also its potential for practical surgical applications. Elevated levels of hs-CRP and CD34-, as well as IL-6-positive cells in the polypropylene group, warrant further investigation of long-term responses to polypropylene as potential contributors to post-implantation complications. The hs-CRP level correlated with tissue markers IL-6 and CD34, suggesting its utility as a criterion for assessing postoperative adaptation to implanted synthetic materials.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2026-04-02
DOI
https://doi.org/10.3390/ijms27073231
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Tissue and Systemic Responses to Electrospun Biodegradable Polymer and Polypropylene Implants Using hs-CRP and Immunohistochemical Markers

Igor A. Eisenach, Vasiliy A. Naprimerov, Alexey Kuznetsov, Elena L. Lushnikova et al.
International Journal of Molecular Sciences
Electrospun Nanofibers in Biomedical Applications
article

Comparative Evaluation of Tissue and Systemic Responses to Electrospun Biodegradable Polymer and Polypropylene Implants Using hs-CRP and Immunohistochemical Markers

Igor A. Eisenach, Vasiliy A. Naprimerov, Alexey Kuznetsov, Elena L. Lushnikova, Galina A. Lapii, Anastasia O. Solovieva
article en

Abstract

The use of biodegradable polymers for the surgical reinforcement of musculofascial structures is of considerable practical interest. Research into the applicability of biopolymers should be conducted in comparison with polypropylene, a material used in surgery. Using highly sensitive C-reactive protein (hs-CRP) in blood and interleukin-6 (IL-6) and CD34 (an endothelial marker with angiogenic properties) in tissues, we analyzed the systemic and local tissue responses to polypropylene and biodegradable polymer implantation in 42 laboratory rats over a three-month period. The study confirmed good biocompatibility of both polymers. However, the systemic and tissue responses to the biopolymer, as measured by the studied markers, were significantly less pronounced compared to polypropylene. Persistently elevated levels of hs-CRP and CD34-positive cells in the biopolymer group at three months post-implantation were attributed to ongoing biotransformation processes. The mild inflammatory response following biopolymer implantation confirms not only its bioinert properties but also its potential for practical surgical applications. Elevated levels of hs-CRP and CD34-, as well as IL-6-positive cells in the polypropylene group, warrant further investigation of long-term responses to polypropylene as potential contributors to post-implantation complications. The hs-CRP level correlated with tissue markers IL-6 and CD34, suggesting its utility as a criterion for assessing postoperative adaptation to implanted synthetic materials.

International Journal of Molecular SciencesVol. 27(7)
Novosibirsk State Medical University (RU), Institute of Organic Synthesis (RU), Institute of Cytology and Genetics (RU), Ural Branch of the Russian Academy of Sciences (RU), Institute of Molecular Pathology and Pathomorphology (RU), Institute of Clinical and Experimental Lymphology (RU)
Siberian Branch, Russian Academy of Sciences
Openalex Percentile: Top 25%
Electrospun Nanofibers in Biomedical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.