Implantable Cardioverter-Defibrillator Therapy and Implantable Cardioverter-Defibrillator Complications in Idiopathic Ventricular Fibrillation Patients

BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy is used to prevent sudden cardiac death (SCD) in patients who experienced idiopathic ventricular fibrillation (IVF). Only certain patients with IVF develop recurrence of ventricular arrhythmia (VA). However, all patients with IVF are exposed to the risk of complications. Transvenous ICD (TV-ICD) carries a significant complication risk. The subcutaneous ICD (S-ICD) may offer advantages in this young population. OBJECTIVES: The aim of this study was to analyze ICD therapy in patients with IVF and to assess complications of ICD therapy, comparing S-ICD and TV-ICD. METHODS: Patients were included from the Dutch IVF Registry. First, the occurrence of appropriate ICD therapy (shock/anti-tachycardia pacing) was analyzed. A subgroup was then defined of patients with ICD implantation between 2010 and 2024 to assess inappropriate ICD therapy and other device-related complications. Next, a comparison was made between S-ICD and TV-ICD. RESULTS: Of 415 included patients with IVF, 132 (32%) experienced recurrent VA requiring ICD therapy; subanalysis included 261 patients. There were no significant differences in inappropriate ICD therapy (S-ICD 13% vs TV-ICD 13%; P = 0.976) between S-ICD and TV-ICD. TV-ICD patients had more lead complications compared with S-ICD patients (S-ICD 2% vs TV-ICD 13%; P < 0.001). For the other device-related complications, there were no significant differences between S-ICD and TV-ICD. These results were consistent when corrected for different follow-up duration and age at index event. CONCLUSIONS: VA recurrence occurs frequently, affecting nearly one-third of patients with IVF. Comparing S-ICD and TV-ICD, there were no significant differences in inappropriate ICD therapy. Lead complications were more prevalent with TV-ICD compared with S-ICD.

Authors

Institutions

Publication Details

Journal
JACC. Clinical electrophysiology
Published
2026-04-01
DOI
https://doi.org/10.1016/j.jacep.2026.02.026
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implantable Cardioverter-Defibrillator Therapy and Implantable Cardioverter-Defibrillator Complications in Idiopathic Ventricular Fibrillation Patients

Wiert F. Hoeksema, Pieter G. Postema, Gijsbert F.L. Kapel, Mathias Meine et al.
JACC. Clinical electrophysiology
Cardiac pacing and defibrillation studies
article

Implantable Cardioverter-Defibrillator Therapy and Implantable Cardioverter-Defibrillator Complications in Idiopathic Ventricular Fibrillation Patients

Wiert F. Hoeksema, Pieter G. Postema, Gijsbert F.L. Kapel, Mathias Meine, Reinder Evertz, Pepijn van der Voort, Rutger J. Hassink, Bart A. Mulder, Marianne Bootsma, Rozan Roodenburg, Sing Chien Yap, Paul G.A. Volders, Lisa M. Verheul, Jippe C. Balt, Marco Alings, Arthur A.M. Wilde
article en

Abstract

BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy is used to prevent sudden cardiac death (SCD) in patients who experienced idiopathic ventricular fibrillation (IVF). Only certain patients with IVF develop recurrence of ventricular arrhythmia (VA). However, all patients with IVF are exposed to the risk of complications. Transvenous ICD (TV-ICD) carries a significant complication risk. The subcutaneous ICD (S-ICD) may offer advantages in this young population. OBJECTIVES: The aim of this study was to analyze ICD therapy in patients with IVF and to assess complications of ICD therapy, comparing S-ICD and TV-ICD. METHODS: Patients were included from the Dutch IVF Registry. First, the occurrence of appropriate ICD therapy (shock/anti-tachycardia pacing) was analyzed. A subgroup was then defined of patients with ICD implantation between 2010 and 2024 to assess inappropriate ICD therapy and other device-related complications. Next, a comparison was made between S-ICD and TV-ICD. RESULTS: Of 415 included patients with IVF, 132 (32%) experienced recurrent VA requiring ICD therapy; subanalysis included 261 patients. There were no significant differences in inappropriate ICD therapy (S-ICD 13% vs TV-ICD 13%; P = 0.976) between S-ICD and TV-ICD. TV-ICD patients had more lead complications compared with S-ICD patients (S-ICD 2% vs TV-ICD 13%; P < 0.001). For the other device-related complications, there were no significant differences between S-ICD and TV-ICD. These results were consistent when corrected for different follow-up duration and age at index event. CONCLUSIONS: VA recurrence occurs frequently, affecting nearly one-third of patients with IVF. Comparing S-ICD and TV-ICD, there were no significant differences in inappropriate ICD therapy. Lead complications were more prevalent with TV-ICD compared with S-ICD.

JACC. Clinical electrophysiology
University Medical Center Groningen (NL), Radboud University Nijmegen (NL), Leiden University Medical Center (NL), Catharina Ziekenhuis (NL), Medisch Spectrum Twente (NL), Erasmus MC (NL), Radboud University Medical Center (NL), University Medical Center Utrecht (NL), Maastricht University (NL), St. Antonius Ziekenhuis (NL), Amphia Ziekenhuis (NL), Amsterdam University Medical Centers (NL), Altrecht GGZ (NL)
Hartstichting
Good health and well-being
Openalex Percentile: Top 32%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.