Picogram-Level Nanoplastic Analysis with Nanoelectromechanical System Fourier Transform Infrared Spectroscopy: NEMS-FTIR

We present a photothermal infrared spectroscopy-based approach for the chemical characterization and quantification of nanoplastics. By combining the high sensitivity of nanoelectromechanical systems (NEMS) with the wide spectral range and ubiquity of commercially available Fourier transform infrared (FTIR) spectrometers, NEMS-FTIR offers a time-efficient and cryogen-free option for the rapid, routine analysis of nanoplastics in aqueous samples. Polypropylene, polystyrene, and polyvinyl chloride nanoplastics with nominal diameters ranging from 54 to 262 nm were analyzed by NEMS-FTIR with limits of detection ranging from 101 to 353 pg, 1 order of magnitude lower than values reported for pyrolysis-gas chromatography-mass spectrometry of nanoplastics. The absorptance measured by NEMS-FTIR could be further converted to absolute sample mass using the attenuation coefficient, as demonstrated for polystyrene. Thanks to the wide spectral range of NEMS-FTIR, nanoplastic particles from different polymers could be readily identified, even when present in a mixture. The potential of NEMS-FTIR for the analysis of real samples was demonstrated by identifying the presence of nanoplastics released in water during tea brewing. Polyamide leachates in the form of fragments and smaller oligomers could be identified in the brewing water without sample preconcentration, even in the presence of an organic matrix. Accelerated aging of the nylon teabags under elevated temperature and UV radiation showed further release of polyamide over time.

Authors

Institutions

Publication Details

Journal
ACS Nano
Published
2026-04-01
DOI
https://doi.org/10.1021/acsnano.5c22099
Citations
1
Primary Topic
Polymer Nanocomposites and Properties
Type
article
Field-Weighted Citation Impact
11.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Picogram-Level Nanoplastic Analysis with Nanoelectromechanical System Fourier Transform Infrared Spectroscopy: NEMS-FTIR

Josiane Lafleur, Silvan Schmid, Eldira Sesto, Ariane Giesriegl et al.
1 citations
ACS Nano
Polymer Nanocomposites and Properties
11.18
article

Picogram-Level Nanoplastic Analysis with Nanoelectromechanical System Fourier Transform Infrared Spectroscopy: NEMS-FTIR

Josiane Lafleur, Silvan Schmid, Eldira Sesto, Ariane Giesriegl, Hajrudin Bešić, Johannes Hiesberger, Jelena Timarac-Popović, Niklas Luhmann
article en
1 citations

Abstract

We present a photothermal infrared spectroscopy-based approach for the chemical characterization and quantification of nanoplastics. By combining the high sensitivity of nanoelectromechanical systems (NEMS) with the wide spectral range and ubiquity of commercially available Fourier transform infrared (FTIR) spectrometers, NEMS-FTIR offers a time-efficient and cryogen-free option for the rapid, routine analysis of nanoplastics in aqueous samples. Polypropylene, polystyrene, and polyvinyl chloride nanoplastics with nominal diameters ranging from 54 to 262 nm were analyzed by NEMS-FTIR with limits of detection ranging from 101 to 353 pg, 1 order of magnitude lower than values reported for pyrolysis-gas chromatography-mass spectrometry of nanoplastics. The absorptance measured by NEMS-FTIR could be further converted to absolute sample mass using the attenuation coefficient, as demonstrated for polystyrene. Thanks to the wide spectral range of NEMS-FTIR, nanoplastic particles from different polymers could be readily identified, even when present in a mixture. The potential of NEMS-FTIR for the analysis of real samples was demonstrated by identifying the presence of nanoplastics released in water during tea brewing. Polyamide leachates in the form of fragments and smaller oligomers could be identified in the brewing water without sample preconcentration, even in the presence of an organic matrix. Accelerated aging of the nylon teabags under elevated temperature and UV radiation showed further release of polyamide over time.

ACS NanoVol. 20(14)
TU Wien (AT), Keysight Technologies (Austria) (AT)
Austrian Science Fund, Novo Nordisk Fonden, HORIZON EUROPE European Innovation Council
Affordable and clean energy
Openalex Percentile: Top 1%
Polymer Nanocomposites and Properties
11.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.