Biomechanical Comparison of All-Suture Anchors Versus Interference Screws for Femoral Fixation in Pediatric MPFL Reconstruction

Background: Pediatric patellofemoral instability is common, and medial patellofemoral ligament (MPFL) reconstruction is a highly effective treatment option. Femoral graft fixation methods include suture anchors (SAs) and interference screws (ISs), although comparative biomechanical studies in pediatric bone are lacking. Purpose: To compare the biomechanical properties of SA versus IS femoral graft fixation in pediatric MPFL reconstruction. Study Design: Controlled laboratory study. Methods: Ten fresh-frozen pediatric knees underwent femoral MPFL graft fixation using SA and IS (mean age, 9.5 years; range, 8-10 years). Posterior tibialis tendon allograft was used in both groups. For the IS group, 8-mm tunnels were drilled and 8 × 25-mm biocomposite IS was used for graft fixation. For the SA group, a 1.8-mm knotless all-suture SA was placed and secured to the graft. Specimens were loaded onto an Instron 5944 and subjected to cyclic preconditioning, followed by an ultimate failure load at 6 mm/s. The load displacement curve was then used to calculate stiffness (N/mm). Data were analyzed using repeated-measures analysis of variance to account for multiple measurements on the same specimens. Results: = .009). All but 1 IS reconstruction failed by graft pullout from the femoral tunnel, whereas all 10 SA reconstructions failed by anchor pullout. Conclusion: IS offers significantly higher ultimate failure load and stiffness values compared to SA femoral MPFL graft fixation in human pediatric knees. Mean ultimate failure load values for femoral MPFL fixation in pediatric bone may be lower than in adult bone, based on comparative adult studies. These results provide initial biomechanical data comparing 2 commonly used femoral fixation methods in skeletally immature patients. Clinical Relevance: This study characterized the biomechanical strength of SA and IS femoral MPFL fixation in pediatric bone, revealing differences in ultimate failure load and stiffness between constructs and compared to adult bone. While SA may pose less risk for growth alteration from physeal injury in younger patients, greater "time-zero" MPFL fixation strength with IS may allow for accelerated rehabilitation and earlier return to sport, which is a key patient and family satisfaction variable. In some circumstances, SA fixation may be preferred due to physeal proximity, and postoperative therapy regimens may be modified to account for lower fixation strength. These findings can help surgeons optimize implant selection, tailor rehabilitation protocols, and minimize the risk of graft failure in skeletally immature patients.

Authors

Institutions

Publication Details

Journal
Orthopaedic Journal of Sports Medicine
Published
2026-04-01
DOI
https://doi.org/10.1177/23259671261428088
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Comparison of All-Suture Anchors Versus Interference Screws for Femoral Fixation in Pediatric MPFL Reconstruction

Nicole S. Pham, Amin Alayleh, Calvin K. Chan, Ian Hollyer et al.
Orthopaedic Journal of Sports Medicine
Lower Extremity Biomechanics and Pathologies
article

Biomechanical Comparison of All-Suture Anchors Versus Interference Screws for Femoral Fixation in Pediatric MPFL Reconstruction

Nicole S. Pham, Amin Alayleh, Calvin K. Chan, Ian Hollyer, Matthew R. Schmitz, Kelly McFarlane, Nneoma Duru, Wills Baird, Theodore Ganley, Henry B. Ellis, Marc Tompkins, Kevin G. Shea, Austin Stoner, Yi-Meng Yen
article en

Abstract

Background: Pediatric patellofemoral instability is common, and medial patellofemoral ligament (MPFL) reconstruction is a highly effective treatment option. Femoral graft fixation methods include suture anchors (SAs) and interference screws (ISs), although comparative biomechanical studies in pediatric bone are lacking. Purpose: To compare the biomechanical properties of SA versus IS femoral graft fixation in pediatric MPFL reconstruction. Study Design: Controlled laboratory study. Methods: Ten fresh-frozen pediatric knees underwent femoral MPFL graft fixation using SA and IS (mean age, 9.5 years; range, 8-10 years). Posterior tibialis tendon allograft was used in both groups. For the IS group, 8-mm tunnels were drilled and 8 × 25-mm biocomposite IS was used for graft fixation. For the SA group, a 1.8-mm knotless all-suture SA was placed and secured to the graft. Specimens were loaded onto an Instron 5944 and subjected to cyclic preconditioning, followed by an ultimate failure load at 6 mm/s. The load displacement curve was then used to calculate stiffness (N/mm). Data were analyzed using repeated-measures analysis of variance to account for multiple measurements on the same specimens. Results: = .009). All but 1 IS reconstruction failed by graft pullout from the femoral tunnel, whereas all 10 SA reconstructions failed by anchor pullout. Conclusion: IS offers significantly higher ultimate failure load and stiffness values compared to SA femoral MPFL graft fixation in human pediatric knees. Mean ultimate failure load values for femoral MPFL fixation in pediatric bone may be lower than in adult bone, based on comparative adult studies. These results provide initial biomechanical data comparing 2 commonly used femoral fixation methods in skeletally immature patients. Clinical Relevance: This study characterized the biomechanical strength of SA and IS femoral MPFL fixation in pediatric bone, revealing differences in ultimate failure load and stiffness between constructs and compared to adult bone. While SA may pose less risk for growth alteration from physeal injury in younger patients, greater "time-zero" MPFL fixation strength with IS may allow for accelerated rehabilitation and earlier return to sport, which is a key patient and family satisfaction variable. In some circumstances, SA fixation may be preferred due to physeal proximity, and postoperative therapy regimens may be modified to account for lower fixation strength. These findings can help surgeons optimize implant selection, tailor rehabilitation protocols, and minimize the risk of graft failure in skeletally immature patients.

Orthopaedic Journal of Sports MedicineVol. 14(4)
Boston Children's Hospital (US), University of Minnesota (US), Children's Hospital of Philadelphia (US), University of California, San Francisco (US), Texas Scottish Rite Hospital for Children (US), Rady Children's Hospital-San Diego (US), Stanford University (US)
Openalex Percentile: Top 35%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.