Association between aortic arch atheroma and periprocedural stroke following transcatheter aortic valve implantation

Abstract Background and Aims This study examined the impact of aortic arch atheroma severity on the risk of periprocedural stroke following transcatheter aortic valve implantation (TAVI). Methods and results We retrospectively evaluated contrast-enhanced computed tomography data of patients who underwent transfemoral-TAVI from May 2016 to March 2024. Aortic arch atheroma was classified into none/mild [maximum plaque thickness (MPT) <3 mm], moderate (MPT 3–5 mm), severe (MPT >5 mm without shaggy morphology), and shaggy (MPT >5 mm with shaggy morphology). The primary outcome measure was periprocedural (30-day) ischaemic stroke following TAVI. Of the 1971 eligible patients, 65 (3.3%) experienced periprocedural ischaemic stroke. Compared with none/mild atheroma, moderate atheroma [adjusted odds ratio (aOR) 2.93; 95% confidence interval (CI), 1.63–5.28; P < .001] and shaggy atheroma (aOR 14.58; 95% CI, 6.67–31.87; P < .001) were independently associated with increased risk of periprocedural stroke. Severe atheroma exhibited a similar trend, albeit without statistical significance (aOR 2.81; 95% CI, 0.92–8.61; P = .07). In the balloon-expandable transcatheter heart valve (BE-THV) cohort, stroke incidence was significantly increased only in the shaggy group (1.1% vs. 2.8% vs. 1.4% vs. 11.9%, P < .001); however, stroke incidence across the atheroma severity groups in the self-expandable THV (SE-THV) cohort demonstrated a stepwise increase (2.8% vs. 8.2% vs. 13.6% vs. 33.3%, P < .001). Conclusions Aortic arch atheroma severity was associated with an increased risk of periprocedural stroke following transfemoral-TAVI, with the impact being more pronounced in patients treated with SE-THV than in those treated with BE-THV.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Valvular and Structural Heart Disease
Published
2026-04-01
DOI
https://doi.org/10.1093/ehjvshd/xwag024
Citations
1
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
20.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association between aortic arch atheroma and periprocedural stroke following transcatheter aortic valve implantation

Yu Yoshino, Toru Morofuji, Akihiro Isotani, Shinichi Kakumoto et al.
1 citations
European Heart Journal - Valvular and Structural Heart Disease
Aortic Disease and Treatment Approaches
20.77
article

Association between aortic arch atheroma and periprocedural stroke following transcatheter aortic valve implantation

Yu Yoshino, Toru Morofuji, Akihiro Isotani, Shinichi Kakumoto, Hayashi Wakugawa, Yasuo Tsuru, Norihisa Miyawaki, Satoru Yoshida, Tomohiro Suenaga, Euihong Ko, Keisuke Miyamoto, Kenji Nakano, Kenichi Ishizu, Shinichi Shirai, Kenji Ando, Katsunori Miyahara, Nobuhisa Ohno, Masaomi Hayashi
article en
1 citations

Abstract

Abstract Background and Aims This study examined the impact of aortic arch atheroma severity on the risk of periprocedural stroke following transcatheter aortic valve implantation (TAVI). Methods and results We retrospectively evaluated contrast-enhanced computed tomography data of patients who underwent transfemoral-TAVI from May 2016 to March 2024. Aortic arch atheroma was classified into none/mild [maximum plaque thickness (MPT) <3 mm], moderate (MPT 3–5 mm), severe (MPT >5 mm without shaggy morphology), and shaggy (MPT >5 mm with shaggy morphology). The primary outcome measure was periprocedural (30-day) ischaemic stroke following TAVI. Of the 1971 eligible patients, 65 (3.3%) experienced periprocedural ischaemic stroke. Compared with none/mild atheroma, moderate atheroma [adjusted odds ratio (aOR) 2.93; 95% confidence interval (CI), 1.63–5.28; P < .001] and shaggy atheroma (aOR 14.58; 95% CI, 6.67–31.87; P < .001) were independently associated with increased risk of periprocedural stroke. Severe atheroma exhibited a similar trend, albeit without statistical significance (aOR 2.81; 95% CI, 0.92–8.61; P = .07). In the balloon-expandable transcatheter heart valve (BE-THV) cohort, stroke incidence was significantly increased only in the shaggy group (1.1% vs. 2.8% vs. 1.4% vs. 11.9%, P < .001); however, stroke incidence across the atheroma severity groups in the self-expandable THV (SE-THV) cohort demonstrated a stepwise increase (2.8% vs. 8.2% vs. 13.6% vs. 33.3%, P < .001). Conclusions Aortic arch atheroma severity was associated with an increased risk of periprocedural stroke following transfemoral-TAVI, with the impact being more pronounced in patients treated with SE-THV than in those treated with BE-THV.

European Heart Journal - Valvular and Structural Heart DiseaseVol. 2(2)
Kokura Memorial Hospital (JP)
Good health and well-being
Openalex Percentile: Top 1%
Aortic Disease and Treatment Approaches
20.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.