Proposal of Management Method for Stator Winding of Hydro Generator by In-service Partial Discharge Diagnosis

In diagnostics of insulation degradation of stator winding of hydro generator, a high voltage (HV) is applied to the stator winding by HV applying device while the generator is disconnected from the power system to diagnose the degradation state of the stator winding. A method for estimating dielectric strength from the result of the off-line diagnosis is in practical use. On the other hand, in-service partial discharge (PD) diagnostics, which measures and evaluates the PD generated from the stator winding in service, do not require HV applying device and allows the frequency of measurement to be set freely, making it possible to determine the deterioration trend of winding and to expect early detection of winding faults. However, in-service PD diagnostics for stator windings of hydro generators have not been sufficiently implemented in Japanese electric power companies. Therefore, we examine the applicability of in-service PD diagnostics and propose management method for stator winding of hydropower generator by in-service PD diagnostics.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Power and Energy
Published
2026-03-31
DOI
https://doi.org/10.1541/ieejpes.146.301
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposal of Management Method for Stator Winding of Hydro Generator by In-service Partial Discharge Diagnosis

Satoru Miyazaki, Takashi Kuraishi
IEEJ Transactions on Power and Energy
High voltage insulation and dielectric phenomena
article

Proposal of Management Method for Stator Winding of Hydro Generator by In-service Partial Discharge Diagnosis

Satoru Miyazaki, Takashi Kuraishi
article en

Abstract

In diagnostics of insulation degradation of stator winding of hydro generator, a high voltage (HV) is applied to the stator winding by HV applying device while the generator is disconnected from the power system to diagnose the degradation state of the stator winding. A method for estimating dielectric strength from the result of the off-line diagnosis is in practical use. On the other hand, in-service partial discharge (PD) diagnostics, which measures and evaluates the PD generated from the stator winding in service, do not require HV applying device and allows the frequency of measurement to be set freely, making it possible to determine the deterioration trend of winding and to expect early detection of winding faults. However, in-service PD diagnostics for stator windings of hydro generators have not been sufficiently implemented in Japanese electric power companies. Therefore, we examine the applicability of in-service PD diagnostics and propose management method for stator winding of hydropower generator by in-service PD diagnostics.

IEEJ Transactions on Power and EnergyVol. 146(4)
Central Research Institute of Electric Power Industry (JP)
Affordable and clean energy
Openalex Percentile: Top 8%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Proposal of Management Method for Stator Winding of Hydro Generator by In-service Partial Discharge Diagnosis — Satoru Miyazaki, Takashi Kuraishi · IEEJ Transactions on Power and Energy (2026) | TGRS Research Map | TGRS