Partial Discharge Characteristics in Electrical Tee Near Multi-layer Interface

To understand the relationship between the tree propagation near the interface in a multi-layer insulation system, which is likely to serve as electrical weak points, and partial discharge (PD) characteristics, PD patterns were measured for propagation of electrical trees in the Epoxy/Glass (EP/Glass) sample. When the maximum tree length is short, the number of detected partial discharges (PDs) in the composite-layer sample becomes smaller than that in the monolayer sample. Charges can easily move across the interface, which tends to act as an electrical weak point, resulting in a relatively small potential difference between the needle tip and the tree tip required for PD occurrence. Regardless of the presence or absence of an interface, the maximum PD charge also tended to increase as the maximum tree length became longer. This can be attributed to a larger potential difference between the needle electrode tip and the tree tip in longer trees, an increase in the number of tree branches leading to simultaneous PD events, or a combination of both factors.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Fundamentals and Materials
Published
2026-03-31
DOI
https://doi.org/10.1541/ieejfms.146.121
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Partial Discharge Characteristics in Electrical Tee Near Multi-layer Interface

Yoshinobu Murakami, Yoshitaka Miyaji, Yoshiyuki Hattori, Hiroki Shiota et al.
IEEJ Transactions on Fundamentals and Materials
High voltage insulation and dielectric phenomena
article

Partial Discharge Characteristics in Electrical Tee Near Multi-layer Interface

Yoshinobu Murakami, Yoshitaka Miyaji, Yoshiyuki Hattori, Hiroki Shiota, Toru Sawada, Takamasa Sato, Tomohiro Kawashima
article en

Abstract

To understand the relationship between the tree propagation near the interface in a multi-layer insulation system, which is likely to serve as electrical weak points, and partial discharge (PD) characteristics, PD patterns were measured for propagation of electrical trees in the Epoxy/Glass (EP/Glass) sample. When the maximum tree length is short, the number of detected partial discharges (PDs) in the composite-layer sample becomes smaller than that in the monolayer sample. Charges can easily move across the interface, which tends to act as an electrical weak point, resulting in a relatively small potential difference between the needle tip and the tree tip required for PD occurrence. Regardless of the presence or absence of an interface, the maximum PD charge also tended to increase as the maximum tree length became longer. This can be attributed to a larger potential difference between the needle electrode tip and the tree tip in longer trees, an increase in the number of tree branches leading to simultaneous PD events, or a combination of both factors.

IEEJ Transactions on Fundamentals and MaterialsVol. 146(4)
Toyohashi University of Technology (JP), Mitsubishi Electric (United States) (US)
Openalex Percentile: Top 7%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.