Out-of-Plane Skew Effects on the Cyclic Performance of Column-Tree Steel Moment Connections

) up to a 0.04 rad story drift ratio. However, the introduction of beam skew resulted in a gradual reduction in energy dissipation capacity, with the total dissipated energy decreasing by 2.9-8.9% at a 30° skew. Notably, the inelastic energy component was more sensitive to the skew than the frictional components, exhibiting a maximum reduction of 15.4%. While out-of-plane skew disrupted the symmetry of stress triaxiality and plastic strain at the beam-to-column interface, the overall fracture susceptibility was not significantly exacerbated up to 30°. Furthermore, column twisting remained within a negligible range (below 0.5°), and its impact on global stability was limited. Despite the general stability, a premature bolted splice failure was observed in deep beam configurations at a 30° skew during the 0.05 rad drift cycles. Based on these findings, it is concluded that column-tree connections with an out-of-plane skew up to 30° are viable; however, a design limit of 20° is recommended for deep beam configurations to ensure structural integrity under extreme cyclic demands.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-03-31
DOI
https://doi.org/10.3390/ma19071401
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Out-of-Plane Skew Effects on the Cyclic Performance of Column-Tree Steel Moment Connections

Jong-Kook Hong, Geonwoo Kim
Materials
Structural Load-Bearing Analysis
article

Out-of-Plane Skew Effects on the Cyclic Performance of Column-Tree Steel Moment Connections

Jong-Kook Hong, Geonwoo Kim
article en

Abstract

) up to a 0.04 rad story drift ratio. However, the introduction of beam skew resulted in a gradual reduction in energy dissipation capacity, with the total dissipated energy decreasing by 2.9-8.9% at a 30° skew. Notably, the inelastic energy component was more sensitive to the skew than the frictional components, exhibiting a maximum reduction of 15.4%. While out-of-plane skew disrupted the symmetry of stress triaxiality and plastic strain at the beam-to-column interface, the overall fracture susceptibility was not significantly exacerbated up to 30°. Furthermore, column twisting remained within a negligible range (below 0.5°), and its impact on global stability was limited. Despite the general stability, a premature bolted splice failure was observed in deep beam configurations at a 30° skew during the 0.05 rad drift cycles. Based on these findings, it is concluded that column-tree connections with an out-of-plane skew up to 30° are viable; however, a design limit of 20° is recommended for deep beam configurations to ensure structural integrity under extreme cyclic demands.

MaterialsVol. 19(7)
Chonnam National University (KR), Sunchon National University (KR)
Affordable and clean energy
Openalex Percentile: Top 29%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.