Skin involvement is measurable in Dupuytrens’ disease: reliability of standardized skin elasticity measurements with Cutometer® MPA 580.

Introduction Skin involvement is a clinically relevant but insufficiently quantified feature of Dupuytren’s disease (DD). The Cutometer® MPA 580 offers an objective method to assess skin biomechanics, yet its reliability on healthy and DD-affected hands has not been examined using a hand-specific protocol. Methods In this cross-sectional study, two observers performed Cutometer® measurements on 31 DD-affected and 30 healthy hands using a standardized hand protocol. In DD patients, measurement sites were classified on skin involvement (fused vs non-fused). Reliability was assessed using ICC (2, 1), SEM, reproducibility coefficient (RC), and within-subject coefficient of variation (WSCV). Agreement was evaluated with Bland–Altman analysis. Differences between fused and non-fused sites were analysed for Uf (R0) and Ua/Uf (R2). Results Uf (R0) showed good intra-observer reliability on palmar regions in both healthy and DD hands. Reliability decreased on anatomically restricted areas, particularly along the ulnar side of the fourth digit, and inter-observer reliability was consistently lower. Ua/Uf (R2) showed acceptable intra-observer reliability for one observer, while inter-observer agreement remained poor. Absolute errors were smallest on the palm and highest in stiff or curved regions. Fused sites demonstrated lower maximal deformation (Uf) than non-fused skin, although interpretation is limited by the absence of precise anatomical site recording. Conclusion Using a hand-specific protocol, the Cutometer® provides reliable within-observer measurements on palmar skin, while digit measurements are less consistent. Differences between fused and non-fused skin support construct validity. Further standardization is recommended to support clinical and longitudinal use in hand evaluation.

Authors

Publication Details

Journal
Lirias
Published
2026-09-01
DOI
https://doi.org/10.1177/1758998326142026
Primary Topic
Dupuytren's Contracture and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Skin involvement is measurable in Dupuytrens’ disease: reliability of standardized skin elasticity measurements with Cutometer® MPA 580.

Philippe Tulkens, Mieke Anthonissen, Maarten Van Nuffel, Eric Van den Kerckhove et al.
Lirias
Dupuytren's Contracture and Treatments
article

Skin involvement is measurable in Dupuytrens’ disease: reliability of standardized skin elasticity measurements with Cutometer® MPA 580.

Philippe Tulkens, Mieke Anthonissen, Maarten Van Nuffel, Eric Van den Kerckhove, Caroline Meulyzer, Ilse Degreef
article en

Abstract

Introduction Skin involvement is a clinically relevant but insufficiently quantified feature of Dupuytren’s disease (DD). The Cutometer® MPA 580 offers an objective method to assess skin biomechanics, yet its reliability on healthy and DD-affected hands has not been examined using a hand-specific protocol. Methods In this cross-sectional study, two observers performed Cutometer® measurements on 31 DD-affected and 30 healthy hands using a standardized hand protocol. In DD patients, measurement sites were classified on skin involvement (fused vs non-fused). Reliability was assessed using ICC (2, 1), SEM, reproducibility coefficient (RC), and within-subject coefficient of variation (WSCV). Agreement was evaluated with Bland–Altman analysis. Differences between fused and non-fused sites were analysed for Uf (R0) and Ua/Uf (R2). Results Uf (R0) showed good intra-observer reliability on palmar regions in both healthy and DD hands. Reliability decreased on anatomically restricted areas, particularly along the ulnar side of the fourth digit, and inter-observer reliability was consistently lower. Ua/Uf (R2) showed acceptable intra-observer reliability for one observer, while inter-observer agreement remained poor. Absolute errors were smallest on the palm and highest in stiff or curved regions. Fused sites demonstrated lower maximal deformation (Uf) than non-fused skin, although interpretation is limited by the absence of precise anatomical site recording. Conclusion Using a hand-specific protocol, the Cutometer® provides reliable within-observer measurements on palmar skin, while digit measurements are less consistent. Differences between fused and non-fused skin support construct validity. Further standardization is recommended to support clinical and longitudinal use in hand evaluation.

Lirias
No poverty
Openalex Percentile: Top 71%
Dupuytren's Contracture and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.