A multimodal multi-scale transformer for virtual pretreatment patient-specific QA of SBRT using portal-dosimetry fluence maps

We developed a transformer-based multimodal neural network to predict the gamma passing rate (GPR) in stereotactic body radiation therapy (SBRT) patient-specific quality assurance. Using 1265 SBRT beams from two institutions, the model incorporated portal dose prediction fluence maps with beam complexity descriptors such as modulation complexity score and monitor units. A multi-scale visual-textual transformer, integrating a ViT encoder and feedforward network through a fusion head, was compared with state-of-the-art CNNs across nine gamma criteria. Our approach consistently achieved the lowest root mean squared error (RMSE) and mean absolute error (MAE), with values ranging from 0.785% to 4.258% and 0.418% to 3.197%, respectively, and ablation studies highlighted the necessity of multimodal fusion and multi-scale design. These results demonstrate superior predictive accuracy and generalizability, underscoring the potential of transformer-based multimodal learning to enhance treatment optimization and clinical QA efficiency.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-01
DOI
https://doi.org/10.1038/s41598-026-46687-4
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A multimodal multi-scale transformer for virtual pretreatment patient-specific QA of SBRT using portal-dosimetry fluence maps

Xiao-Suo He, Hong-Qiang You, Jia-Jun Zheng
Scientific Reports
Advanced Radiotherapy Techniques
article

A multimodal multi-scale transformer for virtual pretreatment patient-specific QA of SBRT using portal-dosimetry fluence maps

Xiao-Suo He, Hong-Qiang You, Jia-Jun Zheng
article en

Abstract

We developed a transformer-based multimodal neural network to predict the gamma passing rate (GPR) in stereotactic body radiation therapy (SBRT) patient-specific quality assurance. Using 1265 SBRT beams from two institutions, the model incorporated portal dose prediction fluence maps with beam complexity descriptors such as modulation complexity score and monitor units. A multi-scale visual-textual transformer, integrating a ViT encoder and feedforward network through a fusion head, was compared with state-of-the-art CNNs across nine gamma criteria. Our approach consistently achieved the lowest root mean squared error (RMSE) and mean absolute error (MAE), with values ranging from 0.785% to 4.258% and 0.418% to 3.197%, respectively, and ablation studies highlighted the necessity of multimodal fusion and multi-scale design. These results demonstrate superior predictive accuracy and generalizability, underscoring the potential of transformer-based multimodal learning to enhance treatment optimization and clinical QA efficiency.

Scientific Reports
Fujian Medical University (CN), Jiangsu Institute of Metrology (CN), Jiangsu Cancer Hospital (CN), Fujian Provincial Cancer Hospital (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 7%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.