Design and performance of an illumination-based hyperspectral laparoscopic system

This paper presents the design and performance evaluation of an illumination-based hyperspectral imaging system for laparoscopic surgery, referred to as the HyperScope. Hyperspectral imaging holds significant promise in minimally invasive surgery due to its ability to capture detailed spectral signatures that can enhance intraoperative tissue characterization and improve surgical decision-making without the need for exogenous contrast agents. The presented HyperScope system integrates a supercontinuum laser source, a laser line tunable filter, and a laparoscope-coupled short-wave infrared camera, enabling spectral imaging across a broad wavelength range (450-1500 nm) with high spectral resolution and sufficient spatial resolution quantified through several metrics. The system's hardware and software components are optimized for clinical usability and spectral fidelity. Performance was assessed through a series of technical experiments, including spectral response characterization, a modulation transfer function measurement using the slanted-edge method, and an evaluation of distance compensation via pre-processing. The system achieves a spectral deviation of 0.16 nm (450-975 nm) and -1.23 nm (1000-1675 nm), with mean spatial resolutions of 0.02 mm in the visible range (450-800 nm) and 0.14 mm in the SWIR range (800-1500 nm). The results demonstrate consistent spectral accuracy, acceptable spatial resolution across the spectral range, and effective correction of distance-induced spectral variability using standard normal variate (SNV) processing. These findings support the potential of the HyperScope system for future integration into clinical MIS workflows, with applications in tumor detection, perfusion assessment, and real-time optical biopsies.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2026-04-01
DOI
https://doi.org/10.1063/5.0287851
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and performance of an illumination-based hyperspectral laparoscopic system

Henricus J. C. M. Sterenborg, Mark Witteveen, Theo Ruers
Review of Scientific Instruments
Optical Imaging and Spectroscopy Techniques
article

Design and performance of an illumination-based hyperspectral laparoscopic system

Henricus J. C. M. Sterenborg, Mark Witteveen, Theo Ruers
article en

Abstract

This paper presents the design and performance evaluation of an illumination-based hyperspectral imaging system for laparoscopic surgery, referred to as the HyperScope. Hyperspectral imaging holds significant promise in minimally invasive surgery due to its ability to capture detailed spectral signatures that can enhance intraoperative tissue characterization and improve surgical decision-making without the need for exogenous contrast agents. The presented HyperScope system integrates a supercontinuum laser source, a laser line tunable filter, and a laparoscope-coupled short-wave infrared camera, enabling spectral imaging across a broad wavelength range (450-1500 nm) with high spectral resolution and sufficient spatial resolution quantified through several metrics. The system's hardware and software components are optimized for clinical usability and spectral fidelity. Performance was assessed through a series of technical experiments, including spectral response characterization, a modulation transfer function measurement using the slanted-edge method, and an evaluation of distance compensation via pre-processing. The system achieves a spectral deviation of 0.16 nm (450-975 nm) and -1.23 nm (1000-1675 nm), with mean spatial resolutions of 0.02 mm in the visible range (450-800 nm) and 0.14 mm in the SWIR range (800-1500 nm). The results demonstrate consistent spectral accuracy, acceptable spatial resolution across the spectral range, and effective correction of distance-induced spectral variability using standard normal variate (SNV) processing. These findings support the potential of the HyperScope system for future integration into clinical MIS workflows, with applications in tumor detection, perfusion assessment, and real-time optical biopsies.

Review of Scientific InstrumentsVol. 97(4)
Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital (NL), University of Twente (NL)
Peace, Justice and strong institutions
Openalex Percentile: Top 28%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.