Outdoor daytime passive radiative cooling by transparent skylights in a Nordic climate

• Outdoor-validated passive cooling with Cleartran ZnS (CG) + 3 M solar-control film. • Sky-directed daytime longwave heat flux Q CG via the Cleartran path. • TiO 2 –SiO 2 nanparticles (NPs) on CG increases the passive cooling flux. • NPs improve cooling with air in skylight: 38.5 to 54.0 W/m 2 , CO 2 45.8 to 63.0 W/m 2 . • Using air/NH 3 (2:1) peaks at ≈ 66 W/m 2 ; NPs gain is modest (+3.6%). Rising cooling demands motivate passive alternatives to air conditioning. This study evaluates a transparent skylight window for daytime passive radiative cooling (PRC) under outdoor summer conditions in Turku, Finland. A heated box held a two-sided skylight window (0.72 m × 0.225 m × 0.08 m). The skylight consists of standard window glass (SWG) and circular Cleartran® ZnS inserts (CG). The inserts (Ø 0.10 m) were positioned diagonally in the lower window facing indoors and in the upper window facing the sky. The upper SWG carried a 3 M solar-control thin film (TF, ∼65% solar reflectance). The sky facing CG surfaces were covered with dispersed TiO 2 –SiO 2 nanoparticles (NPs, ≈30% areal coverage). The skylight gas volume contained air, CO 2 , or air/NH 3 (2:1). A pyrgeometer provided local weather data as long-wave (LW) irradiance (L↓). Overall performance is reported as the sky-directed net LW radiative heat flux, split into Q CG (CG insert region, with and without NPs) and Q SWG+TF (SWG region covered by TF). The SWG + TF surface is effectively opaque in the LW range (4–14 µm). On a clear summer day (14:00–20:00), Q CG increases 38.5 → 54.0 W/m 2 for air (+40.3% with NPs), 45.8 → 63.0 W/m 2 for CO 2 (+37.6%), and 63.5 → 66.0 W/m 2 for air/NH 3 (+3.6%). NPs increase thermal radiation via CG. Because NH 3 strongly participates in the 8–14 µm atmospheric window, the additional benefit from NPs is smaller, even though the total radiative flux is highest.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2026-04-03
DOI
https://doi.org/10.1016/j.enbuild.2026.117406
Primary Topic
Thermal Radiation and Cooling Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Outdoor daytime passive radiative cooling by transparent skylights in a Nordic climate

Gopalakrishna Gangisetty, Kushagra Uniyal, Ron Zevenhoven
Energy and Buildings
Thermal Radiation and Cooling Technologies
article

Outdoor daytime passive radiative cooling by transparent skylights in a Nordic climate

Gopalakrishna Gangisetty, Kushagra Uniyal, Ron Zevenhoven
article en

Abstract

• Outdoor-validated passive cooling with Cleartran ZnS (CG) + 3 M solar-control film. • Sky-directed daytime longwave heat flux Q CG via the Cleartran path. • TiO 2 –SiO 2 nanparticles (NPs) on CG increases the passive cooling flux. • NPs improve cooling with air in skylight: 38.5 to 54.0 W/m 2 , CO 2 45.8 to 63.0 W/m 2 . • Using air/NH 3 (2:1) peaks at ≈ 66 W/m 2 ; NPs gain is modest (+3.6%). Rising cooling demands motivate passive alternatives to air conditioning. This study evaluates a transparent skylight window for daytime passive radiative cooling (PRC) under outdoor summer conditions in Turku, Finland. A heated box held a two-sided skylight window (0.72 m × 0.225 m × 0.08 m). The skylight consists of standard window glass (SWG) and circular Cleartran® ZnS inserts (CG). The inserts (Ø 0.10 m) were positioned diagonally in the lower window facing indoors and in the upper window facing the sky. The upper SWG carried a 3 M solar-control thin film (TF, ∼65% solar reflectance). The sky facing CG surfaces were covered with dispersed TiO 2 –SiO 2 nanoparticles (NPs, ≈30% areal coverage). The skylight gas volume contained air, CO 2 , or air/NH 3 (2:1). A pyrgeometer provided local weather data as long-wave (LW) irradiance (L↓). Overall performance is reported as the sky-directed net LW radiative heat flux, split into Q CG (CG insert region, with and without NPs) and Q SWG+TF (SWG region covered by TF). The SWG + TF surface is effectively opaque in the LW range (4–14 µm). On a clear summer day (14:00–20:00), Q CG increases 38.5 → 54.0 W/m 2 for air (+40.3% with NPs), 45.8 → 63.0 W/m 2 for CO 2 (+37.6%), and 63.5 → 66.0 W/m 2 for air/NH 3 (+3.6%). NPs increase thermal radiation via CG. Because NH 3 strongly participates in the 8–14 µm atmospheric window, the additional benefit from NPs is smaller, even though the total radiative flux is highest.

Energy and BuildingsVol. 360
Åbo Akademi University (FI)
Åbo Akademi, Svenska Litteratursällskapet i Finland
Climate action
Openalex Percentile: Top 27%
Thermal Radiation and Cooling Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Outdoor daytime passive radiative cooling by transparent skylights in a Nordic climate — Gopalakrishna Gangisetty, Kushagra Uniyal, et al. · Energy and Buildings (2026) | TGRS Research Map | TGRS