Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery

Low cardiac output syndrome (LCOS) is a critical postoperative complication following cardiac surgery, leading to increased morbidity and mortality. This study aimed to evaluate the reliability of pulse contour analysis (PCA) using the Flotrac EV1000 system compared with transthoracic echocardiography (TTE) for Cardiac output (CO) measurement in LCOS patients. A single-center, prospective observational study was conducted on 50 patients with LCOS post-cardiac surgery. CO was measured using both TTE and PCA. Hemodynamic, clinical, and biochemical parameters were recorded, and correlations between CO measurements and clinical variables were assessed. The study population had a mean age of 52.2 ± 11.3 years, with 68% males and 60% classified as obese. Both PCA and TTE confirmed low cardiac output (PCA: 2.42 ± 0.56 L/min; TTE: 2.48 ± 0.58 L/min) with a very strong correlation between the two methods (r = 0.97, p < 0.001). Cardiac output positively correlated with body size, blood pressure, urine output, and central venous oxygen saturation, while negative correlations were noted with urea, creatinine, and lactate levels. These findings highlight the association between hemodynamic compromise and renal dysfunction in LCOS. Pulse contour analysis provides a reliable, continuous alternative to transthoracic echocardiography for cardiac output monitoring in LCOS patients post-cardiac surgery. Its real-time capability enhances clinical decision-making and supports timely interventions in the ICU setting.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Critical Care Medicine
Published
2026-04-01
DOI
https://doi.org/10.1007/s44349-026-00041-9
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery

Hatem H. Alatroush, Mamdouh A Kotb, Mohamed Abouel-wafa, Emad Eldeen Omar et al.
The Egyptian Journal of Critical Care Medicine
Hemodynamic Monitoring and Therapy
article

Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery

Hatem H. Alatroush, Mamdouh A Kotb, Mohamed Abouel-wafa, Emad Eldeen Omar, Sayed Gaber Ali
article en

Abstract

Low cardiac output syndrome (LCOS) is a critical postoperative complication following cardiac surgery, leading to increased morbidity and mortality. This study aimed to evaluate the reliability of pulse contour analysis (PCA) using the Flotrac EV1000 system compared with transthoracic echocardiography (TTE) for Cardiac output (CO) measurement in LCOS patients. A single-center, prospective observational study was conducted on 50 patients with LCOS post-cardiac surgery. CO was measured using both TTE and PCA. Hemodynamic, clinical, and biochemical parameters were recorded, and correlations between CO measurements and clinical variables were assessed. The study population had a mean age of 52.2 ± 11.3 years, with 68% males and 60% classified as obese. Both PCA and TTE confirmed low cardiac output (PCA: 2.42 ± 0.56 L/min; TTE: 2.48 ± 0.58 L/min) with a very strong correlation between the two methods (r = 0.97, p < 0.001). Cardiac output positively correlated with body size, blood pressure, urine output, and central venous oxygen saturation, while negative correlations were noted with urea, creatinine, and lactate levels. These findings highlight the association between hemodynamic compromise and renal dysfunction in LCOS. Pulse contour analysis provides a reliable, continuous alternative to transthoracic echocardiography for cardiac output monitoring in LCOS patients post-cardiac surgery. Its real-time capability enhances clinical decision-making and supports timely interventions in the ICU setting.

The Egyptian Journal of Critical Care MedicineVol. 13(1)
Cairo University (EG), Armed Forces College of Medicine (EG)
Good health and well-being
Openalex Percentile: Top 36%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery — Hatem H. Alatroush, Mamdouh A Kotb, et al. · The Egyptian Journal of Critical Care Medicine (2026) | TGRS Research Map | TGRS