Assessing the eco-centric light field to capture the light trespass of outdoor lighting

• Introduces an eco-centric approach to assess light trespass from outdoor lighting. • Combines light field, illuminance, and luminance methods in a field-based study. • Alternative luminaires reduced spill light into the terrain by up to 45%. • Louvres further reduced vertical and horizontal illuminance in adjacent areas. • Snow and cloud cover strongly amplified light propagation and diffuseness. Outdoor lighting supports human safety and visibility but also contributes to light pollution, which may disrupt ecological systems. This study applies an eco-centric lighting perspective, investigating the integration of three complementary lighting measurement methods using cubic light field measurements, vertical and horizontal illuminance, and luminance mapping. Three luminaire configurations, a conventional 4000 K road luminaire and two 2200 K alternatives (with and without louvre), were examined under varying environmental conditions (clear, cloudy, snowy clear and snowy cloudy). Measurements were conducted along a transect extending from the road into the adjacent terrain. Our findings demonstrate that, when combined, the three measurement methods capture both the spatio-directional spread and diffuseness qualities on the pavement together with the distal effects of the lighting. Horizontal and vertical illuminance measurements revealed that the alternative luminaires reduced spill light into the terrain by up to 45% compared to the conventional luminaire, with a further 16.6–19.5% reduction achieved using a louvre. Cubic light field measurements quantified the spatial characteristics of light, showing that light vector magnitude declined rapidly within 3–4 m from the luminaire, and diffuseness drastically changed under snowy conditions with an increase of 112%. Luminance mapping illustrated differences in contrast and relative visibility between luminaire types; overall, the conventional luminaire tended to stand out more against the background sky. This integrative approach enables a more nuanced understanding of how artificial lighting interacts with the surroundings and may contribute to the development of more eco-centric lighting strategies.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2026-03-31
DOI
https://doi.org/10.1016/j.buildenv.2026.114568
Primary Topic
Impact of Light on Environment and Health
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the eco-centric light field to capture the light trespass of outdoor lighting

Veronika Zaikina, Helga Iselin Wåseth, Sylvia Pont
Building and Environment
Impact of Light on Environment and Health
article

Assessing the eco-centric light field to capture the light trespass of outdoor lighting

Veronika Zaikina, Helga Iselin Wåseth, Sylvia Pont
article en

Abstract

• Introduces an eco-centric approach to assess light trespass from outdoor lighting. • Combines light field, illuminance, and luminance methods in a field-based study. • Alternative luminaires reduced spill light into the terrain by up to 45%. • Louvres further reduced vertical and horizontal illuminance in adjacent areas. • Snow and cloud cover strongly amplified light propagation and diffuseness. Outdoor lighting supports human safety and visibility but also contributes to light pollution, which may disrupt ecological systems. This study applies an eco-centric lighting perspective, investigating the integration of three complementary lighting measurement methods using cubic light field measurements, vertical and horizontal illuminance, and luminance mapping. Three luminaire configurations, a conventional 4000 K road luminaire and two 2200 K alternatives (with and without louvre), were examined under varying environmental conditions (clear, cloudy, snowy clear and snowy cloudy). Measurements were conducted along a transect extending from the road into the adjacent terrain. Our findings demonstrate that, when combined, the three measurement methods capture both the spatio-directional spread and diffuseness qualities on the pavement together with the distal effects of the lighting. Horizontal and vertical illuminance measurements revealed that the alternative luminaires reduced spill light into the terrain by up to 45% compared to the conventional luminaire, with a further 16.6–19.5% reduction achieved using a louvre. Cubic light field measurements quantified the spatial characteristics of light, showing that light vector magnitude declined rapidly within 3–4 m from the luminaire, and diffuseness drastically changed under snowy conditions with an increase of 112%. Luminance mapping illustrated differences in contrast and relative visibility between luminaire types; overall, the conventional luminaire tended to stand out more against the background sky. This integrative approach enables a more nuanced understanding of how artificial lighting interacts with the surroundings and may contribute to the development of more eco-centric lighting strategies.

Building and EnvironmentVol. 297
University of South-Eastern Norway (NO), Design Intelligence (United States) (US)
Kirke-, Utdannings- og Forskningsdepartementet
Sustainable cities and communities
Openalex Percentile: Top 20%
Impact of Light on Environment and Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.