Effect of Variable Jet Fan Speeds on Characteristics of Smoke Produced from Fires Inside Tunnels

Jet fans are commonly used in tunnels to provide ventilation and support evacuation during fire scenarios. These systems typically operate at constant speeds, which vary based on fan capacity, location, and spacing. The novelty of this study lies in evaluating the performance of variable-speed jet fans in comparison to constant speed jet fans and free ventilation in a full-scale tunnel, by investigating their influence on smoke velocity, temperature distribution, and visibility at various tunnel locations under different heat release rates (HRRs). All simulations were conducted using PyroSim as a Fire Dynamics Simulator (FDS), based on the real dimensions of the Ismailia Tunnel in Ismailia, Egypt. Variable-speed jet fans were configured to operate at incremental linear speeds starting at 4.8 m/s to reach 24 m/s using a series of five pairs of jet fans. An additional case was included, starting at 8 m/s and increasing to overcome the reverse smoke flow generated at the highest HRR, which ranged from 6 to 200 MW. The results presented that at a fixed HRR of 16 MW, the smoke movement at a height of 6.8 m decreased by 36–44% with variable-speed jet fans, and an 83% reduction under free ventilation compared to the constant-speed jet fans case. The maximum velocity difference between upper and lower tunnel sections reached 14.8 m/s at the highest HRR, decreasing by 19%, 43%, and 44% as HRR values decreased, particularly in the ventilation direction. For temperature distribution, the upper tunnel temperature decreased by 68% with constant-speed jet fans and by 35–42% with variable-speed jet fans. Regarding visibility, at an HRR of 16 MW, variable-speed jet fans reduced visibility by 7–13% at 300 m from the fire source relative to constant-speed fans, but improved visibility by 65% compared with free ventilation due to enhanced smoke extraction near the ceiling.

Authors

Institutions

Publication Details

Journal
Fire Technology
Published
2026-04-01
DOI
https://doi.org/10.1007/s10694-026-01883-6
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Variable Jet Fan Speeds on Characteristics of Smoke Produced from Fires Inside Tunnels

Y. A. Attai, M. M. Basha, M. Gamal, M. H. Shedid
Fire Technology
Fire dynamics and safety research
article

Effect of Variable Jet Fan Speeds on Characteristics of Smoke Produced from Fires Inside Tunnels

Y. A. Attai, M. M. Basha, M. Gamal, M. H. Shedid
article en

Abstract

Jet fans are commonly used in tunnels to provide ventilation and support evacuation during fire scenarios. These systems typically operate at constant speeds, which vary based on fan capacity, location, and spacing. The novelty of this study lies in evaluating the performance of variable-speed jet fans in comparison to constant speed jet fans and free ventilation in a full-scale tunnel, by investigating their influence on smoke velocity, temperature distribution, and visibility at various tunnel locations under different heat release rates (HRRs). All simulations were conducted using PyroSim as a Fire Dynamics Simulator (FDS), based on the real dimensions of the Ismailia Tunnel in Ismailia, Egypt. Variable-speed jet fans were configured to operate at incremental linear speeds starting at 4.8 m/s to reach 24 m/s using a series of five pairs of jet fans. An additional case was included, starting at 8 m/s and increasing to overcome the reverse smoke flow generated at the highest HRR, which ranged from 6 to 200 MW. The results presented that at a fixed HRR of 16 MW, the smoke movement at a height of 6.8 m decreased by 36–44% with variable-speed jet fans, and an 83% reduction under free ventilation compared to the constant-speed jet fans case. The maximum velocity difference between upper and lower tunnel sections reached 14.8 m/s at the highest HRR, decreasing by 19%, 43%, and 44% as HRR values decreased, particularly in the ventilation direction. For temperature distribution, the upper tunnel temperature decreased by 68% with constant-speed jet fans and by 35–42% with variable-speed jet fans. Regarding visibility, at an HRR of 16 MW, variable-speed jet fans reduced visibility by 7–13% at 300 m from the fire source relative to constant-speed fans, but improved visibility by 65% compared with free ventilation due to enhanced smoke extraction near the ceiling.

Fire TechnologyVol. 62(3)
University of Regina (CA), Helwan University (EG)
Helwan University
Affordable and clean energy
Openalex Percentile: Top 23%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Variable Jet Fan Speeds on Characteristics of Smoke Produced from Fires Inside Tunnels — Y. A. Attai, M. M. Basha, et al. · Fire Technology (2026) | TGRS Research Map | TGRS