Optimization of the Fe(II)/O2/TPP system for ciprofloxacin degradation using response surface methodology

Ciprofloxacin (CIP) was used as the target pollutant to examine its degradation by the Fe(II)/O2/sodium tripolyphosphate (TPP) system. Based on single-factor experiments, a central composite design combined with response surface methodology was employed to systematically investigate the effects of Fe(II) concentration, TPP/Fe(II) molar ratio, and pH on CIP removal efficiency, and a quadratic polynomial regression model was established. The results showed that the order of influence of the three factors on CIP removal efficiency was TPP/Fe(II) molar ratio > pH > Fe(II) concentration. The model exhibited a good fit (R2 = 0.9563) and, thus, demonstrated accurate predictive capability. The optimized conditions were determined as follows: a TPP/Fe(II) molar ratio of 2.45, a pH of 7.0, and a Fe(II) concentration of 15.8 mmol l−1. Under these conditions, a CIP removal rate of 91.7% was achieved after 20 min of reaction. The experimentally optimized TPP/Fe(II) molar ratio closely agreed with the theoretical stoichiometric ratio (2:1) required for the formation of the dominant complex [Fe(II)(TPP)2]4−. Quenching experiments indicated that the reaction follows a consecutive single-electron reduction pathway (O2 → ·O2− → H2O2 → ·OH), with ·OH being the dominant reactive species for CIP degradation, as evidenced by inhibition rates of 91.9%, 91.7%, and 96.9% upon addition of tert-butanol, benzoquinone, and catalase, respectively. This study provides both a theoretical basis and a technical reference for the treatment of CIP-containing wastewater using the Fe(II)/O2/TPP system.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2026-04-01
DOI
https://doi.org/10.1063/5.0321648
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of the Fe(II)/O2/TPP system for ciprofloxacin degradation using response surface methodology

Haiyan Yu, Dan Sun, Meiyu Zhang, Rongcui Deng et al.
AIP Advances
Advanced oxidation water treatment
article

Optimization of the Fe(II)/O2/TPP system for ciprofloxacin degradation using response surface methodology

Haiyan Yu, Dan Sun, Meiyu Zhang, Rongcui Deng, Siqi Li
article en

Abstract

Ciprofloxacin (CIP) was used as the target pollutant to examine its degradation by the Fe(II)/O2/sodium tripolyphosphate (TPP) system. Based on single-factor experiments, a central composite design combined with response surface methodology was employed to systematically investigate the effects of Fe(II) concentration, TPP/Fe(II) molar ratio, and pH on CIP removal efficiency, and a quadratic polynomial regression model was established. The results showed that the order of influence of the three factors on CIP removal efficiency was TPP/Fe(II) molar ratio > pH > Fe(II) concentration. The model exhibited a good fit (R2 = 0.9563) and, thus, demonstrated accurate predictive capability. The optimized conditions were determined as follows: a TPP/Fe(II) molar ratio of 2.45, a pH of 7.0, and a Fe(II) concentration of 15.8 mmol l−1. Under these conditions, a CIP removal rate of 91.7% was achieved after 20 min of reaction. The experimentally optimized TPP/Fe(II) molar ratio closely agreed with the theoretical stoichiometric ratio (2:1) required for the formation of the dominant complex [Fe(II)(TPP)2]4−. Quenching experiments indicated that the reaction follows a consecutive single-electron reduction pathway (O2 → ·O2− → H2O2 → ·OH), with ·OH being the dominant reactive species for CIP degradation, as evidenced by inhibition rates of 91.9%, 91.7%, and 96.9% upon addition of tert-butanol, benzoquinone, and catalase, respectively. This study provides both a theoretical basis and a technical reference for the treatment of CIP-containing wastewater using the Fe(II)/O2/TPP system.

AIP AdvancesVol. 16(4)
Liaoning University of Technology (CN)
Department of Education of Liaoning Province, National College Students Innovation and Entrepreneurship Training Program
Clean water and sanitation
Openalex Percentile: Top 35%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.