Diagnostic Accuracy of Transvaginal Ultrasound for Detecting Pelvic Adhesions and Predicting Surgical Time in Benign Gynecologic Surgery

OBJECTIVES: To assess the diagnostic accuracy of transvaginal ultrasound using the sliding sign for detecting pelvic adhesions and its correlation with operative time in laparoscopic surgery for benign gynecologic conditions. METHODS: A prospective, blinded diagnostic accuracy study was performed at Hospital San Juan de Dios, Santiago, Chile, from February 2022 to September 2023. Patients scheduled for benign laparoscopic surgery underwent preoperative transvaginal ultrasound within 30 days. Retrocervical and high sliding signs, adnexal mobility, and peritoneal pseudocysts were evaluated. Laparoscopic findings were the reference standard. Diagnostic accuracy and operative times were analyzed. RESULTS: A total of 202 patients were included (mean age 36 years). Pelvic adhesions were identified intraoperatively in 63 patients (31.2%), mainly loose adhesions (28.7%). The retrocervical sliding sign showed the best performance for Pouch of Douglas (POD) obliteration (sensitivity 65%, specificity 96%, accuracy 93.5%). Adnexal mobility tests had moderate sensitivity (53-64%) but high specificity (>90%). The high sliding sign was poorly sensitive (16%) but high specificity (95%). Negative sliding signs were associated with longer operative time (139 versus 60 minutes; p < .01). Obliteration of the POD was strongly linked to chronic pelvic pain, infertility, and deep infiltrating endometriosis (p < .01). A history of laparotomy was a significant risk factor for adhesions (38.3% versus 13.6%; p < .001). CONCLUSION: Transvaginal ultrasound, particularly the sliding sign, is a reliable tool for excluding pelvic adhesions. Its high specificity and negative predictive value support its routine use in preoperative evaluation and surgical planning for benign gynecologic procedures.

Authors

Institutions

Publication Details

Journal
Journal of Ultrasound in Medicine
Published
2026-04-01
DOI
https://doi.org/10.1002/jum.70250
Citations
2
Primary Topic
Intestinal and Peritoneal Adhesions
Type
article
Field-Weighted Citation Impact
52.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Accuracy of Transvaginal Ultrasound for Detecting Pelvic Adhesions and Predicting Surgical Time in Benign Gynecologic Surgery

Cristian Morales, Rodrigo Assar, Claudia Hinojosa, J. Alcazar et al.
2 citations
Journal of Ultrasound in Medicine
Intestinal and Peritoneal Adhesions
52.30
article

Diagnostic Accuracy of Transvaginal Ultrasound for Detecting Pelvic Adhesions and Predicting Surgical Time in Benign Gynecologic Surgery

Cristian Morales, Rodrigo Assar, Claudia Hinojosa, J. Alcazar, Emilia Crovo, Valentina Borquez, Sofia Morales
article en
2 citations

Abstract

OBJECTIVES: To assess the diagnostic accuracy of transvaginal ultrasound using the sliding sign for detecting pelvic adhesions and its correlation with operative time in laparoscopic surgery for benign gynecologic conditions. METHODS: A prospective, blinded diagnostic accuracy study was performed at Hospital San Juan de Dios, Santiago, Chile, from February 2022 to September 2023. Patients scheduled for benign laparoscopic surgery underwent preoperative transvaginal ultrasound within 30 days. Retrocervical and high sliding signs, adnexal mobility, and peritoneal pseudocysts were evaluated. Laparoscopic findings were the reference standard. Diagnostic accuracy and operative times were analyzed. RESULTS: A total of 202 patients were included (mean age 36 years). Pelvic adhesions were identified intraoperatively in 63 patients (31.2%), mainly loose adhesions (28.7%). The retrocervical sliding sign showed the best performance for Pouch of Douglas (POD) obliteration (sensitivity 65%, specificity 96%, accuracy 93.5%). Adnexal mobility tests had moderate sensitivity (53-64%) but high specificity (>90%). The high sliding sign was poorly sensitive (16%) but high specificity (95%). Negative sliding signs were associated with longer operative time (139 versus 60 minutes; p < .01). Obliteration of the POD was strongly linked to chronic pelvic pain, infertility, and deep infiltrating endometriosis (p < .01). A history of laparotomy was a significant risk factor for adhesions (38.3% versus 13.6%; p < .001). CONCLUSION: Transvaginal ultrasound, particularly the sliding sign, is a reliable tool for excluding pelvic adhesions. Its high specificity and negative predictive value support its routine use in preoperative evaluation and surgical planning for benign gynecologic procedures.

Journal of Ultrasound in Medicine
Universidad del Desarrollo (CL), Hospital Quirónsalud Barcelona (ES), Hospital San Juan de Dios (CL), University of Chile (CL)
Good health and well-being
Openalex Percentile: Top 0%
Intestinal and Peritoneal Adhesions
52.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.