Impedance-aware enforcement of transient stability regions for grid-forming converters

As converter technology develops and rated capacities increase, the utilization of converters in power systems is becoming increasingly diverse and expanded. Furthermore, because of the fast control response of these converters, their contribution to power system stability is also increasing. There has been significant research on various approaches to utilizing grid-forming converters beyond microgrids and integrating them into large-scale power systems. In particular, there have been growing concerns about the decrease in stability caused by the low inertia resulting from the high penetration of renewable energy sources. As a possible solution to provide stability improvement, grid-forming converters have been gaining prominence. However, if the strength of the connected system or the angle stability are not considered, there is a possibility of a negative effect on the stable operation of the power system from these grid-forming converters. Therefore, if the topology of the connected system changes because of an event, the performance of the converter needs to be adjusted accordingly. In this paper, an impedance-aware auxiliary protection mechanism is presented for grid-forming converters to ensure stable operation under variations in the connected system impedance. An analysis of the admissible active power operating range based on the system impedance is conducted, and an auxiliary supervisory mechanism is implemented to constrain the converter power reference according to real time impedance variations. • Impedance-aware protection mitigates transient instability of grid-forming converters. • Active power reference is conservatively scaled based on observed impedance increase. • The approach adopts conservative impedance-based criteria for transient protection. • The mechanism relies solely on locally measured voltage and current signals. • Simulation results show enhanced transient stability under topology induced weak grids.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-03-31
DOI
https://doi.org/10.1016/j.egyr.2026.109214
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impedance-aware enforcement of transient stability regions for grid-forming converters

Minhan Yoon, Sungchul Hwang
Energy Reports
Microgrid Control and Optimization
article

Impedance-aware enforcement of transient stability regions for grid-forming converters

Minhan Yoon, Sungchul Hwang
article en

Abstract

As converter technology develops and rated capacities increase, the utilization of converters in power systems is becoming increasingly diverse and expanded. Furthermore, because of the fast control response of these converters, their contribution to power system stability is also increasing. There has been significant research on various approaches to utilizing grid-forming converters beyond microgrids and integrating them into large-scale power systems. In particular, there have been growing concerns about the decrease in stability caused by the low inertia resulting from the high penetration of renewable energy sources. As a possible solution to provide stability improvement, grid-forming converters have been gaining prominence. However, if the strength of the connected system or the angle stability are not considered, there is a possibility of a negative effect on the stable operation of the power system from these grid-forming converters. Therefore, if the topology of the connected system changes because of an event, the performance of the converter needs to be adjusted accordingly. In this paper, an impedance-aware auxiliary protection mechanism is presented for grid-forming converters to ensure stable operation under variations in the connected system impedance. An analysis of the admissible active power operating range based on the system impedance is conducted, and an auxiliary supervisory mechanism is implemented to constrain the converter power reference according to real time impedance variations. • Impedance-aware protection mitigates transient instability of grid-forming converters. • Active power reference is conservatively scaled based on observed impedance increase. • The approach adopts conservative impedance-based criteria for transient protection. • The mechanism relies solely on locally measured voltage and current signals. • Simulation results show enhanced transient stability under topology induced weak grids.

Energy ReportsVol. 15
Kwangwoon University (KR), Sunchon National University (KR)
Affordable and clean energy
Openalex Percentile: Top 31%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.