Accuracy of the cockcroft–gault equation in estimating glomerular filtration rate in normal pregnant ladies at different gestations

Background Pregnancy induces substantial renal physiological changes, including glomerular hyperfiltration and decreased serum creatinine concentrations. Creatinine-based estimation equations developed for nonpregnant populations may inaccurately reflect pregnancy-related hyperfiltration. This study evaluated the accuracy of Cockcroft–Gault-derived estimated glomerular filtration rate (eGFR) against measured creatinine clearance (CrCl) across pregnancy trimesters in women with normal kidney function. Patients and methods This cross-sectional study was conducted at Mansoura University Hospital and Ministry of Health hospitals in Egypt between May and October 2024. A total of 30 pregnant women (10 per trimester) with singleton pregnancies and no comorbidities were enrolled. Twenty-four-hour CrCl was compared with Cockcroft–Gault-derived eGFR. Statistical analyses included Paired t -tests, Wilcoxon signed-rank tests, and Bland–Altman analysis. Results The mean maternal age was 28.7 ± 6.41 years, with a mean BMI of 32.7 ± 5.07 kg/m 2 . Mean measured CrCl was 121 ± 12.6 ml/min, whereas mean eGFR was substantially higher at 212 ± 49.1 ml/min/1.73 m 2 . Significant overestimation was observed across all trimesters: first-trimester bias 73.8 ± 60.21 ml/min ( P =0.004), second-trimester bias 98.8 ± 58 ml/min ( P <0.001), and third-trimester bias 99.45 ± 43.1 ml/min ( P <0.001). Bland–Altman analysis demonstrated poor agreement with wide limits and proportional bias, particularly at higher GFR values. Conclusion The Cockcroft–Gault equation systematically overestimates GFR throughout pregnancy, with the magnitude of overestimation increasing from early to late gestation. Clinicians should exercise caution when using this equation in pregnant women. Twenty-four-hour CrCl measurement remains preferable for accurate assessment of renal function during pregnancy, particularly for medication dosing adjustments.

Authors

Institutions

Publication Details

Journal
Journal of The Egyptian Society of Nephrology and Transplantation
Published
2026-04-01
DOI
https://doi.org/10.4103/jesnt.jesnt_37_25
Primary Topic
Chronic Kidney Disease and Diabetes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of the cockcroft–gault equation in estimating glomerular filtration rate in normal pregnant ladies at different gestations

Rasha Samir Shemies, Ahmed Yahia Elmowafy, Mohamed Sobh, Walaa M.A. Soltan
Journal of The Egyptian Society of Nephrology and Transplantation
Chronic Kidney Disease and Diabetes
article

Accuracy of the cockcroft–gault equation in estimating glomerular filtration rate in normal pregnant ladies at different gestations

Rasha Samir Shemies, Ahmed Yahia Elmowafy, Mohamed Sobh, Walaa M.A. Soltan
article en

Abstract

Background Pregnancy induces substantial renal physiological changes, including glomerular hyperfiltration and decreased serum creatinine concentrations. Creatinine-based estimation equations developed for nonpregnant populations may inaccurately reflect pregnancy-related hyperfiltration. This study evaluated the accuracy of Cockcroft–Gault-derived estimated glomerular filtration rate (eGFR) against measured creatinine clearance (CrCl) across pregnancy trimesters in women with normal kidney function. Patients and methods This cross-sectional study was conducted at Mansoura University Hospital and Ministry of Health hospitals in Egypt between May and October 2024. A total of 30 pregnant women (10 per trimester) with singleton pregnancies and no comorbidities were enrolled. Twenty-four-hour CrCl was compared with Cockcroft–Gault-derived eGFR. Statistical analyses included Paired t -tests, Wilcoxon signed-rank tests, and Bland–Altman analysis. Results The mean maternal age was 28.7 ± 6.41 years, with a mean BMI of 32.7 ± 5.07 kg/m 2 . Mean measured CrCl was 121 ± 12.6 ml/min, whereas mean eGFR was substantially higher at 212 ± 49.1 ml/min/1.73 m 2 . Significant overestimation was observed across all trimesters: first-trimester bias 73.8 ± 60.21 ml/min ( P =0.004), second-trimester bias 98.8 ± 58 ml/min ( P <0.001), and third-trimester bias 99.45 ± 43.1 ml/min ( P <0.001). Bland–Altman analysis demonstrated poor agreement with wide limits and proportional bias, particularly at higher GFR values. Conclusion The Cockcroft–Gault equation systematically overestimates GFR throughout pregnancy, with the magnitude of overestimation increasing from early to late gestation. Clinicians should exercise caution when using this equation in pregnant women. Twenty-four-hour CrCl measurement remains preferable for accurate assessment of renal function during pregnancy, particularly for medication dosing adjustments.

Journal of The Egyptian Society of Nephrology and TransplantationVol. 26(2)
Mansoura University (EG)
Good health and well-being
Openalex Percentile: Top 5%
Chronic Kidney Disease and Diabetes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.