Continuous Hemodynamic Monitoring During Transcatheter Tricuspid Valve Repair: Insights From Pulse Contour-based Assessment

OBJECTIVES: This exploratory pilot study was designed to evaluate the effectiveness of pulse contour analysis (PCA) for real-time hemodynamic monitoring in patients undergoing transcatheter edge-to-edge tricuspid valve repair (T-TEER). Additionally, it examined whether continuous PCA monitoring can identify indicators of procedural success and improve perioperative management. DESIGN: Prospective, hypothesis-generating pilot, single-center study. SETTING: Single tertiary care university hospital. PARTICIPANTS: A total of 12 patients undergoing T-TEER. INTERVENTIONS: Real-time PCA was used throughout the intervention period, from preoperative assessment up to 4 hours postprocedure, to monitor hemodynamic parameters (cardiac output [CO], cardiac index [CI], stroke volume, stroke volume variation, and blood pressure). MEASUREMENTS AND MAIN RESULTS: At 4 hours after T-TEER, CO-PCA had increased by 30% (p = 0.0124), accompanied by a 0.68-L/min/m² rise in CI (p = 0.008). T-TEER also resulted in a persistent reduction in stroke volume variation-PCA, with a sustained 3% decrease after the intervention (p = 0.009). Implantation of the first device triggered a notable peri-interventional increase in systolic arterial pressure of 17 mmHg (p = 0.026). In addition, the right atrial v-wave decreased by 8 mmHg (p = 0.034). No meaningful changes in central venous oxygen saturation or central venous pressure were detected during or following the procedure (p = 0.73 and p = 0.27, respectively). CONCLUSIONS: This study demonstrated that PCA using FloTrack monitoring can provide valuable continuous hemodynamic information and characterize acute hemodynamic responses to T-TEER. PCA detected meaningful hemodynamic improvements during T-TEER, characterized by increased CO, enhanced CI, and more stable preload conditions.

Authors

Institutions

Publication Details

Journal
Journal of Cardiothoracic and Vascular Anesthesia
Published
2026-04-01
DOI
https://doi.org/10.1053/j.jvca.2026.03.056
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Hemodynamic Monitoring During Transcatheter Tricuspid Valve Repair: Insights From Pulse Contour-based Assessment

Florian Uhle, Christoph Lichtenstern, Sandra Uhle, Mathias H. Konstandin et al.
Journal of Cardiothoracic and Vascular Anesthesia
Hemodynamic Monitoring and Therapy
article

Continuous Hemodynamic Monitoring During Transcatheter Tricuspid Valve Repair: Insights From Pulse Contour-based Assessment

Florian Uhle, Christoph Lichtenstern, Sandra Uhle, Mathias H. Konstandin, B. Alt-Epping, Matthias Eden, Sarah Dehne, Adrian Stephan, M. A. Weigand, M. Dietrich, Norbert Frey
article en

Abstract

OBJECTIVES: This exploratory pilot study was designed to evaluate the effectiveness of pulse contour analysis (PCA) for real-time hemodynamic monitoring in patients undergoing transcatheter edge-to-edge tricuspid valve repair (T-TEER). Additionally, it examined whether continuous PCA monitoring can identify indicators of procedural success and improve perioperative management. DESIGN: Prospective, hypothesis-generating pilot, single-center study. SETTING: Single tertiary care university hospital. PARTICIPANTS: A total of 12 patients undergoing T-TEER. INTERVENTIONS: Real-time PCA was used throughout the intervention period, from preoperative assessment up to 4 hours postprocedure, to monitor hemodynamic parameters (cardiac output [CO], cardiac index [CI], stroke volume, stroke volume variation, and blood pressure). MEASUREMENTS AND MAIN RESULTS: At 4 hours after T-TEER, CO-PCA had increased by 30% (p = 0.0124), accompanied by a 0.68-L/min/m² rise in CI (p = 0.008). T-TEER also resulted in a persistent reduction in stroke volume variation-PCA, with a sustained 3% decrease after the intervention (p = 0.009). Implantation of the first device triggered a notable peri-interventional increase in systolic arterial pressure of 17 mmHg (p = 0.026). In addition, the right atrial v-wave decreased by 8 mmHg (p = 0.034). No meaningful changes in central venous oxygen saturation or central venous pressure were detected during or following the procedure (p = 0.73 and p = 0.27, respectively). CONCLUSIONS: This study demonstrated that PCA using FloTrack monitoring can provide valuable continuous hemodynamic information and characterize acute hemodynamic responses to T-TEER. PCA detected meaningful hemodynamic improvements during T-TEER, characterized by increased CO, enhanced CI, and more stable preload conditions.

Journal of Cardiothoracic and Vascular Anesthesia
Heidelberg University (DE), University Hospital Heidelberg (DE)
Universität Heidelberg
Openalex Percentile: Top 36%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.