Comparison of Three-Dimensional Multi-Echo in Steady-State Acquisition and Short-Tau Inversion Recovery Sequences in Brachial Plexus Magnetic Resonance Neurography

BACKGROUND AND PURPOSE: susceptibility and robust fat suppression. An alternative 3D acquisition is a multi-echo in steady-state acquisition (MENSA-NERVE) sequence that typically provides more robust vascular suppression, but poorer fat suppression due to its use of a water excitation pulse. MATERIALS AND METHODS: A total of 50 subjects (24 female, median age [range]: 34 years [14-73]) who underwent unilateral BP MRN at 3-Telsa where non-contrast STIR-FSE and MENSA-NERVE were sequentially acquired and retrospectively analyzed. Sequences were assessed by 2 radiologists for vascular suppression, fat suppression, and visualization of the BP nerve roots, trunks, and cords as well as of the suprascapular nerve and axillary nerve. Pooled measurements were analyzed using the Wilcoxon signed-rank test, and agreement proportion was used to assess inter-rater/inter-sequence diagnostic agreement. RESULTS: MENSA-NERVE outperformed STIR-FSE for vascular suppression (p<0.001). Fat suppression assessments favored STIR-FSE over MENSA-NERVE (p=0.05 to <0.001), with incomplete fat suppression obscuring nerve visualization in MENSA-NERVE primarily observed only at the lung apex. MENSA-NERVE provided superior visualization of the suprascapular and axillary nerves (p=0.004 to <0.001). Interrater agreement of visualized pathology was good to excellent (agreement=0.74-0.92) for both sequences. Inter-sequence agreement was also excellent (agreement=0.80-0.88). CONCLUSION: MENSA-NERVE provided superior vascular suppression and nerve conspicuity as compared to non-contrast STIR-FSE and with less robust fat suppression at the neck-shoulder junction and lung apex.

Authors

Institutions

Publication Details

Journal
American Journal of Neuroradiology
Published
2026-04-02
DOI
https://doi.org/10.3174/ajnr.a9328
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Three-Dimensional Multi-Echo in Steady-State Acquisition and Short-Tau Inversion Recovery Sequences in Brachial Plexus Magnetic Resonance Neurography

Philip G. Colucci, Darryl B. Sneag, Shu-Han Wang, Yan Wen et al.
American Journal of Neuroradiology
Advanced MRI Techniques and Applications
article

Comparison of Three-Dimensional Multi-Echo in Steady-State Acquisition and Short-Tau Inversion Recovery Sequences in Brachial Plexus Magnetic Resonance Neurography

Philip G. Colucci, Darryl B. Sneag, Shu-Han Wang, Yan Wen, Ek T Tan, Ji Lin, Maggie Fung
article en

Abstract

BACKGROUND AND PURPOSE: susceptibility and robust fat suppression. An alternative 3D acquisition is a multi-echo in steady-state acquisition (MENSA-NERVE) sequence that typically provides more robust vascular suppression, but poorer fat suppression due to its use of a water excitation pulse. MATERIALS AND METHODS: A total of 50 subjects (24 female, median age [range]: 34 years [14-73]) who underwent unilateral BP MRN at 3-Telsa where non-contrast STIR-FSE and MENSA-NERVE were sequentially acquired and retrospectively analyzed. Sequences were assessed by 2 radiologists for vascular suppression, fat suppression, and visualization of the BP nerve roots, trunks, and cords as well as of the suprascapular nerve and axillary nerve. Pooled measurements were analyzed using the Wilcoxon signed-rank test, and agreement proportion was used to assess inter-rater/inter-sequence diagnostic agreement. RESULTS: MENSA-NERVE outperformed STIR-FSE for vascular suppression (p<0.001). Fat suppression assessments favored STIR-FSE over MENSA-NERVE (p=0.05 to <0.001), with incomplete fat suppression obscuring nerve visualization in MENSA-NERVE primarily observed only at the lung apex. MENSA-NERVE provided superior visualization of the suprascapular and axillary nerves (p=0.004 to <0.001). Interrater agreement of visualized pathology was good to excellent (agreement=0.74-0.92) for both sequences. Inter-sequence agreement was also excellent (agreement=0.80-0.88). CONCLUSION: MENSA-NERVE provided superior vascular suppression and nerve conspicuity as compared to non-contrast STIR-FSE and with less robust fat suppression at the neck-shoulder junction and lung apex.

American Journal of Neuroradiology
Hospital for Special Surgery (US)
Openalex Percentile: Top 24%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of Three-Dimensional Multi-Echo in Steady-State Acquisition and Short-Tau Inversion Recovery Sequences in Brachial Plexus Magnetic Resonance Neurography — Philip G. Colucci, Darryl B. Sneag, et al. · American Journal of Neuroradiology (2026) | TGRS Research Map | TGRS