Research on anomaly data augmentation and health status evaluation methods for filter field circuit breakers

Circuit breakers in converter station filter fields are critical protection and control components, and their operating condition directly affects the safety and stability of power transmission systems. In practical condition assessment tasks, field operational data are characterized by a severe class imbalance, where normal samples dominate and fault samples are extremely scarce, significantly degrading model accuracy and robustness. To address this challenge, an anomaly data augmentation approach based on a Conditional Wasserstein Generative Adversarial Network with Gradient Penalty (cWGAN-GP) is proposed. Multidimensional key features, including closing time and auxiliary switch operation time, are utilized. A small set of anomaly seed samples is first constructed using normal operation data combined with expert knowledge and manufacturer-defined thresholds. By introducing conditional constraints, the cWGAN-GP effectively learns the feature distribution of fault samples and generates high-quality synthetic data, thereby alleviating the imbalance problem. Furthermore, a Probabilistic Neural Network (PNN) optimized by the Dung Beetle Optimizer (DBO) is developed for circuit breaker health status identification. The DBO algorithm adaptively optimizes the key parameters of the PNN, improving classification performance. Experimental results demonstrate that the proposed framework achieves a macro F1-score of 88.21%, significantly outperforming benchmark models including Random Forest, ECOC-SVM, and XGBoost. The proposed method provides an effective solution to fault sample scarcity and offers a practical reference for intelligent condition assessment and operation and maintenance of power equipment.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2026-04-01
DOI
https://doi.org/10.1063/5.0322970
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on anomaly data augmentation and health status evaluation methods for filter field circuit breakers

Fenglong Ma, Hui Ni, Liyun Dai, Yousu Qin et al.
AIP Advances
Power Transformer Diagnostics and Insulation
article

Research on anomaly data augmentation and health status evaluation methods for filter field circuit breakers

Fenglong Ma, Hui Ni, Liyun Dai, Yousu Qin, Zhihui Huang, Jiaying Yu, Yongxing Wang
article en

Abstract

Circuit breakers in converter station filter fields are critical protection and control components, and their operating condition directly affects the safety and stability of power transmission systems. In practical condition assessment tasks, field operational data are characterized by a severe class imbalance, where normal samples dominate and fault samples are extremely scarce, significantly degrading model accuracy and robustness. To address this challenge, an anomaly data augmentation approach based on a Conditional Wasserstein Generative Adversarial Network with Gradient Penalty (cWGAN-GP) is proposed. Multidimensional key features, including closing time and auxiliary switch operation time, are utilized. A small set of anomaly seed samples is first constructed using normal operation data combined with expert knowledge and manufacturer-defined thresholds. By introducing conditional constraints, the cWGAN-GP effectively learns the feature distribution of fault samples and generates high-quality synthetic data, thereby alleviating the imbalance problem. Furthermore, a Probabilistic Neural Network (PNN) optimized by the Dung Beetle Optimizer (DBO) is developed for circuit breaker health status identification. The DBO algorithm adaptively optimizes the key parameters of the PNN, improving classification performance. Experimental results demonstrate that the proposed framework achieves a macro F1-score of 88.21%, significantly outperforming benchmark models including Random Forest, ECOC-SVM, and XGBoost. The proposed method provides an effective solution to fault sample scarcity and offers a practical reference for intelligent condition assessment and operation and maintenance of power equipment.

AIP AdvancesVol. 16(4)
Electric Power Research Institute (US), Dalian University of Technology (CN), Dalian University (CN), Ningxia Water Conservancy (CN)
Openalex Percentile: Top 34%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.