Effects of temperature and pH on the GSM and 2-MIB degradation by UV-LEDs/HClO advanced oxidation

While Ozone-based processes have demonstrated good performance treating 2-methylisoborneol (2-MIB) and geosmin (GSM) in drinking water, their reaction efficiency decreases at low temperatures. To overcome this limitation, UV-based advanced oxidation processes (AOPs) have emerged as promising alternatives. This study proposes an innovative UV-LED/HClO AOP system and systematically evaluates its removal performance for GSM and 2-MIB under varying temperature and pH conditions. results indicated that the degradation processes of 2-MIB and GSM followed first-order kinetic models ( R 2 > 0.72, p < 0.001). Reaction rates significantly increased at 20°C and pH 6 for both odorous compounds ( k 2-MIB = 1.86 × 10 -3 cm 2 mJ -1 , k GSM = 2.38 × 10 -3 cm 2 mJ -1 ), compared to those at 4°C. The apparent rate constants increased by approximately 20 to 30% when temperature rose from 4 to 20 °C, which is smaller than the 30–50% temperature-induced deterioration reported for ozone-based processes in previous studies. In coagulated water collected from an operating treatment plant, good linear relationships between fluence and degradation were maintained ( R 2 = 0.83 to 0.94, p < 0.001). Overall, the UV-LEDs/HClO AOP exhibited reduced sensitivity to low temperatures, highlighting its potential as an effective odor-control strategy for drinking water treatment in cold environments. ● UV/HClO-AOPs were applied for GSM and 2-MIB using 280 nm UV-LED. ● Effects of water temperature on the degradation were examined. ● Degradation was compared at different target concentrations, pH, and HClO levels. ● Efficiencies declined at 4°C compared to 20°C but in a milder manner than ozonation. ● Lower efficiencies in samples from a real plant, showing challenges for the future.

Authors

Institutions

Publication Details

Journal
Desalination and Water Treatment
Published
2026-04-01
DOI
https://doi.org/10.1016/j.dwt.2026.101746
Primary Topic
Wastewater Treatment and Nitrogen Removal
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of temperature and pH on the GSM and 2-MIB degradation by UV-LEDs/HClO advanced oxidation

Hazuki Tsuruno, Jun Kobashi, Jin Li, Kumiko Oguma et al.
Desalination and Water Treatment
Wastewater Treatment and Nitrogen Removal
article

Effects of temperature and pH on the GSM and 2-MIB degradation by UV-LEDs/HClO advanced oxidation

Hazuki Tsuruno, Jun Kobashi, Jin Li, Kumiko Oguma, Kenichi Yoshizawa
article en

Abstract

While Ozone-based processes have demonstrated good performance treating 2-methylisoborneol (2-MIB) and geosmin (GSM) in drinking water, their reaction efficiency decreases at low temperatures. To overcome this limitation, UV-based advanced oxidation processes (AOPs) have emerged as promising alternatives. This study proposes an innovative UV-LED/HClO AOP system and systematically evaluates its removal performance for GSM and 2-MIB under varying temperature and pH conditions. results indicated that the degradation processes of 2-MIB and GSM followed first-order kinetic models ( R 2 > 0.72, p < 0.001). Reaction rates significantly increased at 20°C and pH 6 for both odorous compounds ( k 2-MIB = 1.86 × 10 -3 cm 2 mJ -1 , k GSM = 2.38 × 10 -3 cm 2 mJ -1 ), compared to those at 4°C. The apparent rate constants increased by approximately 20 to 30% when temperature rose from 4 to 20 °C, which is smaller than the 30–50% temperature-induced deterioration reported for ozone-based processes in previous studies. In coagulated water collected from an operating treatment plant, good linear relationships between fluence and degradation were maintained ( R 2 = 0.83 to 0.94, p < 0.001). Overall, the UV-LEDs/HClO AOP exhibited reduced sensitivity to low temperatures, highlighting its potential as an effective odor-control strategy for drinking water treatment in cold environments. ● UV/HClO-AOPs were applied for GSM and 2-MIB using 280 nm UV-LED. ● Effects of water temperature on the degradation were examined. ● Degradation was compared at different target concentrations, pH, and HClO levels. ● Efficiencies declined at 4°C compared to 20°C but in a milder manner than ozonation. ● Lower efficiencies in samples from a real plant, showing challenges for the future.

Desalination and Water TreatmentVol. 326
Tokyo Metropolitan Government (JP), The University of Tokyo (JP)
Tokyo Metropolitan Government, Japan Society for the Promotion of Science
Clean water and sanitation
Openalex Percentile: Top 26%
Wastewater Treatment and Nitrogen Removal
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.